Experimental investigations on the performance of a thermo-mechanical refrigeration system utilizing ultra-low temperature waste heat sources

被引:2
|
作者
Sleiti, Ahmad K. [1 ]
Al-Ammari, Wahib A. [1 ]
Al-Khawaja, Mohammed [1 ]
机构
[1] Qatar Univ, Coll Engn, Dept Mech & Ind Engn, Doha, Qatar
关键词
Ultra-low temperature; Waste heat; Thermo-mechanical refriger-ation; Pneumatic pump; R134a; R407C; ORGANIC RANKINE-CYCLE; LOW-GRADE HEAT; OPTIMIZATION; DESIGN;
D O I
10.1016/j.aej.2023.03.083
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Experimental studies that investigate the utilization of ultra-low temperature (between 48 degrees C and 120 degrees C) waste heat, which forms 25 % of the global unrecovered waste heat, to drive thermal cooling systems are rare. Thus, this study fills a significant gap in the literature by (i) exper-imentally evaluating the performance of a new full-scale thermo-mechanical refrigeration (TMR) system at ultra-low temperatures ranging from 50 degrees C to 85 degrees C, (ii) characterizing its operation with different commercial refrigerants, and (iii) identifying optimal operating conditions and working fluids for the investigated TMR system. An organic Rankine cycle (ORC), vapor compression cycle (VCC), and expander-compressor unit (ECU) make up the TMR system. To ensure its efficient operation, flexibility, and reliability, a full-scale ECU-based TMR system with a design capacity of 1 kW at a heat source temperature of 85 degrees C is built and put through a series of tests. Further-more, the TMR system is tested with different commercial refrigerants (R134a, R410A, R407C) over a wide range of operating conditions of the power loop. The results reveal that the ECU -based TMR system can work with ultra-low temperatures of 65 degrees C with an energy efficiency of 5.92 % and COP of 2.36, for the ORC and VCC, respectively. At a heat source temperature of 85 degrees C, a condenser water temperature of 15 degrees C, and an evaporator water temperature of 33 degrees C, the energy efficiency of the ORC and COP of the VCC are increased to 9.85 % and 3.99, respec-tively. For the cooling quality, the TMR system shows a minimum evaporator temperature of -10 degrees C using R134a in both the power and cooling loop, which is improved to lower than -20 degrees C by using R407C in the cooling loop. The results presented herein will be beneficial to the development, design, and optimization of refrigeration and power systems that utilize low -temperature waste heat.(c) 2023 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/ 4.0/).
引用
收藏
页码:591 / 607
页数:17
相关论文
共 50 条
  • [1] HEAT TRANSFER ANALYSIS OF REGENERATIVE THERMO-MECHANICAL REFRIGERATION SYSTEM
    Sleiti, Ahmad K.
    Al-Khawaja, Mohammed
    [J]. PROCEEDINGS OF THE ASME 2020 HEAT TRANSFER SUMMER CONFERENCE (HT2020), 2020,
  • [2] Thermodynamic assessment of a triple cascade refrigeration system utilizing hydrocarbon refrigerants for ultra-low temperature applications
    Faruque, Md Walid
    Nabil, Mahdi Hafiz
    Uddin, Mohammed Raihan
    Ehsan, M. Monjurul
    Salehin, Sayedus
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2022, 14
  • [3] Experimental investigation on the performance of a novel thermo-mechanical refrigeration system driven by an expander-compressor unit
    Sleiti, Ahmad K.
    Al-Ammari, Wahib A.
    Al-Khawaja, Mohammed
    Saker, Ahmad T.
    [J]. APPLIED THERMAL ENGINEERING, 2022, 212
  • [4] Review of innovative approaches of thermo-mechanical refrigeration systems using low grade heat
    Sleiti, Ahmad K.
    Al-Ammari, Wahib A.
    Al-Khawaja, Mohammed
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (13) : 9808 - 9838
  • [5] Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants
    He, Yijian
    Jiang, Yunyun
    Fan, Yuchen
    Chen, Guangming
    Tang, Liming
    [J]. RENEWABLE ENERGY, 2020, 157 : 204 - 213
  • [6] Novel Design and Thermodynamic Analyses of Cascade Refrigeration System at Ultra-Low Temperature
    Tan, Husamettin
    Erisen, Ali
    [J]. INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2022, 25 (01) : 142 - 150
  • [7] Thermo-Mechanical Investigations of Packed Beds for High Temperature Heat Storage: Continuum Modeling
    Knoedler, Philipp
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (12):
  • [8] Thermal Investigations into an Organic Rankine Cycle (ORC) System Utilizing Low Grade Waste Heat Sources
    Zhou, Xinlei
    Cui, Ping
    Wang, Xiaoying
    He, Lixia
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 4142 - 4148
  • [9] EVALUATION ON THERMO-MECHANICAL INTEGRITY OF THERMOELECTRIC MODULE FOR HEAT RECOVERY AT LOW TEMPERATURE
    Nakatani, Yujiro
    Shindo, Takahiko
    Wakamatsu, Kengo
    Hino, Takehisa
    Ohishi, Takashi
    Matsumuro, Haruo
    Itoh, Yoshiyasu
    [J]. DEVELOPMENTS IN STRATEGIC MATERIALS, 2009, 29 (10): : 69 - +
  • [10] A combined thermo-mechanical refrigeration system with isobaric expander-compressor unit powered by low grade heat – Design and analysis
    Sleiti, Ahmad K.
    Al-Khawaja, Mohammed
    Al-Ammari, Wahib A.
    [J]. International Journal of Refrigeration, 2020, 120 : 39 - 49