Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging

被引:10
|
作者
Garcia, M. [1 ]
Gloor, M. [2 ]
Wetzel, S. G. [1 ]
Radue, E. -W. [1 ]
Scheffler, K. [2 ]
Bieri, O. [2 ]
机构
[1] Univ Basel Hosp, Inst Radiol, Dept Neuroradiol, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Med Phys, Div Radiol Phys, CH-4031 Basel, Switzerland
关键词
BSSFP; Quantitative MT; Relaxation times; Normative baseline data; MULTIPLE-SCLEROSIS; RELAXATION-TIMES; T-2; TISSUE; PARAMETERS; MRI;
D O I
10.1016/j.neuroimage.2010.04.242
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compared to standard spoiled gradient echo (SPGR)-methods, balanced steady-state free precession (bSSFP) provides quantitative magnetization transfer (qMT) images with increased resolution and high signal-to-noise ratio (SNR) in clinically feasible acquisition times. The aim of this study was to acquire 3D high-resolution qMT-data to create standardized qMT-values of many single brain structures that might serve as a baseline for the future characterization of pathologies of the brain. QMT parameters, such as the fractional pool size (F), exchange rate (kf) and relaxation times of the free pool (T1, T2) were assessed in a total of 12 white matter (WM) and 11 grey matter (GM) structures in 12 healthy volunteers with MT-sensitized bSSFP. Our results were compared with qMT-data from previous studies obtained with SPGR-methods using MT-sensitizing preparation pulses with significantly lower resolution. In general, qMT-values were in good accordance with prior studies. As expected, higher F and kf and lower relaxation times were observed in WM as compared to GM structures. However, many significant differences were observed within WM and GM regions and also between different regions of the same structure like in the internal capsule where the posterior limb showed significant higher kf than the anterior limb. Significant differences for all parameters were observed between subjects. In contrast to previous studies, bSSFP allowed assessment of even small brain structures due to its high resolution. The observed differences from previous studies can partly be explained by the reduced partial volume effects. MT-sensitized bSSFP is an ideal candidate for qMT-analysis in the clinical routine as it provides high-resolution 3D qMT-data of even small brain structures in clinically feasible acquisition times. The present qMT-data can serve as a reference for the characterization of cerebral diseases. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [21] Imaging periodic currents using alternating balanced steady-state free precession
    Buracas, Giedrius T.
    Liu, Thomas T.
    Buxton, Richard B.
    Frank, Lawrence R.
    Wong, Eric C.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 140 - 148
  • [22] Fast proton spectroscopic imaging using steady-state free precession methods
    Dreher, W
    Geppert, C
    Althaus, M
    Leibfritz, D
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) : 453 - 460
  • [23] Assessment of Magnetization Transfer Effects in Myocardial Tissue Using Balanced Steady-State Free Precession (bSSFP) Cine MRI
    Weber, Oliver M.
    Speier, Peter
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 699 - 705
  • [24] Rapid high-resolution T1 mapping using a highly accelerated radial steady-state free-precession technique
    Li, Zhitao
    Bilgin, Ali
    Johnson, Kevin
    Galons, Jean-Philippe
    Vedantham, Srinivasan
    Martin, Diego R.
    Altbach, Maria I.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (01) : 239 - 252
  • [25] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [26] Fat-suppressed steady-state free precession imaging using phase detection
    Hargreaves, BA
    Vasanawala, SS
    Nayak, KS
    Hu, BS
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 210 - 213
  • [27] Ultrahigh-Resolution Imaging of the Human Brain with Phase-Cycled Balanced Steady-State Free Precession at 7 T
    Zeineh, Michael M.
    Parekh, Mansi B.
    Zaharchuk, Greg
    Su, Jason H.
    Rosenberg, Jarrett
    Fischbein, Nancy J.
    Rutt, Brian K.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 278 - 289
  • [28] High resolution diffusion-weighted imaging in fixed human brain using diffusion-weighted steady state free precession
    McNab, Jennifer A.
    Jbabdi, Saad
    Deoni, Sean C. L.
    Douaud, Gwenaelle
    Behrens, Timothy E. J.
    Miller, Karla L.
    NEUROIMAGE, 2009, 46 (03) : 775 - 785
  • [29] Improved gray-white matter contrast using magnetization prepared fast imaging with steady-state free precession (MP-FISP) brain imaging at 0.55 T
    Schaper, Jessica
    Bauman, Grzegorz
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 162 - 173
  • [30] EVALUATION OF COMPLEX CYSTIC MASSES OF THE BRAIN - VALUE OF STEADY-STATE FREE-PRECESSION MR IMAGING
    TIEN, RD
    MACFALL, J
    HEINZ, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (05) : 1049 - 1055