A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur

被引:11
|
作者
Ferguson, Peter C. [1 ,4 ]
Zdero, Rad [2 ]
Schemitsch, Emil H. [3 ,4 ]
Deheshi, Benjamin M. [1 ,4 ]
Bell, Robert S. [1 ,4 ]
Wunder, Jay S. [1 ,4 ]
机构
[1] Mt Sinai Hosp, Div Orthopaed Surg, Univ Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] St Michaels Hosp, Div Orthopaed Surg, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 08期
关键词
tumor endoprosthesis; uncemented stem; biomechanical analysis; loosening; Femur;
D O I
10.1016/j.arth.2010.12.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to assess the biomechanical parameters of the older Kotz Modular Femur Tibia Reconstruction (Stryker Inc, Mahwah, NJ) stem and the newer Restoration and the unfluted Global Modular Replacement System (Stryker Inc Mahwah, NJ) uncemented stems for use with tumor endoprostheses as well as to assess the optimal reaming technique for insertion of these stems. Fresh-frozen adult femora or composite distal femora were implanted with the uncemented stems. Separate experiments were performed to compare reaming technique and bone resection level. All constructs were mechanically tested for axial compression, lateral bending, and torsional stiffness and torque to failure. Results showed that the biomechanical performance of all the stems were similar with respect to each parameter. Cylindrical reaming was associated with a significantly higher torque to failure than flexible reaming in the diaphysis (P = .006). Newer uncemented stems provide adequate initial biomechanical stability for implantation in the distal femur.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 50 条
  • [21] Biomechanical characterization of double-bundle femoral press-fit fixation techniques
    Ettinger, M.
    Haasper, C.
    Hankemeier, S.
    Hurschler, C.
    Breitmeier, D.
    Krettek, C.
    Jagodzinski, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (03) : 363 - 371
  • [22] An experimental study to investigate biomechanical aspects of the initial stability of press-fit implants
    Berahmani, Sanaz
    Janssen, Dennis
    van Kessel, Sal
    Wolfson, David
    Malefijt, Maarten de Waal
    Buma, Pieter
    Verdonschot, Nico
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 42 : 177 - 185
  • [23] Biomechanical characterization of double-bundle femoral press-fit fixation techniques
    M. Ettinger
    C. Haasper
    S. Hankemeier
    C. Hurschler
    D. Breitmeier
    C. Krettek
    M. Jagodzinski
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 363 - 371
  • [24] Tibial Press-Fit Fixation Technique in Anterior Cruciate Ligament Reconstruction
    Kocabey, Yavuz
    Yildirim, Cem
    Erden, Tunay
    Kaya, Alper
    ARTHROSCOPY TECHNIQUES, 2023, 12 (05): : E737 - E743
  • [25] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    M. Jagodzinski
    K. Scheunemann
    K. Knobloch
    K. Albrecht
    C. Krettek
    C. Hurschler
    J. Zeichen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1281 - 1287
  • [26] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    Jagodzinski, M.
    Scheunemann, K.
    Knobloch, K.
    Albrecht, K.
    Krettek, C.
    Hurschler, C.
    Zeichen, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (12) : 1281 - 1287
  • [27] Letter to the Editor: Increased Anteversion of Press-Fit Femoral Stems Compared with Anatomic Femur
    Wettstein, Michael
    Mouhsine, Elyazid
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (07) : 2051 - 2052
  • [28] Biomechanical testing of quadriceps tendon–patellar bone grafts: an alternative graft source for press-fit anterior cruciate ligament reconstruction?
    Jens Dargel
    Rüdiger Schmidt-Wiethoff
    Thomas Schneider
    Gert-Peter Brüggemann
    Jürgen Koebke
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 265 - 270
  • [29] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Bühler, D.W.
    Oxland, T.R.
    Nolte, L.-P.
    Medical Engineering and Physics, 1997, 19 (02): : 187 - 199
  • [30] Acoustic-Based Spatio-Temporal Learning for Press-Fit Evaluation of Femoral Stem Implants
    Seibold, Matthias
    Hoch, Armando
    Suter, Daniel
    Farshad, Mazda
    Zingg, Patrick O.
    Navab, Nassir
    Fuernstahl, Philipp
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 447 - 456