A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur

被引:11
|
作者
Ferguson, Peter C. [1 ,4 ]
Zdero, Rad [2 ]
Schemitsch, Emil H. [3 ,4 ]
Deheshi, Benjamin M. [1 ,4 ]
Bell, Robert S. [1 ,4 ]
Wunder, Jay S. [1 ,4 ]
机构
[1] Mt Sinai Hosp, Div Orthopaed Surg, Univ Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] St Michaels Hosp, Div Orthopaed Surg, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 08期
关键词
tumor endoprosthesis; uncemented stem; biomechanical analysis; loosening; Femur;
D O I
10.1016/j.arth.2010.12.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to assess the biomechanical parameters of the older Kotz Modular Femur Tibia Reconstruction (Stryker Inc, Mahwah, NJ) stem and the newer Restoration and the unfluted Global Modular Replacement System (Stryker Inc Mahwah, NJ) uncemented stems for use with tumor endoprostheses as well as to assess the optimal reaming technique for insertion of these stems. Fresh-frozen adult femora or composite distal femora were implanted with the uncemented stems. Separate experiments were performed to compare reaming technique and bone resection level. All constructs were mechanically tested for axial compression, lateral bending, and torsional stiffness and torque to failure. Results showed that the biomechanical performance of all the stems were similar with respect to each parameter. Cylindrical reaming was associated with a significantly higher torque to failure than flexible reaming in the diaphysis (P = .006). Newer uncemented stems provide adequate initial biomechanical stability for implantation in the distal femur.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 50 条
  • [1] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Pavlik, A
    Hidas, P
    Czigány, T
    Berkes, I
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (06) : 528 - 533
  • [2] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Attila Pavlik
    Péter Hidas
    Tibor Czigány
    István Berkes
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 528 - 533
  • [3] Distal femur resection with endoprosthetic reconstruction
    Bickels, J
    Wittig, JC
    Kollender, Y
    Henshaw, RM
    Kellar-Graney, KL
    Meller, I
    Malawer, MM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (400) : 225 - 235
  • [4] Changes in bone mineral density of the distal femur after revision total knee arthroplasty with metaphyseal press-fit stem
    Jensen C.L.
    Petersen M.M.
    Schrøder H.M.
    Lund B.
    Journal of Orthopaedics and Traumatology, 2010, 11 (3) : 143 - 148
  • [5] Biomechanical comparison of two surgical techniques for press-fit reconstruction of the posterolateral complex of the knee
    Panzica, Martin
    Janzik, Janne
    Bobrowitsch, Evgenij
    Krettek, Christian
    Hawi, Nael
    Hurschler, Christof
    Jagodzinski, Michael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (11) : 1579 - 1588
  • [6] Biomechanical comparison of two surgical techniques for press-fit reconstruction of the posterolateral complex of the knee
    Martin Panzica
    Janne Janzik
    Evgenij Bobrowitsch
    Christian Krettek
    Nael Hawi
    Christof Hurschler
    Michael Jagodzinski
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1579 - 1588
  • [7] Arthroscopic ACL Reconstruction in Press-Fit Technique
    Halder, Andreas M.
    Marx, Axel
    TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 141 - 144
  • [8] Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement
    Christopher, Scott A.
    Kim, Stanley E.
    Roe, Simon
    Pozzi, Antonio
    VETERINARY JOURNAL, 2016, 214 : 7 - 9
  • [9] The effect of a radial neck notch on press-fit stem stability: a biomechanical study on 7 cadavers
    Shukla, Dave R.
    Sahu, Dipit C.
    Fitzsimmons, James S.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (03) : 523 - 529
  • [10] Increased Anteversion of Press-fit Femoral Stems Compared With Anatomic Femur
    Emerson, Roger H., Jr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) : 477 - 481