Acoustic-Based Spatio-Temporal Learning for Press-Fit Evaluation of Femoral Stem Implants

被引:3
|
作者
Seibold, Matthias [1 ,2 ]
Hoch, Armando [3 ]
Suter, Daniel [3 ]
Farshad, Mazda [3 ]
Zingg, Patrick O. [3 ]
Navab, Nassir [1 ]
Fuernstahl, Philipp [2 ,3 ]
机构
[1] Tech Univ Munich, Comp Aided Med Procedures CAMP, D-85748 Munich, Germany
[2] Univ Zurich, Univ Hosp Balgrist, Res Orthoped Comp Sci ROCS, CH-8008 Zurich, Switzerland
[3] Univ Zurich, Balgrist Univ Hosp, CH-8008 Zurich, Switzerland
关键词
Spatio-temporal learning; Acoustic sensing; Total hip arthroplasty; Femoral stem insertion; PERIPROSTHETIC FRACTURES; CEMENTLESS;
D O I
10.1007/978-3-030-87202-1_43
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work, we propose a method utilizing tool-integrated vibroacoustic measurements and a spatio-temporal learning-based framework for the detection of the insertion endpoint during femoral stem implantation in cementless Total Hip Arthroplasty (THA). In current practice, the optimal insertion endpoint is intraoperatively identified based on surgical experience and dependent on a subjective decision. Leveraging spectogram features and time-variant sequences of acoustic hammer blow events, our proposed solution can give real-time feedback to the surgeon during the insertion procedure and prevent adverse events in clinical practice. To validate our method on real data, we built a realistic experimental human cadaveric setup and acquired acoustic signals of hammer blows during broaching the femoral stem cavity with a novel inserter tool which was enhanced by contact microphones. The optimal insertion endpoint was determined by a standardized preoperative plan following clinical guidelines and executed by a board-certified surgeon. We train and evaluate a Long-Term Recurrent Convolutional Neural Network (LRCN) on sequences of spectrograms to detect a reached target press fit corresponding to a seated implant. The proposed method achieves an overall per-class recall of 93.82 +/- 5.11% for detecting an ongoing insertion and 70.88 +/- 11.83% for identifying a reached target press fit for five independent test specimens. The obtained results open the path for the development of automated systems for intra-operative decision support, error prevention and robotic applications in hip surgery.
引用
收藏
页码:447 / 456
页数:10
相关论文
共 50 条
  • [1] STRAINS AND MICROMOTIONS OF PRESS-FIT FEMORAL STEM PROSTHESES
    WALKER, PS
    SCHNEEWEIS, D
    MURPHY, S
    NELSON, P
    JOURNAL OF BIOMECHANICS, 1987, 20 (07) : 693 - 702
  • [2] Influence of press-fit parameters on the primary stability of uncemented femoral resurfacing implants
    Gebert, A.
    Peters, J.
    Bishop, N. E.
    Westphal, F.
    Morlock, M. M.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) : 160 - 164
  • [3] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Attila Pavlik
    Péter Hidas
    Tibor Czigány
    István Berkes
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 528 - 533
  • [4] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Pavlik, A
    Hidas, P
    Czigány, T
    Berkes, I
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (06) : 528 - 533
  • [5] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Bühler, D.W.
    Oxland, T.R.
    Nolte, L.-P.
    Medical Engineering and Physics, 1997, 19 (02): : 187 - 199
  • [6] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Buhler, DW
    Oxland, TR
    Nolte, LP
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (02) : 187 - 199
  • [7] Bone density and functional results after femoral revision with a cementless press-fit stem
    Canovas, F.
    Roche, O.
    Girard, J.
    Bonnomet, F.
    Goldschild, M.
    Le Beguec, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 283 - 287
  • [8] Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis
    Blankstein, Michael
    Haimes, Mark A.
    Nelms, Nathaniel J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (20) : E1279 - E1290
  • [9] Early radiological and functional outcomes for a cementless press-fit design modular femoral stem revision system
    Hancock, Douglas S.
    Sharplin, Paul K.
    Larsen, Peter D.
    Phillips, Fredrick T. S.
    HIP INTERNATIONAL, 2019, 29 (01) : 35 - 40
  • [10] A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur
    Ferguson, Peter C.
    Zdero, Rad
    Schemitsch, Emil H.
    Deheshi, Benjamin M.
    Bell, Robert S.
    Wunder, Jay S.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1373 - 1379