Reliability of medial temporal lobe volume measurements using reformatted 3D images

被引:56
|
作者
Bartzokis, G
Altshuler, LL
Greider, T
Curran, J
Keen, B
Dixon, WJ
机构
[1] W Los Angeles Vet Affairs Med Ctr, Res Serv, Los Angeles, CA 90073 USA
[2] Univ Calif Los Angeles, Dept Psychiat, Los Angeles, CA 90074 USA
[3] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90074 USA
[4] Gen Elect Med Syst, Milwaukee, WI 53188 USA
关键词
magnetic resonance imaging; methodology; temporal horn; hippocampus; amygdala;
D O I
10.1016/S0925-4927(98)00007-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The study assessed whether standardizing the angle of image display and controlling for head position in three planes affects the scan-rescan reliability of medial temporal lobe volume measures when very thin (1.5 mm) slices are used. Five volunteers were scanned two times oil consecutive days. A three-dimensional MRI sequence acquired whole brain data in 1.4 mm thick coronal slices. The data were displayed as 1.5 mm thick images and were rated both in the originally acquired coronal plane, and after reformatting to correct for head tilt and display the brain in the coronal plane perpendicular to the long axis of the left anterior hippocampus. One rater measured five brain regions (temporal lobe, anterior and posterior hippocampus, amygdala, and temporal horn) on the left and right sides of the two non-reformatted and two reformatted scans to obtain inter-scan variance. Furthermore, most scans were remeasured, to obtain 'reread' variances. All data were log-transformed in order to produce comparable variability across brain regions of different sizes. For all the regions, except the temporal horn, the non-reformatted scans showed significantly larger scan-rescan variability than the reformatted scans. A typical standard deviation for a non-reformatted pair of scans was 0.10, corresponding to 26% error, while a typical value for a reformatted pair of scans was 0.04, corresponding to 10% error. For all the regions, the reread data (intra-rater reliability) gave similar results for both reformatted and non-reformatted images with similar standard deviations (typical value for reread standard deviation was 0.020, corresponding to 5% error). The data suggest that, even when very thin slices are acquired, volume measurement accuracy of gray matter structures in the temporal lobe is considerably improved by controlling for image orientation in three planes. For these structures, the sample size needed to detect a small (5%) within-subject volume change would be halved if reformatted images were used. Image contrast is an additional important factor since the reformatted T-1 weighted images used in this study, which have suboptimal CSF/brain contrast, worsened measurement accuracy in the temporal horn. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 50 条
  • [31] Segmentation of 3D CT volume images using a single 2D atlas
    Ding, F
    Leow, WK
    Wang, SC
    COMPUTER VISION FOR BIOMEDICAL IMAGE APPLICATIONS, PROCEEDINGS, 2005, 3765 : 459 - 468
  • [32] Validation of volume measurements in esophageal pseudotumors using 3D endoluminal ultrasound
    Liu, JB
    Miller, LS
    Chung, CY
    Overton, DA
    Sheera, M
    Forsberg, F
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05): : 735 - 741
  • [33] Quantification of carotid plaque volume measurements using 3D ultrasound imaging
    Landry, A
    Spence, JD
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 751 - 762
  • [34] Volume measurements of the anal sphincter complex using 3D endoanal ultrasonography
    West, RL
    Felt-Bersma, RJF
    Hansen, BE
    Kuipers, E
    GASTROENTEROLOGY, 2004, 126 (04) : A365 - A365
  • [35] Reliability and applicability of 3D measurements of posterior teeth
    Jacob, Helder B.
    Geshay, Danielle
    Carrillo, Roberto
    Buschang, Peter H.
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2014, 3 (03) : 114 - 118
  • [36] Pavement cracking measurements using 3D laser-scan images
    Ouyang, W.
    Xu, B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (10)
  • [37] Quality control of active glass 3D displays using temporal measurements
    Boher, Pierre
    Leroux, Thierry
    Bignon, Thibault
    Blanc, Pierre
    IDW/AD '12: PROCEEDINGS OF THE INTERNATIONAL DISPLAY WORKSHOPS, PT 1, 2012, 19 : 597 - 600
  • [38] Assessing the Reliability of 3D Imaging for Wound Measurements
    Hitchman, L.
    Cai, P.
    Sethi, S.
    Stirrup, A.
    Lathan, R.
    Sidapra, M.
    Smith, G.
    Carradice, D.
    Chetter, I.
    BRITISH JOURNAL OF SURGERY, 2021, 108 : 6 - 6
  • [39] Validity and reliability of the medial temporal lobe atrophy scale in a memory clinic population
    Molinder, Anna
    Ziegelitz, Doerthe
    Maier, Stephan E.
    Eckerstrom, Carl
    BMC NEUROLOGY, 2021, 21 (01)
  • [40] Validity and reliability of the medial temporal lobe atrophy scale in a memory clinic population
    Anna Molinder
    Doerthe Ziegelitz
    Stephan E. Maier
    Carl Eckerström
    BMC Neurology, 21