Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system

被引:17
|
作者
Ye, Wenlian [1 ,4 ]
Liu, Fazhu [2 ,3 ]
Yan, Yuqin [1 ]
Liu, Yingwen [2 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[3] Alphavita Biosci Dalian Co Ltd, Dalian 116000, Liaoning, Peoples R China
[4] Zhe Jiang AMA &HIEN Technol Co Ltd, Yueqing 325600, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Response surface methodology; Desirability approach; Ultra-low temperature; Multi-objective; LOW-GWP REFRIGERANTS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; EXERGY; R152A; CYCLE;
D O I
10.1016/j.applthermaleng.2023.122130
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, multi-objective optimization of an ultra-low temperature cascade refrigeration system is presented using response surface methodology and desirability approach. Evaporation temperature, high-temperature circuit and low-temperature circuit condensation temperature, cascade temperature difference, and superheat degrees of the compressor suction are chosen as the variables, whereas COP, total exergy destruction and exergy efficiency are adopted as the responses that simultaneously maximizing COP and exergy efficiency while minimizing the exergy destruction. The quadratic models for three responses are obtained after the analysis of variance. The interactive influences of the variables on the responses are indicated. The results present that the maximum deviations between the predicted and actual values for the COP and exergy efficiency are 0.84% and 0.96%, whereas the deviations for the exergy destruction are within +/- 2% accounting for 96% of the samples. Evaporator temperature, condenser temperature, cascade temperature difference, ect. are found to be important parameters which cause great conflicts among the objective functions. A group of optimum values for the input variables are selected and validated. The derivations between predicted modeling and simulation values for the COP, total exergy destruction, and exergy efficiency are -0.604%, 2.886%, and 0.0452%, respectively, indicating that the method is efficient to optimize the performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Research on the performance of ultra-low temperature cascade refrigeration system based on low GWP refrigerants
    Zhang, Chaoxu
    Xin, Gongming
    Yan, Gang
    Zhao, Hongxia
    Han, Jitian
    Li, Zengqun
    Ju, Chengcheng
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [2] Novel Design and Thermodynamic Analyses of Cascade Refrigeration System at Ultra-Low Temperature
    Tan, Husamettin
    Erisen, Ali
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2022, 25 (01) : 142 - 150
  • [3] Thermodynamic assessment of a triple cascade refrigeration system utilizing hydrocarbon refrigerants for ultra-low temperature applications
    Faruque, Md Walid
    Nabil, Mahdi Hafiz
    Uddin, Mohammed Raihan
    Ehsan, M. Monjurul
    Salehin, Sayedus
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 14
  • [4] Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants
    He, Yijian
    Jiang, Yunyun
    Fan, Yuchen
    Chen, Guangming
    Tang, Liming
    RENEWABLE ENERGY, 2020, 157 : 204 - 213
  • [5] Response surface methodology and desirability approach to investigate and optimize the performance of a CO2 geothermal thermosyphon
    Badache, Messaoud
    Aidoun, Zine
    GEOTHERMICS, 2023, 115
  • [6] Mathematical modelling and performance analysis of a novel auto-cascade refrigeration cycle for ultra-low temperature applications
    Karacayli, Ibrahim
    Altay, Lutfiye
    Hepbasli, Arif
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (02) : 229 - 245
  • [7] Parametric analysis and performance prediction of an ultra-low temperature cascade refrigeration freezer based on an artificial neural network
    Ye, Wenlian
    Yan, Yuqin
    Zhou, Zhongyou
    Yang, Peng
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 55
  • [8] Optimization and performance improvement of ultra-low temperature cascade refrigeration system based on the isentropic efficiency curve of single-screw compressor
    Feng, Xu
    Wu, Yuting
    Du, Yanjun
    Qi, Di
    ENERGY, 2024, 298
  • [9] Application of response surface methodology and desirability approach to investigate and optimize the jet pump in a thermoacoustic Stirling heat engine
    Yang, Peng
    Chen, Hui
    Liu, Ying-wen
    APPLIED THERMAL ENGINEERING, 2017, 127 : 1005 - 1014
  • [10] Optimization for Fire Performance of Ultra-low Density Fiberboards Using Response Surface Methodology
    Wu, Zhenzeng
    Huang, Daobang
    Wang, Wei
    Chen, Tingjie
    Lin, Ming
    Xie, Yongqun
    Niu, Min
    Wang, Xiaodong
    BIORESOURCES, 2017, 12 (02): : 3790 - 3800