Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources

被引:0
|
作者
Zhou T. [1 ]
Hao L. [1 ]
Xu X. [2 ,3 ]
Si M. [2 ,3 ]
Zhang L. [2 ,3 ]
机构
[1] College of Mechanical Engineering, Tianjin University of Science & Technology, Tianjin
[2] School of Energy Engineering, Tianjin Sino-German University of Applied Sciences, Tianjin
[3] Tianjin “The Belt and Road” Joint Laboratory, Tianjin Sino-German University of Applied Sciences, Tianjin
关键词
load percentage of simulated heat source; ORC; power generation; resistive load; rotary valve opening;
D O I
10.32604/ee.2023.042798
中图分类号
学科分类号
摘要
This paper discussed the experimental results of the performance of an organic Rankine cycle (ORC) system with an ultra-low temperature heat source. The low boiling point working medium R134a was adopted in the system. The simulated heat source temperature (SHST) in this work was set from 39.51°C to 48.60°C by the simulated heat source module. The influence of load percentage of simulated heat source (LPSHS) between 50% and 70%, the rotary valve opening (RVO) between 20% and 100%, the resistive load between 36 Ω and 180 Ω or the no-load of the generator, as well as the autumn and winter ambient temperature on the system performance were studied. The results showed that the stability of the system was promoted when the generator had a resistive load. The power generation (PG) and generator speed (GS) of the system in autumn were better than in winter, but the expander pressure ratio (EPR) was lower than in winter. Keep RVO unchanged, the SHST, the mass flow rate (MFR) of the working medium, GS, and the PG of the system increased with the increasing of LPSHS for different generator resistance load values. When the RVO was 60%, LPSHS was 70%, the SHST was 44.15°C and the resistive load was 72 Ω, the highest PG reached 15.11 W. Finally, a simulation formula was obtained for LPSHS, resistance load, and PG, and its correlation coefficient was between 0.9818 and 0.9901. The formula can accurately predict the PG. The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792, and the relative error was within ±5%. © 2024, Tech Science Press. All rights reserved.
引用
收藏
页码:145 / 168
页数:23
相关论文
共 50 条
  • [1] Experimental investigations on the performance of a thermo-mechanical refrigeration system utilizing ultra-low temperature waste heat sources
    Sleiti, Ahmad K.
    Al-Ammari, Wahib A.
    Al-Khawaja, Mohammed
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 71 : 591 - 607
  • [2] Performance study of ultra-low temperature district heating system based on double-loop booster heat pump control strategy
    Gong, Yuexuan
    Ma, Guoyuan
    Song, Yu
    Wang, Lei
    Nie, Junrui
    Wang, Lu
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [3] Research on the performance of ultra-low temperature cascade refrigeration system based on low GWP refrigerants
    Zhang, Chaoxu
    Xin, Gongming
    Yan, Gang
    Zhao, Hongxia
    Han, Jitian
    Li, Zengqun
    Ju, Chengcheng
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [4] ANALYSIS OF RADIAL TURBINE OF ORC POWER GENERATION SYSTEM FOR LOW TEMPERATURE HEAT SOURCES
    Bo, Zemin
    Sang, Zhenkun
    Zhang, Qianqian
    Weng, Yiwu
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2015, 2016,
  • [5] APPLICATION OF AN ADVANCED SIMULATION MODEL TO A MICRO-CHP ORC-BASED SYSTEM FOR ULTRA-LOW GRADE HEAT RECOVERY
    Ziviani, Davide
    Beyene, Asfaw
    Venturini, Mauro
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 347 - 359
  • [6] Experimental study on ultra-low temperature drilling fluid in Arctic permafrost
    Zhang, Yubin
    Qiu, Zhengsong
    Zhao, Xin
    Zhong, Hanyi
    Huang, Weian
    Mu, Jiaxing
    POLAR SCIENCE, 2021, 28
  • [7] Temperature performance of sub-1V ultra-low power current sources
    Camacho-Galeano, E. M.
    Moreira, J. Q.
    Pereira, M. D.
    Cardoso, A. J.
    Galup-Montoro, C.
    Schneider, M. C.
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 2230 - 2233
  • [8] Effects of heat source temperature on the performance of ORC power generation system with low-temperature waste heat
    Han J.-T.
    Wei X.-L.
    Ma X.-L.
    Meng X.-R.
    Wu T.
    Shi W.-Q.
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2020, 34 (01): : 53 - 61
  • [9] Experimental Performance of a Micro-ORC Energy System for Low Grade Heat Recovery
    Bianchi, M.
    Branchini, L.
    De Pascale, A.
    Orlandini, V.
    Ottaviano, S.
    Pinelli, M.
    Spina, P. R.
    Suman, A.
    4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 899 - 906
  • [10] Experimental Study of Surface Morphology of Polycarbonate Ultra-low Temperature Cooling Turning
    Bao R.
    Liu K.
    Zhang J.
    Han L.
    Li J.
    Zuo Y.
    Liu H.
    Wang Y.
    Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2024, 35 (02): : 201 - 207