A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur

被引:11
|
作者
Ferguson, Peter C. [1 ,4 ]
Zdero, Rad [2 ]
Schemitsch, Emil H. [3 ,4 ]
Deheshi, Benjamin M. [1 ,4 ]
Bell, Robert S. [1 ,4 ]
Wunder, Jay S. [1 ,4 ]
机构
[1] Mt Sinai Hosp, Div Orthopaed Surg, Univ Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] St Michaels Hosp, Div Orthopaed Surg, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 08期
关键词
tumor endoprosthesis; uncemented stem; biomechanical analysis; loosening; Femur;
D O I
10.1016/j.arth.2010.12.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to assess the biomechanical parameters of the older Kotz Modular Femur Tibia Reconstruction (Stryker Inc, Mahwah, NJ) stem and the newer Restoration and the unfluted Global Modular Replacement System (Stryker Inc Mahwah, NJ) uncemented stems for use with tumor endoprostheses as well as to assess the optimal reaming technique for insertion of these stems. Fresh-frozen adult femora or composite distal femora were implanted with the uncemented stems. Separate experiments were performed to compare reaming technique and bone resection level. All constructs were mechanically tested for axial compression, lateral bending, and torsional stiffness and torque to failure. Results showed that the biomechanical performance of all the stems were similar with respect to each parameter. Cylindrical reaming was associated with a significantly higher torque to failure than flexible reaming in the diaphysis (P = .006). Newer uncemented stems provide adequate initial biomechanical stability for implantation in the distal femur.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 50 条
  • [41] Press-Fit Placement of a Rectangular Block Implant in the Resorbed Alveolar Ridge: Surgical and Biomechanical Considerations
    Gazelakis, Efthimios
    Judge, Roy B.
    Palamara, Joseph E. A.
    Subramanian, Shiva
    Nazir, Mohsin
    BIOENGINEERING-BASEL, 2024, 11 (06):
  • [42] RESULTS OF REVISION TOTAL KNEE ARTHROPLASTY USING PRESS-FIT CEMENTLESS STEM
    Iamaguchi, Maurcio Masasi
    Vicente de Castro Filho, Fernando Bley
    Gobbi, Riccardo Gomes
    Passarelli Tirico, Luis Eduardo
    Pecora, Jose Ricardo
    Camanho, Gilberto Luis
    ACTA ORTOPEDICA BRASILEIRA, 2013, 21 (01): : 23 - 26
  • [43] Preliminary clinical outcome of the femur RetroButton combined with glaze allergenic cortical press-fit bolt fixation
    蔡谞
    ChinaMedicalAbstracts(Surgery), 2011, 20 (02) : 108 - 109
  • [44] Anterior cruciate ligament reconstruction using quadriceps tendon autograft and press-fit fixation
    Barie, A.
    Kargus, S.
    Huber, J.
    Schmitt, H.
    Streich, N. A.
    UNFALLCHIRURG, 2010, 113 (08): : 629 - 634
  • [45] COMPARISON OF THE STABILITY OF PRESS-FIT HIP-PROSTHESIS FEMORAL STEMS USING A SYNTHETIC MODEL FEMUR
    MCKELLOP, H
    EBRAMZADEH, E
    NIEDERER, PG
    SARMIENTO, A
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) : 297 - 305
  • [46] Bone density and functional results after femoral revision with a cementless press-fit stem
    Canovas, F.
    Roche, O.
    Girard, J.
    Bonnomet, F.
    Goldschild, M.
    Le Beguec, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 283 - 287
  • [47] Nail-Plate Constructs for Treating Distal Femur Fractures: A Systematic Review of Biomechanical Studies
    Anaspure, Omkar S.
    Patel, Shiv
    Baumann, Anthony N.
    Anastasio, Albert T.
    Pean, Christian
    DeBaun, Malcolm R.
    SURGERIES, 2024, 5 (03): : 799 - 816
  • [48] Initial stability of cementless acetabular cups: press-fit and screw fixation interaction—an in vitro biomechanical study
    Tabata T.
    Kaku N.
    Hara K.
    Tsumura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (3) : 497 - 502
  • [49] Cement and press-fit humeral stem fixation provides similar results in rheumatoid patients
    Rahme, Hans
    Mattsson, Per
    Wikblad, Lars
    Larsson, Sune
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) : 28 - 32
  • [50] Assessment of a fictitious domain method for patient-specific biomechanical modelling of press-fit orthopaedic implantation
    Kallivokas, L. F.
    Na, S-W
    Ghattas, O.
    Jaramaz, B.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) : 501 - 516