Noncemented press-fit femoral stems predominate in total hip arthroplasty for all age groups with generally excellent long-term survivorship. The 2021 American Joint Replacement Registry reports that 96% of all elective primary total hip arthroplasties used noncemented femoral implant fixation.(1) Today, there are many styles of press-fit stems, each with supposed benefits, based on a range of design philosophies. Design aspects to consider when selecting a stem are numerous, including stem geometry, stem length, collared or collarless, material properties, and surface structure. Although most stem designs demonstrate excellent results, the differences in stem designs are intimately linked to additional factors such as ease of use/ implantation, percentage of surface osseointegration, overall bone removal versus bone stock preservation, subsequent femoral stress shielding, and consideration of complexity of later revision. A surgeon with a broad understanding and appreciation of femoral stem designs should be prepared to select between the multitude of options to best serve individual patients.
引用
收藏
页码:E1279 / E1290
页数:12
相关论文
共 50 条
  • [1] Risk Factors for Femoral Fracture after Canine Press-Fit Cementless Total Hip Arthroplasty
    Ganz, Seth Mathus
    Jackson, Joshua
    VanEnkevort, Bruce
    VETERINARY SURGERY, 2010, 39 (06) : 688 - 695
  • [2] Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems
    Canovas, F.
    LeBeguec, P.
    Batard, J.
    Gaillard, F.
    Dagneaux, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 579 - 581
  • [3] TORSIONAL FIXATION OF THE FEMORAL COMPONENT IN TOTAL HIP-ARTHROPLASTY - THE EFFECT OF SURGICAL PRESS-FIT TECHNIQUE
    SUGIYAMA, H
    WHITESIDE, LA
    ENGH, CA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (275) : 187 - 193
  • [4] Press-fit hip arthroplasty - A European alternative
    Romagnoli, S
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 108 - 112
  • [5] CEMENTLESS TITANIUM PRESS-FIT FEMORAL PROSTHESIS IN THE DOG
    ANDERSON, GI
    SUMNERSMITH, G
    COCKSHUTT, J
    VETERINARY SURGERY, 1988, 17 (01) : 27 - 27
  • [6] Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study
    Russell, Robert D.
    Huo, Michael H.
    Rodrigues, Danieli C.
    Kosmopoulos, Victor
    TECHNOLOGY AND HEALTH CARE, 2016, 24 (06) : 865 - 872
  • [7] EXPERIMENTAL AND NUMERICAL VALIDATION OF A COMMERCIAL PRESS-FIT FEMORAL PROSTHESIS
    Duarte, Ricardo J. J.
    Ramos, Antonio
    Relvas, Carlos
    Completo, Antonio
    Simoes, Jose A.
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [8] Revision Total Hip Arthroplasty Using a Tapered, Press-Fit Cement less Revision Stem in Elderly Patients
    Chang, Jun-Dong
    Kim, Tae-Young
    Rao, Murari Bhaskar
    Lee, Sang-Soo
    Kim, In-Sung
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1045 - 1049
  • [9] Comparison of femoral stem subsidence between three types of press-fit cementless total hip replacement in dogs
    Mitchell, Megan M.
    Hudson, Caleb C.
    Beale, Brian S.
    VETERINARY SURGERY, 2020, 49 (04) : 787 - 793
  • [10] RESULTS OF REVISION TOTAL KNEE ARTHROPLASTY USING PRESS-FIT CEMENTLESS STEM
    Iamaguchi, Maurcio Masasi
    Vicente de Castro Filho, Fernando Bley
    Gobbi, Riccardo Gomes
    Passarelli Tirico, Luis Eduardo
    Pecora, Jose Ricardo
    Camanho, Gilberto Luis
    ACTA ORTOPEDICA BRASILEIRA, 2013, 21 (01): : 23 - 26