Coincidence detection FDG PET in the management of oncological patients: attenuation correction versus non-attenuation correction

被引:6
|
作者
Chan, WL [1 ]
Freund, J [1 ]
Pocock, NA [1 ]
Szeto, E [1 ]
Chan, F [1 ]
Sorensen, BJ [1 ]
McBride, B [1 ]
机构
[1] St Vincents Hosp, Dept Nucl Med, Sydney, NSW, Australia
关键词
fluorodeoxyglucose; Co-PET; attenuation correction; neoplasm;
D O I
10.1097/00006231-200111000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine if attenuation correction (AC) in a dual-head, coincidence, positron emission tomography imaging system (Co-PET) improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation corrected (NAC) images. Thirty patients with known or suspected malignant neoplasms underwent fluorodeoxyglucose (FDG) Co-PET, which was correlated with histopathology, computed tomography (CT) and other conventional imaging modalities and clinical follow-up. The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality in the AC versus NAC Co-PET images. AC Co-PET was statistically superior to NAC Co-PET in relation to lesion detection (P < 0.01) and tumour staging (P < 0.01). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET altered tumour staging in five additional patients (16%) compared to NAC Co-PET. Management was altered in two of these five patients. ((C) 2001 Lippincott Williams & Wilkins).
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [41] Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET
    Buvat, Irène
    Freedman, Nanette M. T.
    Dilsizian, Vasken
    Bacharach, Stephen L.
    Journal of Computer Assisted Tomography, 20 (05): : 848 - 854
  • [42] PET attenuation correction using mean attenuation coefficients: A simulation study
    Madsen, MT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2172 - 2176
  • [43] Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction
    Sekine, Tetsuro
    ter Voert, Edwin E. G. W.
    Warnock, Geoffrey
    Buck, Alfred
    Huellner, Martin
    Veit-Haibach, Patrick
    Delso, Gaspar
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1927 - 1932
  • [44] Attenuation correction without transmission scanning for FDG lung studies on a coincidence camera system.
    Lalush, DS
    Tsui, BMW
    Tocharoenchai, C
    Zhao, XD
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 114P - 114P
  • [45] Impact of attenuation correction on the accuracy of FDG-PET in patients with abdominal tumors:: An ROC analysis.
    Hustinx, R
    Dolin, RJ
    Bénard, F
    Bhatnagar, A
    Smith, RJ
    Jang, S
    Alavi, A
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 139P - 140P
  • [46] Effect of sinus attenuation in MR-based attenuation correction in 18F-FDG brain PET/MR
    Teuho, J.
    Tuisku, J.
    Linden, J.
    Teras, M.
    EMBEC & NBC 2017, 2018, 65 : 266 - 269
  • [47] IMPLEMENTATION AND EVALUATION OF A CALCULATED ATTENUATION CORRECTION FOR PET
    SIEGEL, S
    DAHLBOM, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 1117 - 1121
  • [48] Attenuation correction and iterative reconstruction for PET.
    Yao, R
    Johnson, CA
    Riddell, C
    Bacharach, SL
    Daube-Witherspoon, ME
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 179P - 179P
  • [49] Influence of attenuation correction on PET image quality
    Nishio, M.
    Kojima, S.
    Tamai, S.
    Nakagawa, A.
    Tamaki, T.
    Iwata, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S313 - S314
  • [50] MRI for attenuation correction in PET: methods and challenges
    Wagenknecht, Gudrun
    Kaiser, Hans-Juergen
    Mottaghy, Felix M.
    Herzog, Hans
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01): : 99 - 113