Reliability of medial temporal lobe volume measurements using reformatted 3D images

被引:56
|
作者
Bartzokis, G
Altshuler, LL
Greider, T
Curran, J
Keen, B
Dixon, WJ
机构
[1] W Los Angeles Vet Affairs Med Ctr, Res Serv, Los Angeles, CA 90073 USA
[2] Univ Calif Los Angeles, Dept Psychiat, Los Angeles, CA 90074 USA
[3] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90074 USA
[4] Gen Elect Med Syst, Milwaukee, WI 53188 USA
关键词
magnetic resonance imaging; methodology; temporal horn; hippocampus; amygdala;
D O I
10.1016/S0925-4927(98)00007-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The study assessed whether standardizing the angle of image display and controlling for head position in three planes affects the scan-rescan reliability of medial temporal lobe volume measures when very thin (1.5 mm) slices are used. Five volunteers were scanned two times oil consecutive days. A three-dimensional MRI sequence acquired whole brain data in 1.4 mm thick coronal slices. The data were displayed as 1.5 mm thick images and were rated both in the originally acquired coronal plane, and after reformatting to correct for head tilt and display the brain in the coronal plane perpendicular to the long axis of the left anterior hippocampus. One rater measured five brain regions (temporal lobe, anterior and posterior hippocampus, amygdala, and temporal horn) on the left and right sides of the two non-reformatted and two reformatted scans to obtain inter-scan variance. Furthermore, most scans were remeasured, to obtain 'reread' variances. All data were log-transformed in order to produce comparable variability across brain regions of different sizes. For all the regions, except the temporal horn, the non-reformatted scans showed significantly larger scan-rescan variability than the reformatted scans. A typical standard deviation for a non-reformatted pair of scans was 0.10, corresponding to 26% error, while a typical value for a reformatted pair of scans was 0.04, corresponding to 10% error. For all the regions, the reread data (intra-rater reliability) gave similar results for both reformatted and non-reformatted images with similar standard deviations (typical value for reread standard deviation was 0.020, corresponding to 5% error). The data suggest that, even when very thin slices are acquired, volume measurement accuracy of gray matter structures in the temporal lobe is considerably improved by controlling for image orientation in three planes. For these structures, the sample size needed to detect a small (5%) within-subject volume change would be halved if reformatted images were used. Image contrast is an additional important factor since the reformatted T-1 weighted images used in this study, which have suboptimal CSF/brain contrast, worsened measurement accuracy in the temporal horn. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 50 条
  • [41] Regularizing 3D medial axis using medial scaffold transforms
    Chang, Ming-Ching
    Kimia, Benjamin B.
    2008 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-12, 2008, : 1960 - 1967
  • [42] System for the complementary visualization of 3D volume images using 2D and 3D binaurally processed sonification representations
    Rossiter, D
    Ng, WY
    VISUALIZATION '96, PROCEEDINGS, 1996, : 351 - 354
  • [43] Variability of 3D US prostate volume measurements
    Tong, S
    Downey, DB
    Fenster, A
    RADIOLOGY, 1996, 201 : 140 - 140
  • [44] Progesterone shapes medial temporal lobe volume across the human menstrual cycle
    Taylor, Caitlin M.
    Pritschet, Laura
    Olsen, Rosanna K.
    Layher, Evan
    Santander, Tyler
    Grafton, Scott T.
    Jacobs, Emily G.
    NEUROIMAGE, 2020, 220
  • [45] Automated algorithm to measure changes in medial temporal lobe volume in Alzheimer disease
    Kazemifar, Samaneh
    Drozd, John J.
    Rajakumar, Nagalingam
    Borrie, Michael J.
    Bartha, Robert
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 227 : 35 - 46
  • [46] Insulin is associated with increased medial temporal lobe volume in Alzheimer's disease
    Thomas, George P.
    Honea, Robyn
    Burns, Jeffrey M.
    NEUROLOGY, 2008, 70 (11) : A451 - A451
  • [47] Medial temporal lobe volume of nondemented elderly individuals with poor cognitive functions
    Chey, Jeanyung
    Na, Dong Gyu
    Tae, Woo Suk
    Ryoo, Jae Wook
    Hong, Seung Bong
    NEUROBIOLOGY OF AGING, 2006, 27 (09) : 1269 - 1279
  • [48] Human medial temporal lobe neurons respond preferentially to personally relevant images
    Viskontas, Indre V.
    Quiroga, Rodrigo Quian
    Fried, Itzhak
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (50) : 21329 - 21334
  • [49] Age-related medial temporal lobe volume changes in Down syndrome
    Krasuski, JS
    Alexander, GE
    Horwitz, B
    Daly, E
    Rapoport, SI
    Schapiro, MB
    BIOLOGICAL PSYCHIATRY, 1997, 41 : 52 - 52
  • [50] Reliability and measurement error of breast volume calculation using 3D surface imagery
    Fearn, Nicola Rachel
    Meybodi, Farid
    Kilbreath, Sharon
    Dylke, Elizabeth
    Llanos, Catalina
    Stuart, Kirsty
    CANCER RESEARCH, 2022, 82 (04)