Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging

被引:10
|
作者
Garcia, M. [1 ]
Gloor, M. [2 ]
Wetzel, S. G. [1 ]
Radue, E. -W. [1 ]
Scheffler, K. [2 ]
Bieri, O. [2 ]
机构
[1] Univ Basel Hosp, Inst Radiol, Dept Neuroradiol, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Med Phys, Div Radiol Phys, CH-4031 Basel, Switzerland
关键词
BSSFP; Quantitative MT; Relaxation times; Normative baseline data; MULTIPLE-SCLEROSIS; RELAXATION-TIMES; T-2; TISSUE; PARAMETERS; MRI;
D O I
10.1016/j.neuroimage.2010.04.242
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compared to standard spoiled gradient echo (SPGR)-methods, balanced steady-state free precession (bSSFP) provides quantitative magnetization transfer (qMT) images with increased resolution and high signal-to-noise ratio (SNR) in clinically feasible acquisition times. The aim of this study was to acquire 3D high-resolution qMT-data to create standardized qMT-values of many single brain structures that might serve as a baseline for the future characterization of pathologies of the brain. QMT parameters, such as the fractional pool size (F), exchange rate (kf) and relaxation times of the free pool (T1, T2) were assessed in a total of 12 white matter (WM) and 11 grey matter (GM) structures in 12 healthy volunteers with MT-sensitized bSSFP. Our results were compared with qMT-data from previous studies obtained with SPGR-methods using MT-sensitizing preparation pulses with significantly lower resolution. In general, qMT-values were in good accordance with prior studies. As expected, higher F and kf and lower relaxation times were observed in WM as compared to GM structures. However, many significant differences were observed within WM and GM regions and also between different regions of the same structure like in the internal capsule where the posterior limb showed significant higher kf than the anterior limb. Significant differences for all parameters were observed between subjects. In contrast to previous studies, bSSFP allowed assessment of even small brain structures due to its high resolution. The observed differences from previous studies can partly be explained by the reduced partial volume effects. MT-sensitized bSSFP is an ideal candidate for qMT-analysis in the clinical routine as it provides high-resolution 3D qMT-data of even small brain structures in clinically feasible acquisition times. The present qMT-data can serve as a reference for the characterization of cerebral diseases. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [41] Fast high-resolution brain imaging with balanced SSFP: Interpretation of quantitative magnetization transfer towards simple MTR
    Garcia, M.
    Gloor, M.
    Radue, E. -W.
    Stippich, Ch
    Wetzel, S. G.
    Scheffler, K.
    Bieri, O.
    NEUROIMAGE, 2012, 59 (01) : 202 - 211
  • [42] High-resolution diffusion-weighted MR imaging of the human lumbosacral plexus and its branches based on a steady-state free precession imaging technique at 3T
    Zhang, Z. W.
    Song, L. J.
    Meng, Q. F.
    Li, Z. P.
    Luo, B. N.
    Yang, Y. H.
    Pei, Z.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (06) : 1092 - 1094
  • [43] High sensitivity MR acoustic radiation force imaging using transition band balanced steady-state free precession
    Zheng, Yuan
    Marx, Michael
    Miller, G. Wilson
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1532 - 1537
  • [44] Quantitative assessment of left ventricular function: Steady-state free precession MR imaging with or without sensitivity encoding
    Kacere, RD
    Pereyra, M
    Nemeth, MA
    Muthupillai, R
    Flamm, SD
    RADIOLOGY, 2005, 235 (03) : 1031 - 1035
  • [45] High-temporal resolution (<6 ms) Cine Steady-State Free Precession (SSFP) imaging for assessing LV diastolic function
    Ramkumar Krishnamurthy
    Benjamin Cheong
    Amol Pednekar
    Raja Muthupillai
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [46] Rapid Isotropic Resolution Cartilage Assessment Using Radial Alternating Repetition Time Balanced Steady-State Free-Precession Imaging
    Al Saleh, Habib
    Hernandez, Larry
    Lee, Kenneth S.
    Rosas, Humberto G.
    Block, Walter F.
    Kijowski, Richard
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (04) : 796 - 803
  • [47] 6 Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Edelman, Robert R.
    Botelho, Marcos
    Pursnani, Amit
    Giri, Shivraman
    Koktzoglou, Ioannis
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [48] IMPROVED TISSUE CONTRAST WITH STEADY-STATE FREE PRECESSION IMAGING USING DIFFERENT RF PULSE ANGLES
    PATZ, S
    HAWKES, RC
    JOLESZ, F
    ADAMS, DF
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S27 - S27
  • [49] HIGH-RESOLUTION NEUTRON RADIOGRAPHY USING PULSED AND STEADY-STATE REACTOR SOURCES
    SHOPTAUG.JR
    WHITTEMO.WL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 73 - &
  • [50] Comparison between balanced steady-state free precession and standard spoiled gradient echo magnetization transfer ratio imaging in multiple sclerosis: methodical and clinical considerations
    Amann, Michael
    Sprenger, Till
    Naegelin, Yvonne
    Reinhardt, Julia
    Kuster, Pascal
    Hirsch, Jochen G.
    Kappos, Ludwig
    Radue, Ernst-Wilhelm
    Stippich, Christoph
    Bieri, Oliver
    NEUROIMAGE, 2015, 108 : 87 - 94