Analysis of Influence of Air Source Heat Pump Load on Distribution Network Power Quality

被引:0
|
作者
Bi, Hailian [1 ]
Che, Yanbo [1 ]
Xue, Siyuan [1 ]
He, Wei [2 ]
Liu, Liangliang [1 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
[2] State Grid Jiangxi Elect Power Res Inst, Nanchang 330096, Jiangxi, Peoples R China
关键词
electric heating equipment; air source heat pump (ASHP); voltage sag; power quality; emission characteristics;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Air source heat pump (ASHP) is common electric heating equipment in the "coal to electricity" project in China. ASHPs connected into the power grid can cause reactive power shortage, voltage sag, harmonic current violation and other power quality problems. Based on the typical topological structure of ASHPs and the mechanism of power quality problems, the simulation model of ASHP is built, and the power quality emission characteristics of ASHP connected to distribution network are studied. The power quality problems caused by ASHP connected to distribution network are measured and analyzed. The results of simulation and measurement analysis show that fixed frequency ASHPs will generate large reactive power when start, and will cause voltage sag. And the harmonic violation problem will occur when variable frequency ASHP runs.
引用
收藏
页码:3326 / 3331
页数:6
相关论文
共 50 条
  • [21] Analysis of the influence of heat source well parameters on pumping temperature of groundwater source heat pump
    Min, Wu
    3RD INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 631
  • [22] Experimental Investigation of Frost Formation Influence on an Air Source Heat Pump Evaporator
    Kropas, Tomas
    Streckiene, Giedre
    Bielskus, Juozas
    ENERGIES, 2021, 14 (18)
  • [23] Research on the ultra-short-time load prediction method of air source heat pump considering the input of neural network
    Xu Zhenhua
    Zhao Xiangyang
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 260 - 263
  • [24] Exergy Analysis of Air-source Heat Pump Water Heater
    Mi Bingjie
    Luo Qinghai
    Chen Guojie
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 197 - 202
  • [25] Performance analysis of air source heat pump system for office building
    Dongwon Han
    Young Soo Chang
    Yongchan Kim
    Journal of Mechanical Science and Technology, 2016, 30 : 5257 - 5268
  • [26] Performance analysis of air source heat pump system for office building
    Han, Dongwon
    Chang, Young Soo
    Kim, Yongchan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (11) : 5257 - 5268
  • [27] Design and analysis of thermoacoustic air source heat pump water heaters
    Prashantha, B. G.
    Kuwar, Yogendra Vasantrao
    Narasimham, G. S. V. L.
    Seetharamu, S.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2024, 32 (01)
  • [28] Application and analysis of a new air-source heat pump in Beijing
    Huang, XW
    Wang, RX
    Li, DY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 282 - 289
  • [29] Experimental investigation of an Air Source Heat Pump
    Talpiga, Mugurel Florin
    Iordache, Florin
    Mandric, Eugen
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT (EENVIRO 2018), 2019, 85
  • [30] Performance analysis of heat pump based on a new solar air-source heat pump heating system
    Liang, Caihua
    Zhang, Xiaosong
    Zhu, Xia
    Li, Xiuwei
    Journal of Southeast University (English Edition), 2010, 26 (02) : 227 - 231