Improved gray-white matter contrast using magnetization prepared fast imaging with steady-state free precession (MP-FISP) brain imaging at 0.55 T

被引:2
|
作者
Schaper, Jessica [1 ,2 ,3 ]
Bauman, Grzegorz [1 ,2 ]
Bieri, Oliver [1 ,2 ]
机构
[1] Univ Basel, Dept Biomed Engn, Basel, Switzerland
[2] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[3] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Petersgraben 4, CH-4031 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
brain; FISP; GM; WM contrast; low-field; MPRAGE; RAGE; SEGMENTATION; OPTIMIZATION;
D O I
10.1002/mrm.29838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve the gray/white matter contrast of magnetization prepared rapid gradient echo (MP-RAGE) MRI at 0.55 T by optimizing the acquisition and sequence kernel parameters. MethodsA segmented magnetization prepared rapid gradient echo prototype sequence was implemented with (MP-RAGE*) and without (MP-FISP*) radiofrequency spoiling. Optimized parameters were derived with the assistance of an extended phase graph signal simulation as a function of the relaxation times, the flip angle, the delay times, and the effective inversion time using segmentation. The resulting protocols were compared to the MP-RAGE product sequence offered by the vendor in terms of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). A tissue segmentation reproducibility study was performed on three volunteers for the product MP-RAGE and the MP-FISP*. ResultsThe MP-RAGE simulation reproduced the parameters already used in the product MP-RAGE on the scanner. An average CNR improvement of 15% for the custom MP-RAGE* over the product MP-RAGE and additional 22% for the MP-FISP* over the MP-RAGE* were observed, which is in accordance with the simulation results. The total improvement, averaged over all volunteers and regions, was 41%. The reproducibility study did not yield a significant difference between MP-RAGE and MP-FISP*. ConclusionWe presented some easy-to-implement adjustments to the MP-RAGE sequence at 0.55 T, which can lead to an overall average improvement of 41% in CNR.
引用
收藏
页码:162 / 173
页数:12
相关论文
共 50 条
  • [1] Diffusion-prepared fast imaging with steady-state free precession (DP-FISP): A rapid diffusion MRI technique at 7 T
    Lu, Lan
    Erokwu, Bernadette
    Lee, Gregory
    Gulani, Vikas
    Griswold, Mark A.
    Dell, Katherine M.
    Flask, Chris A.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 868 - 873
  • [2] MR IMAGING OF BRAIN SURFACE USING STEADY-STATE FREE PRECESSION
    TAKANE, A
    KOIZUMI, H
    MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 344 - 348
  • [3] Fast magnetic resonance imaging in steady-state precession (true FISP) in the prenatal diagnosis of a congenital brain teratoma
    Marden, FA
    Wippold, FJ
    Perry, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 427 - 430
  • [4] IMPROVED TISSUE CONTRAST WITH STEADY-STATE FREE PRECESSION IMAGING USING DIFFERENT RF PULSE ANGLES
    PATZ, S
    HAWKES, RC
    JOLESZ, F
    ADAMS, DF
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S27 - S27
  • [5] Fast proton spectroscopic imaging using steady-state free precession methods
    Dreher, W
    Geppert, C
    Althaus, M
    Leibfritz, D
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) : 453 - 460
  • [6] FAST IMAGING OF CSF FLOW MOTION PATTERNS USING STEADY-STATE FREE PRECESSION (SSFP)
    JOLESZ, FA
    PATZ, S
    HAWKES, RC
    LOPEZ, I
    INVESTIGATIVE RADIOLOGY, 1987, 22 (10) : 761 - 771
  • [7] Measurement of Deep Gray Matter Perfusion Using a Segmented True-Fast Imaging With Steady-State Precession (True-FISP) Arterial Spin-Labeling (ASL) Method at 3T
    Grossman, Elan J.
    Zhang, Ke
    An, Jing
    Voorhees, Abram
    Inglese, Matilda
    Ge, Yulin
    Oesingmann, Niels
    Xu, Jian
    Mcgorty, Kelly A.
    Chen, Qun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) : 1425 - 1431
  • [8] Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Robert R. Edelman
    Marcos Botelho
    Amit Pursnani
    Shivraman Giri
    Ioannis Koktzoglou
    Journal of Cardiovascular Magnetic Resonance, 18
  • [9] Rapid anatomical imaging of the neonatal brain using T2-prepared 3D balanced steady-state free precession
    Park, Jinho
    Jang, MinJung
    Heier, Linda
    Limperopoulos, Catherine
    Zun, Zungho
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1456 - +
  • [10] Contrast-enhanced three-dimensional fast imaging with steady-state precession (FISP) MR angiography of supraaortic vessels: Preliminary results
    Leclerc, X
    Martinat, P
    Godefroy, O
    Lucas, C
    Giboreau, F
    Ares, GS
    Leys, D
    Pruvo, JP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (08) : 1405 - 1413