Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources

被引:0
|
作者
Zhou T. [1 ]
Hao L. [1 ]
Xu X. [2 ,3 ]
Si M. [2 ,3 ]
Zhang L. [2 ,3 ]
机构
[1] College of Mechanical Engineering, Tianjin University of Science & Technology, Tianjin
[2] School of Energy Engineering, Tianjin Sino-German University of Applied Sciences, Tianjin
[3] Tianjin “The Belt and Road” Joint Laboratory, Tianjin Sino-German University of Applied Sciences, Tianjin
关键词
load percentage of simulated heat source; ORC; power generation; resistive load; rotary valve opening;
D O I
10.32604/ee.2023.042798
中图分类号
学科分类号
摘要
This paper discussed the experimental results of the performance of an organic Rankine cycle (ORC) system with an ultra-low temperature heat source. The low boiling point working medium R134a was adopted in the system. The simulated heat source temperature (SHST) in this work was set from 39.51°C to 48.60°C by the simulated heat source module. The influence of load percentage of simulated heat source (LPSHS) between 50% and 70%, the rotary valve opening (RVO) between 20% and 100%, the resistive load between 36 Ω and 180 Ω or the no-load of the generator, as well as the autumn and winter ambient temperature on the system performance were studied. The results showed that the stability of the system was promoted when the generator had a resistive load. The power generation (PG) and generator speed (GS) of the system in autumn were better than in winter, but the expander pressure ratio (EPR) was lower than in winter. Keep RVO unchanged, the SHST, the mass flow rate (MFR) of the working medium, GS, and the PG of the system increased with the increasing of LPSHS for different generator resistance load values. When the RVO was 60%, LPSHS was 70%, the SHST was 44.15°C and the resistive load was 72 Ω, the highest PG reached 15.11 W. Finally, a simulation formula was obtained for LPSHS, resistance load, and PG, and its correlation coefficient was between 0.9818 and 0.9901. The formula can accurately predict the PG. The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792, and the relative error was within ±5%. © 2024, Tech Science Press. All rights reserved.
引用
收藏
页码:145 / 168
页数:23
相关论文
共 50 条
  • [21] Computational and Experimental Study of an Ultra-Low Head turbine
    Parajuli, Pradeep
    Koirala, Pratik
    Pokharel, Nischal
    Neopane, Hari Prasad
    Chitrakar, Sailesh
    Maskey, Ramesh Kumar
    2016 4TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT IN THE IN RENEWABLE ENERGY TECHNOLOGY (ICDRET), 2016,
  • [22] Experimental study on performance characteristics of a-70 ° C ultra-low temperature medical freezer with mixed hydrocarbon refrigerant
    Liu, Jiarui
    Yu, Jianlin
    Yan, Gang
    ENERGY, 2024, 307
  • [23] Reinforced Concrete Beam Stress Performance at Ultra-low Temperature
    Liu, Shuang
    Lv, Chao
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING 2011, 2011, 24 : 370 - 374
  • [24] Experimental study on hydraulic performance optimization of ultra-low specific speed centrifugal pump
    Wang, Jiaqiong
    Dang, Jianing
    Yang, Tao
    Zhang, Ruijie
    PHYSICS OF FLUIDS, 2024, 36 (08)
  • [25] Heat transfer at dielectric - metallic interfaces in the ultra-low temperature range
    Liberadzka, J.
    Golm, J.
    Koettig, T.
    Bremer, J.
    ter Brake, H. J. M.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [26] Design of Ultra-Low Temperature Online Monitoring System Based on Data Fusion Technology
    Meilian Zhao
    Peixue Liu
    Aixia Cao
    Zhiqiang Liu
    Wireless Personal Communications, 2018, 103 : 481 - 489
  • [27] Design of Ultra-Low Temperature Online Monitoring System Based on Data Fusion Technology
    Zhao, Meilian
    Liu, Peixue
    Cao, Aixia
    Liu, Zhiqiang
    WIRELESS PERSONAL COMMUNICATIONS, 2018, 103 (01) : 481 - 489
  • [28] Experimental study on mechanical behavior of reinforced concrete beams before cracking at ultra-low temperature
    Li Y.
    Yang D.
    Huang D.
    Yang, Dongwei (452511392@qq.com), 1600, Science Press (42): : 110 - 116
  • [29] Energy analysis of an ultra-low temperature district heating and cooling system with coaxial borehole heat exchangers
    Quirosa, Gonzalo
    Torres, Miguel
    Becerra, Jose A.
    Jimenez-Espadafor, Francisco J.
    Chacartegui, Ricardo
    ENERGY, 2023, 278
  • [30] Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants
    He, Yijian
    Jiang, Yunyun
    Fan, Yuchen
    Chen, Guangming
    Tang, Liming
    RENEWABLE ENERGY, 2020, 157 : 204 - 213