Reliability of medial temporal lobe volume measurements using reformatted 3D images

被引:56
|
作者
Bartzokis, G
Altshuler, LL
Greider, T
Curran, J
Keen, B
Dixon, WJ
机构
[1] W Los Angeles Vet Affairs Med Ctr, Res Serv, Los Angeles, CA 90073 USA
[2] Univ Calif Los Angeles, Dept Psychiat, Los Angeles, CA 90074 USA
[3] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90074 USA
[4] Gen Elect Med Syst, Milwaukee, WI 53188 USA
关键词
magnetic resonance imaging; methodology; temporal horn; hippocampus; amygdala;
D O I
10.1016/S0925-4927(98)00007-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The study assessed whether standardizing the angle of image display and controlling for head position in three planes affects the scan-rescan reliability of medial temporal lobe volume measures when very thin (1.5 mm) slices are used. Five volunteers were scanned two times oil consecutive days. A three-dimensional MRI sequence acquired whole brain data in 1.4 mm thick coronal slices. The data were displayed as 1.5 mm thick images and were rated both in the originally acquired coronal plane, and after reformatting to correct for head tilt and display the brain in the coronal plane perpendicular to the long axis of the left anterior hippocampus. One rater measured five brain regions (temporal lobe, anterior and posterior hippocampus, amygdala, and temporal horn) on the left and right sides of the two non-reformatted and two reformatted scans to obtain inter-scan variance. Furthermore, most scans were remeasured, to obtain 'reread' variances. All data were log-transformed in order to produce comparable variability across brain regions of different sizes. For all the regions, except the temporal horn, the non-reformatted scans showed significantly larger scan-rescan variability than the reformatted scans. A typical standard deviation for a non-reformatted pair of scans was 0.10, corresponding to 26% error, while a typical value for a reformatted pair of scans was 0.04, corresponding to 10% error. For all the regions, the reread data (intra-rater reliability) gave similar results for both reformatted and non-reformatted images with similar standard deviations (typical value for reread standard deviation was 0.020, corresponding to 5% error). The data suggest that, even when very thin slices are acquired, volume measurement accuracy of gray matter structures in the temporal lobe is considerably improved by controlling for image orientation in three planes. For these structures, the sample size needed to detect a small (5%) within-subject volume change would be halved if reformatted images were used. Image contrast is an additional important factor since the reformatted T-1 weighted images used in this study, which have suboptimal CSF/brain contrast, worsened measurement accuracy in the temporal horn. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 50 条
  • [21] Detection and Quantification of Tunneling Nanotubes Using 3D Volume View Images
    Valappil, Deepak Kunhi
    Raghavan, Abinaya
    Nath, Sangeeta
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (186):
  • [22] 3D COLOR VISUALIZATION OF LABEL IMAGES USING VOLUME RENDERING TECHNIQUES
    VANDENHOUTEN, R
    KOTTENHOFF, R
    GREBE, R
    MEDICAL INFORMATICS, 1995, 20 (02): : 149 - 159
  • [23] Temporal horn index and volume of medial temporal lobe atrophy using a new semiautomated method for rapid and precise assessment
    Giesel, F. L.
    Hahn, H. K.
    Thomann, P. A.
    Widjaja, E.
    Wignall, E.
    von Tengg-Kobligk, H.
    Pantel, J.
    Griffiths, P. D.
    Peitgen, H. O.
    Schroder, J.
    Essig, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (07) : 1454 - 1458
  • [24] Utility of MRI measurements of the medial temporal lobe for the diagnosis of Alzheimer's
    Scheltens, P
    Boscher, L
    NEUROBIOLOGY OF AGING, 2001, 22 (02) : 341 - 341
  • [25] Anatomy of D2 and D3 receptor neurons in the human medial temporal lobe
    Joyce, JN
    Gurevich, EV
    BIOLOGICAL PSYCHIATRY, 1997, 41 : A182 - A182
  • [26] 3D tracking of cellulose fibres in volume images
    Axelsson, Maria
    2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 2005 - 2008
  • [27] Evaluation of mandibular calcification on 3D volume images
    Schreiner-Tiefenbacher, Barbara
    Forster, Vivian
    Pauli, Klaudio
    Sutter, Walter
    Meier, Marius
    Roland, Henning
    Bandura, Patrick
    Turhani, Dritan
    HELIYON, 2019, 5 (05)
  • [28] Segmentation of MR images for 3D volume reconstruction
    Masero, V
    Silva, AM
    León-Rojas, JM
    Moreno, J
    METMBS'01: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MATHEMATICS AND ENGINEERING TECHNIQUES IN MEDICINE AND BIOLOGICAL SCIENCES, 2001, : 458 - 462
  • [29] Estimating 3D Fibre Orientation in Volume Images
    Axelsson, Maria
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 1762 - 1765
  • [30] Parallel volume projection in 3D medical images
    Larrazabal, G
    Escalona, P
    Montilla, G
    Torrealba, V
    Acuna, M
    Barrios, V
    SIMULATION MODELLING IN BIOENGINEERING, 1996, : 209 - 216