A thermal network model for hydrocarbon heat pump systems: A coupling analysis of configuration, working condition, and refrigeration distribution

被引:8
|
作者
Liang, Jierong [1 ,2 ]
Zhu, Tingting [2 ,3 ]
Sun, Li [4 ]
Wang, Hao [5 ]
Li, Tingxun [1 ]
机构
[1] Sun Yat Sen Univ, Sch Intelligent Syst Engn, West Xingan Rd 135, Guangzhou 510275, Peoples R China
[2] Tech Univ Denmark, Dept Civil & Mech Engn, Sect Thermal Energy, Nils Koppels, DK-2800 Lyngby, Denmark
[3] Univ Twente, Fac Engn Technol ET, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[4] Hohai Univ, Coll Mech & Elect Engn, Changzhou 213022, Peoples R China
[5] Guangdong Shenling Environm Syst Co Ltd, Xinglong 10th Rd 8, Foshan 528313, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump model; Resistance-capacitance network; Hydrocarbon; Charge reduction; Refrigerant distribution; AIR-CONDITIONER; PRESSURE-DROP; 2-PHASE FLOW; MASS-DISTRIBUTION; FRICTION CHARACTERISTICS; CHARGE OPTIMIZATION; GENERAL CORRELATION; HORIZONTAL TUBES; RISK-ASSESSMENT; SMOOTH TUBES;
D O I
10.1016/j.enconman.2022.115908
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ambition of zero emission neighborhood has been set out to operate the building components with zero life cycle greenhouse gas emissions. Hydrocarbon heat pumps as the building components with nearly zero greenhouse gas emissions are faced with the problem of simultaneously reducing refrigerant charges and maintaining competitive capacities. These must be resolved by formulating an effective modeling tool for detailed design and optimization. To develop a resistance-capacitance network model, interdisciplinary knowledge (including graph theory, heat and mass transfer, local moving boundary modeling, and algebraic multigrid) is integrated. The model simultaneously considers heat exchanger circuitries with a high detail level and component behaviors at a holistic system level. Based on experimental validation, the model's error is similar to 10%. In an R290 heat pump case study, the coupling mechanism of the system's configuration, working conditions, and refrigerant distribution are analyzed. Results indicate that the refrigerant charge can be reduced by 11.6% at the expense of a 4.2% reduction in the coefficient of performance, by varying the compressor displacement alone. In response to the variation in the system's refrigerant, 46.8%, 7.85%, and 44.2% of the total amount of refrigerants are allocated to the condenser, evaporator, and compressor, respectively. The distribution of the refrigerant quality in the heat exchanger is also visualized to indicate the direction of refrigerant reduction.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A statistical analysis on market-available solar thermal heat pump systems
    Ruschenburg, Joern
    Herkel, Sebastian
    Henning, Hans-Martin
    SOLAR ENERGY, 2013, 95 : 79 - 89
  • [22] Determining parameters of rock-soil thermal properties in thermal response test of ground-coupled heat pump under working condition of transient heat flow
    Zhang, Changxing
    Guo, Zhanjun
    Liu, Yufeng
    Sun, Shicai
    Peng, Donggen
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2014, 30 (12): : 192 - 199
  • [23] Design of heat transfer network analogy model for complex thermal systems
    Zvizdic, D
    Ruzinski, N
    PROCEEDINGS OF THE 6TH INTERNATIONAL DESIGN CONFERENCE: DESIGN 2000, 2000, : 721 - 726
  • [24] Thermal Network Model for Variable Flow Ground Heat Exchanger Systems
    Ruan, Wei
    Horton, William Travis
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 550 - 557
  • [25] Analysis of Influence of Air Source Heat Pump Load on Distribution Network Power Quality
    Bi, Hailian
    Che, Yanbo
    Xue, Siyuan
    He, Wei
    Liu, Liangliang
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 3326 - 3331
  • [26] Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review
    Xiong, Tong
    Liu, Guoqiang
    Gao, Qiang
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF BUILDING ENGINEERING, 2023, 64
  • [27] Two-phase flow distribution in parallel flow mini/micro-channel heat exchangers for refrigeration and heat pump systems: A comprehensive review
    Xiong, Tong
    Liu, Guoqiang
    Huang, Shenjie
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2022, 201
  • [28] Maximizing thermal response in latent heat thermal energy storage systems: A comprehensive study of wavy fin configuration and distribution
    Benaissa, Mhamed
    Aljibori, Hakim S. Sultan
    Abed, Azher M.
    Mahdi, Jasim M.
    Mohammed, Hayder I.
    Younis, Obai
    Talebizadehsardari, Pouyan
    Ben Khedher, Nidhal
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [29] Analysis of the thermal interference between ground source heat pump systems in dense neighborhoods
    Fasci, Maria Letizia
    Lazzarotto, Alberto
    Acuna, Jose
    Claesson, Joachim
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (08) : 1069 - 1080
  • [30] A TRNSYS-based simulation framework for the analysis of solar thermal and heat pump systems
    Jonas D.
    Theis D.
    Felgner F.
    Frey G.
    Applied Solar Energy, 2017, 53 (2) : 126 - 137