Platelet dysfunction in cardiopulmonary bypass:: An experimental comparative study between a centrifugal and a new pulsatile pump

被引:11
|
作者
Herreros, J
Berjano, EJ
Más, P
Padrós, C
Sales-Nebot, L
Vlaanderen, W
Díaz, P
Páramo, JA
Rábago, G
Mercé, S
机构
[1] Univ Politecn Valencia, Dept Elect Engn, E-46071 Valencia, Spain
[2] Univ Navarra, Clin Univ, Dept Cardiovasc Surg, E-31080 Pamplona, Spain
[3] MERCE V Electromed SL, Dept Res & Dev, Valencia, Spain
[4] Univ Navarra, Clin Univ, Dept Hematol, E-31080 Pamplona, Spain
来源
关键词
cardiopulmonary bypass; extracorporeal circulation; perfusion; platelet count; platelet function analysis; pulsatile flow;
D O I
10.1177/039139880302601206
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this investigation was to study the effect of a new pulsatile pump for extracorporeal circulation (ECC) on platelet count and platelet function with respect to a Biomedicus centrifugal pump. Thirteen pigs, 8 in the pulsatile group (PG) and 5 in the centrifugal group (CG), underwent a partial extracorporeal circulation lasting 3h. The animals were sacrificed 3h post-ECC. The platelet study was both quantitative (platelet count) and qualitative (platelet function analysis) by assessing the closure time (CT) with a PFA-100 system. The decrease in platelet number from basal to 3h post ECC was only significant in CG (p = 0.009). The platelet function was impaired in both groups, but the value of CT with col/ADP increased significantly only in CG (p < 0.00 1). The increase of CT with col/EPI was greater in CG (p = 0.07) than in PG (p = 0.2). The results indicated that the new pulsatile pump preserves platelets quantitatively and qualitatively well compared to a Biomedicus pump.
引用
收藏
页码:1086 / 1094
页数:9
相关论文
共 50 条
  • [1] Injury in organs after cardiopulmonary bypass:: A comparative experimental morphological study between a centrifugal and a new pulsatile pump
    Herreros, J
    Berjano, EJ
    Sola, J
    Vlaanderen, W
    Sales-Nebot, L
    Más, P
    Padrós, C
    Díaz, P
    Rábago, G
    Mercé, S
    [J]. ARTIFICIAL ORGANS, 2004, 28 (08) : 738 - 742
  • [2] Experimental comparative study between a centrifugal and a new pulsatile pump: platelet assessment and histological study after extracorporeal circulation
    Herreros, Jesus
    Berjano, Enrique J.
    Sola, Josu
    Vlaanderen, Wouter
    Sales-Nebot, Laura
    Mas, Pedro
    Padros, Clemente
    Diaz, Pedro
    Paramo, Jose A.
    Rabago, Gregorio
    Merce, Salvador
    [J]. CIRUGIA CARDIOVASCULAR, 2006, 13 (03): : 151 - 161
  • [3] A new blood pump for cardiopulmonary bypass: The HiFlow centrifugal pump
    Gobel, C
    Eilers, R
    Reul, H
    Schwindke, P
    Jorger, M
    Rau, G
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 841 - 845
  • [4] PULSATILE FLOW DURING CARDIOPULMONARY BYPASS - EVALUATION OF A NEW PULSATILE PUMP
    WAABEN, J
    ANDERSEN, K
    HUSUM, B
    [J]. SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 19 (02): : 149 - 153
  • [5] METABOLIC COMPARISON OF A NEW PULSATILE PUMP AND A ROLLER PUMP FOR CARDIOPULMONARY BYPASS
    TRINKLE, JK
    HELTON, NE
    WOOD, RE
    BRYANT, LR
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04): : 562 - &
  • [6] In vitro comparison of blood pump induced platelet microaggregates between a centrifugal and roller pump during cardiopulmonary bypass
    Linneweber, J
    Chow, T
    Kawamura, M
    Moake, JL
    Nosè, Y
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (06): : 549 - 555
  • [7] A COMPACT CENTRIFUGAL PUMP FOR CARDIOPULMONARY BYPASS
    SASAKI, T
    JIKUYA, T
    AIZAWA, T
    SHIONO, M
    SAKUMA, I
    TAKATANI, S
    GLUECK, J
    NOON, GP
    NOSE, Y
    DEBAKEY, ME
    [J]. ARTIFICIAL ORGANS, 1992, 16 (06) : 592 - 598
  • [8] CARDIOPULMONARY BYPASS USING CENTRIFUGAL PUMP
    BERKI, T
    GURBUZ, A
    ISIK, O
    AKKAYA, H
    BAYEZID, O
    YAKUT, C
    [J]. VASCULAR SURGERY, 1992, 26 (02): : 123 - 134
  • [9] PULSATILE PUMP CONTROL IN CARDIOPULMONARY BYPASS SYSTEM
    TUCHIYA, K
    UMEZU, M
    FUJIMOTO, T
    TOMINO, T
    [J]. ARTIFICIAL ORGANS, 1980, 4 (02) : 150 - 150
  • [10] Clinical trial of a new pulsatile pump for cardiopulmonary bypass: preliminary findings
    Martinez Leon, J.
    Herreros, J.
    Garcia, J.
    Vila Nunez, J. E.
    Fontana, J.
    Berjano, E. J.
    Merce, S.
    [J]. BRITISH JOURNAL OF SURGERY, 2010, 97 : S66 - S67