Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants

被引:10
|
作者
He, Yijian [1 ,2 ]
Jiang, Yunyun [1 ]
Fan, Yuchen [1 ]
Chen, Guangming [1 ]
Tang, Liming [1 ]
机构
[1] Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ Taizhou, Res Inst, Taizhou 31800, Peoples R China
基金
国家重点研发计划;
关键词
Absorption refrigeration; Compression refrigeration; Cascade system; Ultra-low-grade heat; Performance; PERFORMANCE ANALYSIS; ABSORPTION; ENERGY; DRIVEN; R134A;
D O I
10.1016/j.renene.2020.05.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
From solar, geothermal and waste energy, ultra-low-grade heat of 45-60 degrees C is large in scale, and is still interesting challenges in converting into useful refrigeration of 7 degrees C. In this study, a novel cascade refrigeration system was developed to utilize 45-60 degrees C heat. It is composed of a novel two-stage vapor absorption refrigeration (VAR) subsystem with LiBr/H2O working pairs and a conventional vapor compression refrigeration (VCR) subsystem. The VCR subsystem employs potential R1234yf and R1234ze(E) refrigerants. The novel VAR subsystem operates by utilizing ultra-low-grade heat of renewable energy and recycling condensing heat of the VCR subsystem. Based on thermodynamic models of the novel system, its operating mechanism was theoretically investigated and discussed. The results indicate that the novel cascade system can effectively refrigerate by utilizing 45-60 degrees C ultra-low-grade heat. Its operation is mainly determined by the novel VAR subsystem. There are optimal T-m and T-g1 to maximize its performance. T-g2 has a greater impact on the optimal T-m and little effects on the optimal T-g1. Furthermore, it implies that an available temperature span could be obviously enlarged from 90 degrees C down to 45 degrees C. And, progress of utilizing ultra-low-grade heat of renewable energy could be promoted, beneficially. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:204 / 213
页数:10
相关论文
共 50 条
  • [11] Energy and exergy analysis of an environmentally-friendly hybrid absorption/recompression refrigeration system
    Razmi, Amirreza
    Soltani, M.
    Kashkooli, Farshad M.
    Farshi, L. Garousi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 164 : 59 - 69
  • [12] Operation performance of an ultralow-temperature cascade refrigeration freezer with environmentally friendly refrigerants R290-R170
    Haihui Tan
    Lingfei Xu
    Linlin Yang
    Minkai Bai
    Zhan Liu
    [J]. Environmental Science and Pollution Research, 2023, 30 : 29790 - 29806
  • [13] Mathematical modelling and performance analysis of a novel auto-cascade refrigeration cycle for ultra-low temperature applications
    Karacayli, Ibrahim
    Altay, Lutfiye
    Hepbasli, Arif
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (02) : 229 - 245
  • [14] Operation performance of an ultralow-temperature cascade refrigeration freezer with environmentally friendly refrigerants R290-R170
    Tan, Haihui
    Xu, Lingfei
    Yang, Linlin
    Bai, Minkai
    Liu, Zhan
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (11) : 29790 - 29806
  • [15] Cascade refrigeration system with environment friendly refrigerants as R290 and ammonia
    Raibhole, V.N.
    Kamble, D.A.
    [J]. International Journal of Environmental Engineering, 2022, 11 (04): : 261 - 276
  • [16] Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system
    Ye, Wenlian
    Liu, Fazhu
    Yan, Yuqin
    Liu, Yingwen
    [J]. APPLIED THERMAL ENGINEERING, 2024, 239
  • [17] A New Environmentally-Friendly System for Extracting Cellulose from Corn Straw: The Low Temperature Laccase System
    Song, Heming
    Jia, Hongge
    Wang, Qingji
    Zhao, Xinyi
    Yang, Guoxing
    Zhang, Mingyu
    Zhou, Hailiang
    Xu, Shuangping
    Zang, Yu
    Wang, Yazhen
    Ma, Liqun
    [J]. MATERIALS, 2020, 13 (02)
  • [18] Ternary refrigerant blends for ultra-low temperature refrigeration
    Mota-Babiloni, Adrian
    Fernandez-Moreno, Adrian
    Gimenez-Prades, Pau
    Udroiu, Cosmin-Mihai
    Navarro-Esbri, Joaquin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 108 - 116
  • [19] Energy and exergy analysis of low GWP refrigerants in cascade refrigeration system
    Sun, Zhili
    Wang, Qifan
    Xie, Zhiyuan
    Liu, Shengchun
    Su, Dandan
    Cui, Qi
    [J]. ENERGY, 2019, 170 : 1170 - 1180
  • [20] Multi-mode integrated system of adsorption refrigeration using desiccant coated heat exchangers for ultra-low grade heat utilization
    Pan, Q. W.
    Xu, J.
    Ge, T. S.
    Wang, R. Z.
    [J]. ENERGY, 2022, 238