PET attenuation correction using mean attenuation coefficients: A simulation study

被引:2
|
作者
Madsen, MT [1 ]
机构
[1] Univ Iowa, Iowa City, IA 52242 USA
关键词
D O I
10.1109/23.819300
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is desirable to use mean population attenuation coefficients to reduce the statistical fluctuations in measured attenuation maps. In addition, the use of mean attenuation coefficients is also expected to facilitate algorithmic approaches to attenuation correction. Because of the large variation in lung attenuation coefficients both within and among individuals, there is concern about the errors using mean attenuation might create. To test the magnitude of this problem, myocardial metabolic studies were simulated. Attenuated projections were generated from 20 emission and transmission distributions spanning the heart volume. The projections were corrected with both the actual attenuation map and with a mean attenuation map. Quantitative comparisons of the reconstructed images demonstrate no significant differences in the myocardial distributions. However, errors in the lung field exceeded 300% in some regions.
引用
收藏
页码:2172 / 2176
页数:5
相关论文
共 50 条
  • [1] Mean attenuation coefficients for attenuation correction in emission tomography.
    Madsen, MT
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 245 - 245
  • [2] Interpolated Average CT for Attenuation Correction in PET - A Simulation Study
    Mok, Greta S. P.
    Sun, Tao
    Wu, Tung-Hsin
    Chang, Mu-Bai
    Huang, Tzung-Chi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4121 - 4125
  • [3] Interpolated Average CT for Attenuation Correction in PET-A Simulation Study
    Mok, Greta S. P.
    Sun, Tao
    Huang, Tzung-Chi
    Vai, Mang I.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1927 - 1934
  • [4] Emission-based estimation of lung attenuation coefficients in TOF PET/MRI attenuation correction
    Mehranian, Abolfazl
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [5] A PET/CT Attenuation Correction Validation Study Using Microspheres
    Adler, Stephen
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [6] Attenuation correction in PET using consistency information
    Welch, A.
    Campbell, C.
    Clackdoyle, R.
    Natterer, F.
    Hudson, M.
    Bromiley, A.
    Mikecz, P.
    Chillcot, F.
    Dodd, M.
    Hopwood, P.
    Craib, S.
    Gullberg, G.T.
    Sharp, P.
    IEEE Transactions on Nuclear Science, 1998, 45 (6 pt 2): : 3134 - 3141
  • [7] Attenuation correction in PET using consistency information
    Welch, A
    Campbell, C
    Clackdoyle, R
    Natterer, F
    Hudson, M
    Bromiley, A
    Mikecz, P
    Chillcot, F
    Dodd, M
    Hopwood, P
    Craib, S
    Gullberg, GT
    Sharp, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3134 - 3141
  • [8] Transformation of CT-values into linear attenuation coefficients at 511 keV for usage in PET attenuation correction
    Burger, CN
    Schoenes, S
    Goerres, GW
    Lonn, A
    Von Schulthess, GK
    RADIOLOGY, 2001, 221 : 555 - 556
  • [9] Transformation of CT-values into 511 keV attenuation coefficients for usage in PET attenuation correction.
    Burger, C
    Schoenes, S
    Goerres, G
    Buck, A
    Von Schulthess, GK
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 57P - 57P
  • [10] A PET/MRI phantom study using MRI based attenuation correction to account for attenuation of the phantom material
    Rausch, I.
    Valladares, A.
    Beyer, T.
    Unger, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S451 - S452