Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline

被引:80
|
作者
Lakard, Boris [1 ]
Magnin, Delphine [2 ]
Deschaume, Olivier [2 ]
Vanlancker, Guilhem [2 ]
Glinel, Marine [2 ]
Demoustier-Champagne, Sophie [2 ]
Nysten, Bernard [2 ]
Jonas, Alain M. [2 ]
Bertrand, Patrick [2 ]
Yunus, Sami [2 ]
机构
[1] Univ Franche Comte, Inst UTINAM, UMR CNRS 6213, Equipe Mat & Surfaces Struct, F-25030 Besancon, France
[2] Catholic Univ Louvain, Inst Condensed Matter & Nanosci, B-1348 Louvain, Belgium
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 10期
关键词
Urea biosensor; Enzyme immobilization; Conducting polymer; Polyaniline; Polyelectrolyte multilayers; Polysaccharides; NANOPOROUS ALUMINA MEMBRANES; INTEGRATED THERMAL BIOSENSOR; ELECTROINACTIVE POLYPYRROLE; PH; IMMOBILIZATION; SURFACE; SENSOR; FILMS; TRANSDUCER; PENICILLIN;
D O I
10.1016/j.bios.2011.04.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANE), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L-1 urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4139 / 4145
页数:7
相关论文
共 50 条
  • [31] Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate
    Saeedfar, Kasra
    Heng, Lee Yook
    Ling, Tan Ling
    Rezayi, Majid
    SENSORS, 2013, 13 (12) : 16851 - 16866
  • [32] Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection
    Kalkan, Zeycan
    Yence, Merve
    Turk, Fatih
    Bektas, Tamer U.
    Ozturk, Soner
    Surdem, Sedat
    Yildirim-Tirgil, Nimet
    ELECTROANALYSIS, 2022, 34 (01) : 33 - 42
  • [33] Construction of a potentiometric biosensor for monitoring urea during peritoneal dialysis
    Cunningham, DD
    SENSOR LETTERS, 2004, 2 (3-4) : 217 - 220
  • [34] Analysis of Potential Applicability of the Potentiometric Urea Biosensor to Real Samples
    Flores, Rafaela O.
    Silva, Livia Maria da C.
    Melo, Ariana F.
    Salgado, Andrea M.
    ICHEAP-11: 11TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-4, 2013, 32 : 367 - 372
  • [35] Detection of organophosphorus pesticides using potentiometric enzymatic membrane biosensor based on methylcellulose immobilization
    College of Resources and Environment, Southwest University, Chongqing 400716, China
    不详
    不详
    不详
    不详
    Anal. Sci., 4 (511-515):
  • [36] Detection of Organophosphorus Pesticides Using Potentiometric Enzymatic Membrane Biosensor Based on Methylcellulose Immobilization
    Jinzhong Zhang
    Aimin Luo
    Ping Liu
    Shaping Wei
    Guomin Wang
    Shiqiang Wei
    Analytical Sciences, 2009, 25 : 511 - 515
  • [37] Detection of Organophosphorus Pesticides Using Potentiometric Enzymatic Membrane Biosensor Based on Methylcellulose Immobilization
    Zhang, Jinzhong
    Luo, Aimin
    Liu, Ping
    Wei, Shaping
    Wang, Guomin
    Wei, Shiqiang
    ANALYTICAL SCIENCES, 2009, 25 (04) : 511 - 515
  • [38] ENZYME UREA BIOSENSOR BASED ON A MODIFIED POTENTIOMETRIC PVC-NONACTIN MEMBRANE-ELECTRODE FOR ASSAY OF UREA IN BLOOD
    BUTT, SB
    CAMMANN, K
    ANALYTICAL LETTERS, 1992, 25 (09) : 1597 - 1615
  • [39] Urea enzymatic hydrolysis reaction: Optimization by response surface methodology based on potentiometric measurements
    Deyhimi, Farzad
    Bajalan, Maryam
    BIOELECTROCHEMISTRY, 2008, 74 (01) : 176 - 182
  • [40] Development of potentiometric micro-sized urea biosensor based on urease-dextran complex
    Vardar, G.
    Yapaoz, M. Altikatoglu
    FEBS OPEN BIO, 2018, 8 : 167 - 167