Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging

被引:10
|
作者
Garcia, M. [1 ]
Gloor, M. [2 ]
Wetzel, S. G. [1 ]
Radue, E. -W. [1 ]
Scheffler, K. [2 ]
Bieri, O. [2 ]
机构
[1] Univ Basel Hosp, Inst Radiol, Dept Neuroradiol, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Med Phys, Div Radiol Phys, CH-4031 Basel, Switzerland
关键词
BSSFP; Quantitative MT; Relaxation times; Normative baseline data; MULTIPLE-SCLEROSIS; RELAXATION-TIMES; T-2; TISSUE; PARAMETERS; MRI;
D O I
10.1016/j.neuroimage.2010.04.242
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compared to standard spoiled gradient echo (SPGR)-methods, balanced steady-state free precession (bSSFP) provides quantitative magnetization transfer (qMT) images with increased resolution and high signal-to-noise ratio (SNR) in clinically feasible acquisition times. The aim of this study was to acquire 3D high-resolution qMT-data to create standardized qMT-values of many single brain structures that might serve as a baseline for the future characterization of pathologies of the brain. QMT parameters, such as the fractional pool size (F), exchange rate (kf) and relaxation times of the free pool (T1, T2) were assessed in a total of 12 white matter (WM) and 11 grey matter (GM) structures in 12 healthy volunteers with MT-sensitized bSSFP. Our results were compared with qMT-data from previous studies obtained with SPGR-methods using MT-sensitizing preparation pulses with significantly lower resolution. In general, qMT-values were in good accordance with prior studies. As expected, higher F and kf and lower relaxation times were observed in WM as compared to GM structures. However, many significant differences were observed within WM and GM regions and also between different regions of the same structure like in the internal capsule where the posterior limb showed significant higher kf than the anterior limb. Significant differences for all parameters were observed between subjects. In contrast to previous studies, bSSFP allowed assessment of even small brain structures due to its high resolution. The observed differences from previous studies can partly be explained by the reduced partial volume effects. MT-sensitized bSSFP is an ideal candidate for qMT-analysis in the clinical routine as it provides high-resolution 3D qMT-data of even small brain structures in clinically feasible acquisition times. The present qMT-data can serve as a reference for the characterization of cerebral diseases. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [31] A multicontrast imaging method using steady-state free precession with alternating RF flip angles
    Kim, Joonsoo
    Seo, Hyunseok
    So, Seohee
    Park, HyunWook
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1341 - 1351
  • [32] FAST IMAGING OF CSF FLOW MOTION PATTERNS USING STEADY-STATE FREE PRECESSION (SSFP)
    JOLESZ, FA
    PATZ, S
    HAWKES, RC
    LOPEZ, I
    INVESTIGATIVE RADIOLOGY, 1987, 22 (10) : 761 - 771
  • [33] Characterizing chronic pericarditis using steady-state free-precession cine MR imaging
    Kovanlikaya, A
    Burke, LP
    Nelson, MD
    Wood, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) : 475 - 476
  • [34] Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling
    Han, Paul Kyu
    Ye, Jong Chul
    Kim, Eung Yeop
    Choi, Seung Hong
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2016, 29 (03) : 264 - 274
  • [35] MAPPING OF CSF FLOW AT LOW FIELD USING STEADY-STATE FREE PRECESSION (SSFP) IMAGING
    PATZ, S
    HAWKES, RC
    JOLESZ, F
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S14 - S14
  • [36] Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Robert R. Edelman
    Marcos Botelho
    Amit Pursnani
    Shivraman Giri
    Ioannis Koktzoglou
    Journal of Cardiovascular Magnetic Resonance, 18
  • [37] CMR Imaging of Edema in Myocardial Infarction Using Cine Balanced Steady-State Free Precession
    Kumar, Andreas
    Beohar, Nirat
    Arumana, Jain Mangalathu
    Larose, Eric
    Li, Debiao
    Friedrich, Matthias G.
    Dharmakumar, Rohan
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (12) : 1265 - 1273
  • [38] Steady-state imaging with inhomogeneous magnetization transfer contrast using multiband radiofrequency pulses
    Malik, Shaihan J.
    Teixeira, Rui P. A. G.
    West, Daniel J.
    Wood, Tobias C.
    Hajnal, Joseph V.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 935 - 949
  • [39] High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: Parallel imaging with extended cardiac data acquisition
    Park, J
    Larson, AC
    Zhang, Q
    Simonetti, O
    Li, DB
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1100 - 1106
  • [40] 3D isotropic high-resolution diffusion-weighted MRI of the whole brain with a motion-corrected steady-state free precession sequence
    O'Halloran, R. L.
    Aksoy, M.
    Van, A. T.
    Bammer, R.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 466 - 478