Low specificity of the Murex fourth-generation HIV enzyme immunoassay in Tanzanian adolescents

被引:14
|
作者
Everett, Dean B. [1 ]
Weiss, Helen A. [1 ]
Changalucha, John [2 ]
Anemona, Alessandra [1 ]
Chirwa, Tobias [2 ]
Ross, David A. [1 ]
Watson-Jones, Deborah [1 ]
Parry, John V. [3 ]
Hayes, Richard [1 ]
Mabey, David C. [1 ]
机构
[1] Univ London London Sch Hyg & Trop Med, London WC1E 7HT, England
[2] Natl Inst Med Res, Mwanza, Tanzania
[3] Ctr Infect, Hlth Protect Agcy, London, England
基金
英国医学研究理事会;
关键词
HIV tests; Africa; specificity; false positives;
D O I
10.1111/j.1365-3156.2007.01933.x
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE To determine the specificity of the Abbott Murex HIV antigen/antibody combination enzyme immunoassay (EIA) for the diagnosis of HIV infection in Tanzania. METHODS A cross-sectional survey of 7333 Tanzanian adolescents and young adults was carried out. Sera testing positive by the Murex assay were further evaluated using a battery of other EIA which detect either antibody to HIV-1 or p24 antigen, and by PCR using pol primers. RESULTS Of the 674 sera testing positive by the Murex assay, only 53 (7.9%) were confirmed. The specificity of the Murex assay was 91.5%. CONCLUSIONS Serological tests for HIV may perform differently in different populations. New diagnostic tests should not be introduced into populations in which they have not been evaluated.
引用
收藏
页码:1323 / 1326
页数:4
相关论文
共 50 条
  • [31] Is Western blot alone sufficient to confirm a reactive result of a fourth-generation HIV screening assay?
    Dobec, Marinko
    Naegeli, Adrian
    Furrer, Kurt
    Kaeppeli, Franz
    SWISS MEDICAL WEEKLY, 2006, 136 (41-42) : 672 - 673
  • [32] Clinical evaluation of the fourth-generation immunodiagnostic reagents "Elecsys HIV Duo" for screening HIV in specimens from Korean subjects
    Won, D. J.
    Choi, D.
    Kim, H.
    CLINICA CHIMICA ACTA, 2019, 493 : S53 - S54
  • [33] Acute HIV infection detection: rapid fourth-generation test or rapid molecular point-of-care HIV test?
    Carvalho Rocha, L.
    Medina, D.
    Guerreiro, R.
    Correia, H.
    Rojas, J.
    Ferreira, F.
    Verissimo, L.
    Pinto, N.
    Brito, J.
    Mendao, L.
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2018, 21
  • [34] Evaluation of the MUREX*ICE HIV-1.0.2 capture enzyme immunoassay for early identification of HIV-1 seroreverting infants in a developing country
    Lyons, SF
    Bowers, ET
    McGillivray, GM
    Blackburn, NK
    Gray, GE
    CLINICAL AND DIAGNOSTIC VIROLOGY, 1997, 8 (01): : 1 - 8
  • [35] Field accuracy of fourth-generation rapid diagnostic tests for acute HIV-1: a systematic review
    Lewis, Joseph M.
    Macpherson, Peter
    Adams, Emily R.
    Ochodo, Eleanor
    Sands, Anita
    Taegtmeyer, Miriam
    AIDS, 2015, 29 (18) : 2465 - 2471
  • [36] Real-World Clinical Performance Evaluation of a Fourth-Generation HIV Antigen/Antibody Differentiation Test
    Krasowski, Matthew D.
    Wier, Dustin
    Smith, Susan
    Riedel, Alexander
    Lauseker-Hao, Yi
    Kelner, Michael
    Wang, Sihe
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (06): : 1417 - 1432
  • [37] HIGH SPECIFICITY OF HEPATITIS-C 2ND-GENERATION ENZYME-IMMUNOASSAY IN HIV-INFECTED PATIENTS
    FLOMENBERG, P
    BALLIET, K
    BERNSTEIN, B
    GUTIERREZ, E
    CARRIGAN, D
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1995, 9 (01): : 97 - 98
  • [38] Diagnosing acute HIV infection at point of care: a retrospective analysis of the sensitivity and specificity of a fourth-generation point-of-care test for detection of HIV core protein p24
    Fitzgerald, Naomi
    Cross, Maria
    O'Shea, Siobhan
    Fox, Julie
    SEXUALLY TRANSMITTED INFECTIONS, 2017, 93 (02) : 100 - 101
  • [39] Assessment of the Ability of a Fourth-Generation Immunoassay for Human Immunodeficiency Virus (HIV) Antibody and p24 Antigen To Detect both Acute and Recent HIV Infections in a High-Risk Setting
    Pandori, Mark W.
    Hackett, John, Jr.
    Louie, Brian
    Vallari, Ana
    Dowling, Teri
    Liska, Sally
    Klausner, Jeffrey D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (08) : 2639 - 2642
  • [40] Evaluation of a fully automated, fourth generation immunoassay for the simultaneous detection of HIV antigen and antibody
    Constantine, NT
    Saville, RD
    Sobus, M
    Cleghorn, FR
    Jack, N
    Bartholomew, C
    Edwards, J
    Blattner, WA
    AIDS, 2000, 14 : S105 - S105