Coincidence detection FDG PET in the management of oncological patients: attenuation correction versus non-attenuation correction

被引:6
|
作者
Chan, WL [1 ]
Freund, J [1 ]
Pocock, NA [1 ]
Szeto, E [1 ]
Chan, F [1 ]
Sorensen, BJ [1 ]
McBride, B [1 ]
机构
[1] St Vincents Hosp, Dept Nucl Med, Sydney, NSW, Australia
关键词
fluorodeoxyglucose; Co-PET; attenuation correction; neoplasm;
D O I
10.1097/00006231-200111000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine if attenuation correction (AC) in a dual-head, coincidence, positron emission tomography imaging system (Co-PET) improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation corrected (NAC) images. Thirty patients with known or suspected malignant neoplasms underwent fluorodeoxyglucose (FDG) Co-PET, which was correlated with histopathology, computed tomography (CT) and other conventional imaging modalities and clinical follow-up. The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality in the AC versus NAC Co-PET images. AC Co-PET was statistically superior to NAC Co-PET in relation to lesion detection (P < 0.01) and tumour staging (P < 0.01). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET altered tumour staging in five additional patients (16%) compared to NAC Co-PET. Management was altered in two of these five patients. ((C) 2001 Lippincott Williams & Wilkins).
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [21] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [22] PET system calibration and attenuation correction
    Pawitan, Y
    Kohlmyer, S
    Lewellen, T
    OSullivan, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1249 - 1253
  • [23] Advances in Attenuation Correction Techniques in PET
    Zaidi, Habib
    Montandon, Marie-Louise
    Alavi, Abass
    PET CLINICS, 2007, 2 (02) : 191 - 217
  • [24] An Investigation of Attenuation Correction with Attenuation Map Library in PET Imaging
    Wan, Lu
    Zhang, Yongxue
    Cao, Xiaoqing
    Zeng, Shaoqun
    Xie, Qingguo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3791 - 3793
  • [25] AN INVESTIGATION OF SCATTER IN ATTENUATION CORRECTION FOR PET
    DIGBY, WM
    HOFFMAN, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1038 - 1042
  • [26] PET system calibration and attenuation correction
    Pawitan, Y
    Kohlmyer, S
    Lewellen, T
    OSullivan, F
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1300 - 1304
  • [27] Iterative nonuniform attenuation correction in PET
    Knesaurek, K
    Machac, J
    RADIOLOGY, 1996, 201 : 1099 - 1099
  • [28] PET/CT: Evaluation of The Correction For Attenuation
    Houseni, M.
    Mavi, A.
    Chamroonrat, W.
    Bural, G. G.
    Urhan, M.
    El-Haddad, G.
    Zhuang, H.
    Alavi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S258 - S258
  • [29] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [30] A comparison of singles versus coincidence attenuation corrected FDG PET body images.
    Bedigian, MP
    Smith, R
    Benard, F
    Alavi, A
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 423 - 423