A thermal network model for hydrocarbon heat pump systems: A coupling analysis of configuration, working condition, and refrigeration distribution

被引:8
|
作者
Liang, Jierong [1 ,2 ]
Zhu, Tingting [2 ,3 ]
Sun, Li [4 ]
Wang, Hao [5 ]
Li, Tingxun [1 ]
机构
[1] Sun Yat Sen Univ, Sch Intelligent Syst Engn, West Xingan Rd 135, Guangzhou 510275, Peoples R China
[2] Tech Univ Denmark, Dept Civil & Mech Engn, Sect Thermal Energy, Nils Koppels, DK-2800 Lyngby, Denmark
[3] Univ Twente, Fac Engn Technol ET, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[4] Hohai Univ, Coll Mech & Elect Engn, Changzhou 213022, Peoples R China
[5] Guangdong Shenling Environm Syst Co Ltd, Xinglong 10th Rd 8, Foshan 528313, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump model; Resistance-capacitance network; Hydrocarbon; Charge reduction; Refrigerant distribution; AIR-CONDITIONER; PRESSURE-DROP; 2-PHASE FLOW; MASS-DISTRIBUTION; FRICTION CHARACTERISTICS; CHARGE OPTIMIZATION; GENERAL CORRELATION; HORIZONTAL TUBES; RISK-ASSESSMENT; SMOOTH TUBES;
D O I
10.1016/j.enconman.2022.115908
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ambition of zero emission neighborhood has been set out to operate the building components with zero life cycle greenhouse gas emissions. Hydrocarbon heat pumps as the building components with nearly zero greenhouse gas emissions are faced with the problem of simultaneously reducing refrigerant charges and maintaining competitive capacities. These must be resolved by formulating an effective modeling tool for detailed design and optimization. To develop a resistance-capacitance network model, interdisciplinary knowledge (including graph theory, heat and mass transfer, local moving boundary modeling, and algebraic multigrid) is integrated. The model simultaneously considers heat exchanger circuitries with a high detail level and component behaviors at a holistic system level. Based on experimental validation, the model's error is similar to 10%. In an R290 heat pump case study, the coupling mechanism of the system's configuration, working conditions, and refrigerant distribution are analyzed. Results indicate that the refrigerant charge can be reduced by 11.6% at the expense of a 4.2% reduction in the coefficient of performance, by varying the compressor displacement alone. In response to the variation in the system's refrigerant, 46.8%, 7.85%, and 44.2% of the total amount of refrigerants are allocated to the condenser, evaporator, and compressor, respectively. The distribution of the refrigerant quality in the heat exchanger is also visualized to indicate the direction of refrigerant reduction.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Numerical investigation on the factors influencing the temperature distribution of photovoltaic/thermal (PVT) evaporator/condenser for heat pump systems
    Bisengimana, Emmanuel
    Zhou, Jinzhi
    Binama, Maxime
    Yuan, Yanping
    RENEWABLE ENERGY, 2022, 194 : 885 - 901
  • [42] A MULTIOBJECTIVE OPTIMIZATION APPROACH TO A DESIGN PROBLEM OF HEAT INSULATION FOR THERMAL DISTRIBUTION PIPING NETWORK SYSTEMS
    ITO, K
    AKAGI, S
    NISHIKAWA, M
    JOURNAL OF MECHANISMS TRANSMISSIONS AND AUTOMATION IN DESIGN-TRANSACTIONS OF THE ASME, 1983, 105 (02): : 206 - 213
  • [43] Model Predictive Control Design for Unlocking the Energy Flexibility of Heat Pump and Thermal Energy Storage Systems
    Tang, Weihong
    Li, Yun
    Walker, Shalika
    Keviczky, Tamas
    2024 IEEE CONFERENCE ON CONTROL TECHNOLOGY AND APPLICATIONS, CCTA 2024, 2024, : 433 - 439
  • [44] An electrochemical-thermal coupling model for heat generation analysis of prismatic lithium battery
    Ren, Honglei
    Jia, Li
    Dang, Chao
    Qi, Zhuoling
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [45] Efficacy of coupling heat recovery ventilation and fan coil systems in improving the indoor air quality and thermal comfort condition
    Jahanbin A.
    Energy and Built Environment, 2022, 3 (04): : 478 - 495
  • [46] A mathematical model and thermal performance analysis of single-well circulation (SWC) coupled ground source heat pump (GSHP) systems
    Tu, Kun
    Wu, Qiang
    Sun, Haizhou
    APPLIED THERMAL ENGINEERING, 2019, 147 : 473 - 481
  • [47] Coupling a Borehole Thermal Model and MT3DMS to Simulate Dynamic Ground Source Heat Pump Efficiency
    Zong, Yifei
    Valocchi, Albert J.
    Lin, Yu-Feng F.
    GROUNDWATER, 2023, 61 (02) : 237 - 244
  • [48] Uncertainty Level of Voltage in Distribution Network: An Analysis Model With Elastic Net and Application in Storage Configuration
    Chen, Pengwei
    Tao, Shun
    Xiao, Xiangning
    Li, Lu
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) : 2563 - 2573
  • [49] Analysis of thermocline thermal energy storage systems with generic initial condition algebraic model
    Bonanos, Aristides M.
    Votyakov, Evgeny V.
    SOLAR ENERGY, 2021, 213 : 154 - 162
  • [50] Simulation and performance analysis of combined parallel solar thermal and ground or air source heat pump systems
    Jonas, Danny
    Frey, Georg
    Theis, Danjana
    SOLAR ENERGY, 2017, 150 : 500 - 511