Evaluation of a physiologic pulsatile pump system for neonate-infant cardiopulmonary bypass support

被引:0
|
作者
Ündar, A
Masai, T
Inman, R
Beyer, EA
Mueller, MA
McGarry, MC
Frazier, OH
Fraser, CD
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Congenital Heart Surg Serv, Houston, TX 77030 USA
[2] Baylor Coll Med, Texas Heart Inst, Cullen Cardiovasc Surg Res Labs, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Surg, Sect Congenital Heart Surg, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternate physiologic pulsatile pump (PPP) system was designed and evaluated to produce sufficient pulsatility during neonate-infant open heart surgery. This hydraulically driven pump system has a unique "dual" pumping chamber mechanism. The first chamber is placed between the venous reservoir and oxygenator and the second chamber between the oxygenator and patient. Each chamber has two unidirectional tricuspid valves. Stroke volume (0.2-10 ml), upstroke rise time (10-350 msec), and pump rate (2-250 beats per minute [bpm]) can be adjusted independently to produce adequate pulsatility. This system has been tested in 3-kg piglets (n = 6), with a pump flow of 150 ml/kg/min, a pump rate of 150 bpm, and a pump ejection time of 110 msec. After initiation of cardiopulmonary bypass (CPB), all animals were subjected to 25 minutes of hypothermia to reduce the rectal temperatures to 18 degrees C, 60 minutes of deep hypothermic circulatory arrest (DHCA), then 10 minutes of cold perfusion with a full pump flow, and 40 minutes of rewarming. During CPB, mean arterial pressures were kept at less than 50 mm Hg. Mean extracorporeal circuit pressure (ECCP), the pressure drop of a 10 French aortic cannula, and the pulse pressure were 67 +/- 9, 21 +/- 6, and 16 +/- 2 mm Hg, respectively. All values are represented as mean +/- SD. No regurgitation or abnormal hemolysis has been detected during these experiments. The oxygenator had no damping effect on the quality of the pulsatility because of the dual chamber pumping mechanism. The ECCP was also significantly lower than any other known pulsatile system. We conclude that this system, with a 10 French aortic cannula and arterial filter, produces adequate pulsatility in 3 kg piglets.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [31] A Hemodynamic evaluation of the medos deltastream DP1 rotary pump and Jostra HL-20 roller pump under pulsatile and nonpulsatile perfusion in an infant cardiopulmonary bypass model -: A pilot study
    Rider, Alan R.
    Griffith, Kimberly
    Ressler, Noel
    Kunselman, Allen R.
    Wang, Shigang
    Undar, Akif
    ASAIO JOURNAL, 2008, 54 (05) : 529 - 533
  • [32] In Vivo Evaluation of Centrifugal Blood Pump for Cardiopulmonary Bypass-Spiral Pump
    da Silva, Cibele
    da Silva, Bruno Utiyama
    Leme, Juliana
    Uebelhart, Beatriz
    Dinkhuysen, Jarbas
    Biscegli, Jose F.
    Andrade, Aron
    Zavaglia, Cecilia
    ARTIFICIAL ORGANS, 2013, 37 (11) : 954 - 957
  • [33] CLINICAL EFFECTS OF PULSATILE CARDIOPULMONARY BYPASS (CPB) USING A MODIFIED DEBAKEY ROLLER-PUMP
    NOON, GP
    HARRELL, JE
    YAWN, D
    FELDMAN, L
    FOX, F
    WEISS, P
    MUNOZ, A
    KENT, P
    DEBAKEY, ME
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 138 - 142
  • [34] NEW METHOD OF PRODUCING PULSATILE FLOW DURING CARDIOPULMONARY BYPASS USING A STANDARD ROLLER PUMP
    CIARDULLO, R
    SCHAFF, HV
    FLAHERTY, JT
    GOTT, VL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 72 (04): : 585 - 587
  • [35] Stockert roller pump generated pulsatile flow: cerebral metabolic changes in adult cardiopulmonary bypass
    Uendar, Akif
    Calhoon, John H.
    PERFUSION-UK, 1998, 13 (03): : 215 - 216
  • [36] Platelet dysfunction in cardiopulmonary bypass:: An experimental comparative study between a centrifugal and a new pulsatile pump
    Herreros, J
    Berjano, EJ
    Más, P
    Padrós, C
    Sales-Nebot, L
    Vlaanderen, W
    Díaz, P
    Páramo, JA
    Rábago, G
    Mercé, S
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2003, 26 (12): : 1086 - 1094
  • [37] Regional blood flow during pulsatile cardiopulmonary bypass and after circulatory arrest in an infant model
    Lodge, AJ
    Undar, A
    Daggett, CW
    Runge, TM
    Calhoon, JH
    Ungerleider, RM
    ANNALS OF THORACIC SURGERY, 1997, 63 (05): : 1243 - 1250
  • [38] Development of an affordable diaphragmatic pump for cardiopulmonary bypass: An in vivo evaluation
    Xiao, XJ
    Fan, RX
    Cheng, AH
    Gao, WM
    Ding, YQ
    Zhang, XH
    Ye, CX
    Luo, ZX
    ARTIFICIAL ORGANS, 2000, 24 (11) : 915 - 918
  • [39] Balloon pump-induced pulsatile perfusion during cardiopulmonary bypass does not improve brain oxygenation
    Kawahara, F
    Kadoi, Y
    Saito, S
    Yoshikawa, D
    Goto, F
    Fujita, N
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (02): : 361 - 366
  • [40] Regional blood flow during pulsatile cardiopulmonary bypass and after circulatory arrest in an infant model - Discussion
    Hill, RC
    Lodge, AJ
    ANNALS OF THORACIC SURGERY, 1997, 63 (05): : 1250 - 1250