Analysis of Influence of Air Source Heat Pump Load on Distribution Network Power Quality

被引:0
|
作者
Bi, Hailian [1 ]
Che, Yanbo [1 ]
Xue, Siyuan [1 ]
He, Wei [2 ]
Liu, Liangliang [1 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
[2] State Grid Jiangxi Elect Power Res Inst, Nanchang 330096, Jiangxi, Peoples R China
关键词
electric heating equipment; air source heat pump (ASHP); voltage sag; power quality; emission characteristics;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Air source heat pump (ASHP) is common electric heating equipment in the "coal to electricity" project in China. ASHPs connected into the power grid can cause reactive power shortage, voltage sag, harmonic current violation and other power quality problems. Based on the typical topological structure of ASHPs and the mechanism of power quality problems, the simulation model of ASHP is built, and the power quality emission characteristics of ASHP connected to distribution network are studied. The power quality problems caused by ASHP connected to distribution network are measured and analyzed. The results of simulation and measurement analysis show that fixed frequency ASHPs will generate large reactive power when start, and will cause voltage sag. And the harmonic violation problem will occur when variable frequency ASHP runs.
引用
收藏
页码:3326 / 3331
页数:6
相关论文
共 50 条
  • [1] Analysis of Power Quality Problems in Large-Scale Application of Air-Source Heat Pump
    Zheng Z.
    Che Y.
    Bi H.
    Wu D.
    He W.
    Energy Engineering: Journal of the Association of Energy Engineering, 2022, 119 (02): : 637 - 651
  • [2] Influence from the location of air source heat pump or cooling tower for air conditioning load of high rise buildings
    Zhang, JT
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 82 - 86
  • [3] Temperature distribution of air source heat pump barn with different air flow
    He, X.
    Li, J. C.
    Zhao, G. Q.
    2016 INTERNATIONAL CONFERENCE ON NEW ENERGY AND FUTURE ENERGY SYSTEM (NEFES 2016), 2016, 40
  • [4] The Influence of Dynamic Load on Ground Source Heat Pump System Performance
    Wang, Jingjing
    Zeng, Yunfan
    Tian, Huifang
    Wu, Zhou
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1470 - +
  • [5] Analysis and optimization of heating load density for an air heat pump
    Bi, Yue-Hong
    Shang, Chun-Ge
    Wang, Xin-Hong
    Liu, Yun
    Beijing Gongye Daxue Xuebao / Journal of Beijing University of Technology, 2009, 35 (SUPPL.): : 74 - 78
  • [6] DEMAND RESPONSE CONSIDERING AIR SOURCE HEAT PUMP LOAD AGGREGATED PARTICIPATION
    Liang, Haiping
    Xie, Xin
    Li, Shihang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (08): : 273 - 280
  • [7] Analysis of the Influence of Distributed Photovoltaic Power Generation Network on Distribution Network Security and Power Quality
    Hou, Laiyun
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC, CONTROL AND AUTOMATION ENGINEERING (MECAE 2018), 2018, 149 : 671 - 674
  • [8] Source-grid-load-storage interactive power quality characteristic of active distribution network
    Li, Yahui
    Lou, Jie
    Sun, Kaiqi
    Li, Ke-Jun
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [9] Influence of airflow rates on air source heat pump operating parameters
    Sezen, Kutbay
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [10] Long-term operation analysis of a ground source heat pump with an air source heat pump as an auxiliary heat source in a warm region
    Kaneko, Chika
    Yoshinaga, Mika
    ENERGY AND BUILDINGS, 2023, 289