Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system

被引:17
|
作者
Ye, Wenlian [1 ,4 ]
Liu, Fazhu [2 ,3 ]
Yan, Yuqin [1 ]
Liu, Yingwen [2 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[3] Alphavita Biosci Dalian Co Ltd, Dalian 116000, Liaoning, Peoples R China
[4] Zhe Jiang AMA &HIEN Technol Co Ltd, Yueqing 325600, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Response surface methodology; Desirability approach; Ultra-low temperature; Multi-objective; LOW-GWP REFRIGERANTS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; EXERGY; R152A; CYCLE;
D O I
10.1016/j.applthermaleng.2023.122130
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, multi-objective optimization of an ultra-low temperature cascade refrigeration system is presented using response surface methodology and desirability approach. Evaporation temperature, high-temperature circuit and low-temperature circuit condensation temperature, cascade temperature difference, and superheat degrees of the compressor suction are chosen as the variables, whereas COP, total exergy destruction and exergy efficiency are adopted as the responses that simultaneously maximizing COP and exergy efficiency while minimizing the exergy destruction. The quadratic models for three responses are obtained after the analysis of variance. The interactive influences of the variables on the responses are indicated. The results present that the maximum deviations between the predicted and actual values for the COP and exergy efficiency are 0.84% and 0.96%, whereas the deviations for the exergy destruction are within +/- 2% accounting for 96% of the samples. Evaporator temperature, condenser temperature, cascade temperature difference, ect. are found to be important parameters which cause great conflicts among the objective functions. A group of optimum values for the input variables are selected and validated. The derivations between predicted modeling and simulation values for the COP, total exergy destruction, and exergy efficiency are -0.604%, 2.886%, and 0.0452%, respectively, indicating that the method is efficient to optimize the performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Innovative system designs to optimize performance of ultra-low pressure reverse osmosis membranes
    Nemeth, JE
    DESALINATION, 1998, 118 (1-3) : 63 - 71
  • [23] Ultra-low Temperature Refrigeration System of CO2 using Cyclone Separator/Evaporator
    Yamaguchi, H.
    Ishikawa, Y.
    Yamasaki, H.
    Kamimura, T.
    Hattori, K.
    Neksa, P.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1758 - 1763
  • [24] Energy, exergy, environmental and exergoeconomic (4E) analysis of an ultra-low temperature cascade refrigeration system with environmental-friendly refrigerants
    Ji, Shenrui
    Liu, Zhan
    Pan, Hao
    Li, Xiaozhao
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [25] Energy, exergy, environmental and exergoeconomic (4E) analysis of an ultra-low temperature cascade refrigeration system with environmental-friendly refrigerants
    Ji, Shenrui
    Liu, Zhan
    Pan, Hao
    Li, Xiaozhao
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [26] Performance Evaluation of Modified Low-Temperature Cascade (MLTC) Type Refrigeration System
    Siddiqui, Mohd Waseem
    Das, Nishith Kumar
    Sahoo, R. K.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (03)
  • [27] An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
    Barroca, Pierre
    Hafner, Armin
    Verlaat, Bart
    Petagna, Paolo
    Hulek, Wojciech
    Zwalinski, Lukasz
    Hanf, Pierre
    Battistin, Michele
    Davoine, Loic
    Teixeira, Daniella
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [28] Application of response surface methodology to optimize nitrate removal at low temperature by aerobic denitrificator Pseudomonas strain An-1
    Ren, He-Jun
    Su, Yu
    Wang, Cong
    Hou, Zhi-Min
    Zhou, Ye
    Zhou, Rui
    WATER AND ENVIRONMENT JOURNAL, 2018, 32 (02) : 235 - 241
  • [29] Application of response surface methodology to optimize and investigate the effects of operating conditions on the performance of DMFC
    Taymaz, Imdat
    Akgun, Fehmi
    Benli, Merthan
    ENERGY, 2011, 36 (02) : 1155 - 1160
  • [30] Application of response surface methodology to optimize decolourization of dyes by the laccase-mediator system
    Daassi, Dalel
    Frikha, Fakher
    Zouari-Mechichi, Hela
    Belbahri, Lassaad
    Woodward, Steve
    Mechichi, Tahar
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2012, 108 : 84 - 91