Evaluation of a physiologic pulsatile pump system for neonate-infant cardiopulmonary bypass support

被引:0
|
作者
Ündar, A
Masai, T
Inman, R
Beyer, EA
Mueller, MA
McGarry, MC
Frazier, OH
Fraser, CD
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Congenital Heart Surg Serv, Houston, TX 77030 USA
[2] Baylor Coll Med, Texas Heart Inst, Cullen Cardiovasc Surg Res Labs, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Surg, Sect Congenital Heart Surg, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternate physiologic pulsatile pump (PPP) system was designed and evaluated to produce sufficient pulsatility during neonate-infant open heart surgery. This hydraulically driven pump system has a unique "dual" pumping chamber mechanism. The first chamber is placed between the venous reservoir and oxygenator and the second chamber between the oxygenator and patient. Each chamber has two unidirectional tricuspid valves. Stroke volume (0.2-10 ml), upstroke rise time (10-350 msec), and pump rate (2-250 beats per minute [bpm]) can be adjusted independently to produce adequate pulsatility. This system has been tested in 3-kg piglets (n = 6), with a pump flow of 150 ml/kg/min, a pump rate of 150 bpm, and a pump ejection time of 110 msec. After initiation of cardiopulmonary bypass (CPB), all animals were subjected to 25 minutes of hypothermia to reduce the rectal temperatures to 18 degrees C, 60 minutes of deep hypothermic circulatory arrest (DHCA), then 10 minutes of cold perfusion with a full pump flow, and 40 minutes of rewarming. During CPB, mean arterial pressures were kept at less than 50 mm Hg. Mean extracorporeal circuit pressure (ECCP), the pressure drop of a 10 French aortic cannula, and the pulse pressure were 67 +/- 9, 21 +/- 6, and 16 +/- 2 mm Hg, respectively. All values are represented as mean +/- SD. No regurgitation or abnormal hemolysis has been detected during these experiments. The oxygenator had no damping effect on the quality of the pulsatility because of the dual chamber pumping mechanism. The ECCP was also significantly lower than any other known pulsatile system. We conclude that this system, with a 10 French aortic cannula and arterial filter, produces adequate pulsatility in 3 kg piglets.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [21] Clinical trial of a new pulsatile pump for cardiopulmonary bypass: preliminary findings
    Martinez Leon, J.
    Herreros, J.
    Garcia, J.
    Vila Nunez, J. E.
    Fontana, J.
    Berjano, E. J.
    Merce, S.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : S66 - S67
  • [22] A new pulsatile blood pump for adult cardiopulmonary bypass: Design criteria and preliminary fluid dynamic evaluation
    Inzoli, F
    DiMartino, E
    Dubini, G
    Redaelli, A
    Fumero, R
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (06): : 359 - 366
  • [23] An evaluation of renal functions in pulsatile and non-pulsatile cardiopulmonary bypass in the elderly
    Hokenek, Faruk
    Gursoy, Mete
    Bakuy, Vedat
    Kavala, Ali Aycan
    Demir, Tarik
    Gulcan, Fusun
    Kinoglu, Barbaros
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 21 (03): : 610 - 615
  • [24] Comparison of Pumps and Oxygenators With Pulsatile and Nonpulsatile Modes in an Infant Cardiopulmonary Bypass Model
    Haines, Nikkole M.
    Wang, Shigang
    Kunselman, Allen
    Myers, John L.
    Undar, Akif
    ARTIFICIAL ORGANS, 2009, 33 (11) : 993 - 1001
  • [25] Experimental study of the salvapump system for pulsatile perfusion in cardiopulmonary bypass
    Herreros, J.
    Ubilla, M.
    Berjano, E. J.
    Garcia, J.
    Vila Nunez, J. E.
    Paramo, J. A.
    Sola, J.
    Merce, S.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : S59 - S59
  • [26] PERCUTANEOUS CARDIOPULMONARY BYPASS WITH A SYNCHRONOUS PULSATILE PUMP COMBINES EFFECTIVE UNLOADING WITH EASE OF APPLICATION
    AXELROD, HI
    GALLOWAY, AC
    MURPHY, MS
    LASCHINGER, JC
    BAUMANN, FG
    GROSSI, EA
    GLASSMAN, E
    SPENCER, FC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 93 (03): : 358 - 365
  • [27] Comparison of the effects of pulsatile cardiopulmonary bypass, non-pulsatile cardiopulmonary bypass and off-pump coronary artery bypass grafting on the inflammatory response and S-100beta protein
    Bayram, H.
    Erer, D.
    Iriz, E.
    Zor, M. H.
    Gulbahar, O.
    Ozdogan, M. E.
    PERFUSION-UK, 2012, 27 (01): : 56 - 64
  • [28] Effects of pulsatile cardiopulmonary bypass on cerebral recovery from circulatory arrest in an infant model
    Lodge, AJ
    Undar, A
    Daggett, CW
    Srinivasan, M
    Runge, TM
    Calhoon, JH
    Ungerleider, RM
    CIRCULATION, 1997, 96 (08) : 721 - 721
  • [29] A Nonocclusive, Inexpensive Pediatric Pulsatile Roller Pump for Cardiopulmonary Bypass, Extracorporeal Life Support, and Left/Right Ventricular Assist Systems
    Wang, Shigang
    Durandy, Yves
    Kunselman, Allen R.
    Uendar, Akif
    ARTIFICIAL ORGANS, 2013, 37 (01) : 48 - 56
  • [30] Affinity pump system:: a new peristaltic blood pump for cardiopulmonary bypass
    Jaggy, C
    Lachat, M
    Leskosek, B
    Zünd, G
    Turina, M
    PERFUSION-UK, 2000, 15 (01): : 77 - 83