A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur

被引:11
|
作者
Ferguson, Peter C. [1 ,4 ]
Zdero, Rad [2 ]
Schemitsch, Emil H. [3 ,4 ]
Deheshi, Benjamin M. [1 ,4 ]
Bell, Robert S. [1 ,4 ]
Wunder, Jay S. [1 ,4 ]
机构
[1] Mt Sinai Hosp, Div Orthopaed Surg, Univ Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] St Michaels Hosp, Div Orthopaed Surg, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 08期
关键词
tumor endoprosthesis; uncemented stem; biomechanical analysis; loosening; Femur;
D O I
10.1016/j.arth.2010.12.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to assess the biomechanical parameters of the older Kotz Modular Femur Tibia Reconstruction (Stryker Inc, Mahwah, NJ) stem and the newer Restoration and the unfluted Global Modular Replacement System (Stryker Inc Mahwah, NJ) uncemented stems for use with tumor endoprostheses as well as to assess the optimal reaming technique for insertion of these stems. Fresh-frozen adult femora or composite distal femora were implanted with the uncemented stems. Separate experiments were performed to compare reaming technique and bone resection level. All constructs were mechanically tested for axial compression, lateral bending, and torsional stiffness and torque to failure. Results showed that the biomechanical performance of all the stems were similar with respect to each parameter. Cylindrical reaming was associated with a significantly higher torque to failure than flexible reaming in the diaphysis (P = .006). Newer uncemented stems provide adequate initial biomechanical stability for implantation in the distal femur.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 50 条
  • [31] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Buhler, DW
    Oxland, TR
    Nolte, LP
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (02) : 187 - 199
  • [32] Ex vivo postimplantation biomechanical properties of a press-fit cementless femoral stem with transfixation pin for canine total hip replacement
    Saban, Charles
    Roels, Josephine
    Deprey, Julie
    Massenzio, Michel
    Viguier, Eric
    Cachon, Thibaut
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (11)
  • [33] Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament
    Ettinger, M.
    Liodakis, E.
    Haasper, C.
    Hurschler, C.
    Breitmeier, D.
    Krettek, C.
    Jagodzinski, M.
    UNFALLCHIRURG, 2012, 115 (09): : 811 - 815
  • [34] Femoral press-fit fixation of the hamstring tendons for anterior cruciate ligament reconstruction
    Jagodzinski, M
    Behfar, V
    Hurschler, C
    Albrecht, K
    Krettet, C
    Bosch, U
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (07): : 1723 - 1730
  • [35] Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System
    Visgauss, Julia D.
    Perrin, David L.
    Wilson, David A.
    Griffin, Anthony M.
    Wunder, Jay S.
    Ferguson, Peter C.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (05): : 1333 - 1338
  • [36] A COMPARISON OF CORTICAL STRAIN AFTER CEMENTED AND PRESS-FIT PROXIMAL AND DISTAL FEMORAL REPLACEMENT
    HUA, J
    WALKER, PS
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (05) : 739 - 744
  • [37] The Effects of Unitizing Nail-Plate Constructs in Distal Femur Fractures: A Biomechanical Study
    Mayer, Erik
    Lendhey, Matin
    Kelley, Benjamin
    Shi, Brendan
    Upfill-Brown, Alexander
    Devana, Sai K.
    Brodke, Dane
    Shah, Akash
    Sekimura, Troy
    Gudapati, Varun
    Zukotynski, Brian
    Park, Jeannie
    Witt, Amber R.
    Marciante, Mara
    Mahoney, Jonathan M.
    Bucklen, Brandon S.
    Lee, Christopher
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (08) : 435 - 440
  • [38] Arthroskopische Rekonstruktion des vorderen Kreuzbandes in Press-fit-TechnikArthroscopic reconstruction of anterior cruciate ligament with press-fit technique
    A.M. Halder
    Der Unfallchirurg, 2010, 113 : 635 - 640
  • [39] Patella Strength Characteristics in Cemented vs Press-fit Implants: A Biomechanical Analysis of Initial Stability
    Patel, Akshar H.
    Wilder, J. Heath
    Weldy, John M.
    Ross, Bailey J.
    Kim, Nathaniel E.
    Wang, Hao
    Sanchez, Fernando L.
    Sherman, William F.
    ARTHROPLASTY TODAY, 2022, 14 : 140 - 147
  • [40] Biomechanical testing of quadriceps tendon-patellar bone grafts:: an alternative graft source for press-fit anterior cruciate ligament reconstruction?
    Dargel, J
    Schmidt-Wiethoff, R
    Schneider, T
    Brüggemann, GP
    Koebke, J
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (04) : 265 - 270