Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system

被引:17
|
作者
Ye, Wenlian [1 ,4 ]
Liu, Fazhu [2 ,3 ]
Yan, Yuqin [1 ]
Liu, Yingwen [2 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[3] Alphavita Biosci Dalian Co Ltd, Dalian 116000, Liaoning, Peoples R China
[4] Zhe Jiang AMA &HIEN Technol Co Ltd, Yueqing 325600, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Response surface methodology; Desirability approach; Ultra-low temperature; Multi-objective; LOW-GWP REFRIGERANTS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; EXERGY; R152A; CYCLE;
D O I
10.1016/j.applthermaleng.2023.122130
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, multi-objective optimization of an ultra-low temperature cascade refrigeration system is presented using response surface methodology and desirability approach. Evaporation temperature, high-temperature circuit and low-temperature circuit condensation temperature, cascade temperature difference, and superheat degrees of the compressor suction are chosen as the variables, whereas COP, total exergy destruction and exergy efficiency are adopted as the responses that simultaneously maximizing COP and exergy efficiency while minimizing the exergy destruction. The quadratic models for three responses are obtained after the analysis of variance. The interactive influences of the variables on the responses are indicated. The results present that the maximum deviations between the predicted and actual values for the COP and exergy efficiency are 0.84% and 0.96%, whereas the deviations for the exergy destruction are within +/- 2% accounting for 96% of the samples. Evaporator temperature, condenser temperature, cascade temperature difference, ect. are found to be important parameters which cause great conflicts among the objective functions. A group of optimum values for the input variables are selected and validated. The derivations between predicted modeling and simulation values for the COP, total exergy destruction, and exergy efficiency are -0.604%, 2.886%, and 0.0452%, respectively, indicating that the method is efficient to optimize the performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] THEORETICAL ANALYSIS OF A CASCADE REFRIGERATION SYSTEM WITH NATURAL AND SYNTHETIC WORKING FLUID PAIRS FOR ULTRA LOW TEMPERATURE APPLICATIONS
    Yilmaz, Baris
    Mancuhan, Ebru
    Yilmaz, Deniz
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2020, 40 (01) : 141 - 153
  • [32] Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
    Zhou T.
    Hao L.
    Xu X.
    Si M.
    Zhang L.
    Energy Engineering: Journal of the Association of Energy Engineering, 2024, 121 (01): : 145 - 168
  • [33] Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications
    Martinez-Angeles, Manel
    Calleja-Anta, Daniel
    Nebot-Andres, Laura
    Llopis, Rodrigo
    RESULTS IN ENGINEERING, 2024, 24
  • [34] Thermodynamic analysis and performance optimization on an ultra-low-temperature cascade refrigeration system using refrigerants R290 and R170
    Ji, Shenrui
    Liu, Zhan
    Li, Jiafeng
    Wang, Tao
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [35] Application of response surface methodology to optimize the performance of cyclone separator using mathematical models and CFD simulations
    Brar, Lakhbir Singh
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (09) : 20426 - 20436
  • [36] COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system
    Sun, Jian
    Zhang, Mingkan
    Gehl, Anthony
    Fricke, Brian
    Nawaz, Kashif
    Gluesenkamp, Kyle
    Shen, Bo
    Munk, Jeff
    Hagerman, Joe
    Lapsa, Melissa
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 (313-325) : 313 - 325
  • [37] Performance study on a low-temperature absorption-compression cascade refrigeration system driven by low-grade heat
    Xu, Yingjie
    Chen, Guangming
    Wang, Qin
    Han, Xiaohong
    Jiang, Ning
    Deng, Shiming
    ENERGY CONVERSION AND MANAGEMENT, 2016, 119 : 379 - 388
  • [38] Performance of ejection refrigeration system operating with R-1234ze(E) driven by ultra-low grade heat source
    Gagan, Jerzy
    Smierciew, Kamil
    Butrymowicz, Dariusz
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 458 - 471
  • [39] Experimental performance analysis of a packaged R290 refrigeration unit retrofitted with R170 for ultra-low temperature freezing
    Carlos Rodriguez-Criado, Juan
    Antonio Exposito-Carrillo, Jose
    Peris Perez, Bernardo
    Dominguez-Munoz, Fernando
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 105 - 114
  • [40] Application of response surface methodology to optimize the emissions and performance of a dual fuel engine using diesel and dimethyl ether
    Kumar, Nishant
    Yadav, Vinod Singh
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2024, 43 (01)