Coincidence detection FDG PET in the management of oncological patients: attenuation correction versus non-attenuation correction

被引:6
|
作者
Chan, WL [1 ]
Freund, J [1 ]
Pocock, NA [1 ]
Szeto, E [1 ]
Chan, F [1 ]
Sorensen, BJ [1 ]
McBride, B [1 ]
机构
[1] St Vincents Hosp, Dept Nucl Med, Sydney, NSW, Australia
关键词
fluorodeoxyglucose; Co-PET; attenuation correction; neoplasm;
D O I
10.1097/00006231-200111000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine if attenuation correction (AC) in a dual-head, coincidence, positron emission tomography imaging system (Co-PET) improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation corrected (NAC) images. Thirty patients with known or suspected malignant neoplasms underwent fluorodeoxyglucose (FDG) Co-PET, which was correlated with histopathology, computed tomography (CT) and other conventional imaging modalities and clinical follow-up. The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality in the AC versus NAC Co-PET images. AC Co-PET was statistically superior to NAC Co-PET in relation to lesion detection (P < 0.01) and tumour staging (P < 0.01). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET altered tumour staging in five additional patients (16%) compared to NAC Co-PET. Management was altered in two of these five patients. ((C) 2001 Lippincott Williams & Wilkins).
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [31] Qualitative FDG PET Image Assessment Using Automated Three-Segment MR Attenuation Correction Versus CT Attenuation Correction in a Tertiary Pediatric Hospital: A Prospective Study
    Lyons, Karen
    Seghers, Victor
    Williams, Jennifer L.
    Sorensen, James I. L.
    Paldino, Michael J.
    Krishnamurthy, Rajesh
    Rohren, Eric M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) : 652 - 658
  • [32] Performance of dedicated, non-attenuation corrected FDG-PET in diagnosis and staging of pancreatic cancer (PCA).
    Martin, L
    Fazel, A
    Burton, F
    Fletcher, JW
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 35P - 36P
  • [33] A deep learning approach for 18F-FDG PET attenuation correction
    Fang Liu
    Hyungseok Jang
    Richard Kijowski
    Gengyan Zhao
    Tyler Bradshaw
    Alan B. McMillan
    EJNMMI Physics, 5
  • [34] A deep learning approach for 18F-FDG PET attenuation correction
    Liu, Fang
    Jang, Hyungseok
    Kijowski, Richard
    Zhao, Gengyan
    Bradshaw, Tyler
    McMillan, Alan B.
    EJNMMI PHYSICS, 2018, 5 : 1 - 15
  • [35] Osem and segmented attenuation correction in the calculation of SUVs for 18FDG-PET.
    Visvikis, D
    Townsend, C
    Taylor, LG
    Costa, DC
    Bomanji, J
    Le Rest, C
    Ell, PJ
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 103P - 103P
  • [36] Feasibility of MRI attenuation correction in cardiac-gated FDG-PET
    Lau, Jeffrey
    Laforest, Richard
    Sharma, Shivak
    Priatna, Agus
    McConathy, Jonathan
    Amado, Luciano
    Gropler, Robert
    Woodard, Pamela
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [37] Quantitative carotid PET/MR imaging: clinical evaluation of MR-Attenuation correction versus CT-Attenuation correction in F-18-FDG PET/MR emission data and comparison to PET/CT
    Bini, Jason
    Robson, Philip M.
    Calcagno, Claudia
    Eldib, Mootaz
    Fayad, Zahi A.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 5 (03): : 293 - 304
  • [38] A comparison of MR-based attenuation correction in PET versus SPECT
    Marshall, H. R.
    Stodilka, R. Z.
    Theberge, J.
    Sabondjian, E.
    Legros, A.
    Deans, L.
    Sykes, J. M.
    Thompson, R. T.
    Prato, F. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14): : 4613 - 4629
  • [39] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [40] Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET
    Buvat, I
    Freedman, NMT
    Dilsizian, V
    Bacharach, SL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 848 - 854