Acoustic-Based Spatio-Temporal Learning for Press-Fit Evaluation of Femoral Stem Implants

被引:3
|
作者
Seibold, Matthias [1 ,2 ]
Hoch, Armando [3 ]
Suter, Daniel [3 ]
Farshad, Mazda [3 ]
Zingg, Patrick O. [3 ]
Navab, Nassir [1 ]
Fuernstahl, Philipp [2 ,3 ]
机构
[1] Tech Univ Munich, Comp Aided Med Procedures CAMP, D-85748 Munich, Germany
[2] Univ Zurich, Univ Hosp Balgrist, Res Orthoped Comp Sci ROCS, CH-8008 Zurich, Switzerland
[3] Univ Zurich, Balgrist Univ Hosp, CH-8008 Zurich, Switzerland
关键词
Spatio-temporal learning; Acoustic sensing; Total hip arthroplasty; Femoral stem insertion; PERIPROSTHETIC FRACTURES; CEMENTLESS;
D O I
10.1007/978-3-030-87202-1_43
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work, we propose a method utilizing tool-integrated vibroacoustic measurements and a spatio-temporal learning-based framework for the detection of the insertion endpoint during femoral stem implantation in cementless Total Hip Arthroplasty (THA). In current practice, the optimal insertion endpoint is intraoperatively identified based on surgical experience and dependent on a subjective decision. Leveraging spectogram features and time-variant sequences of acoustic hammer blow events, our proposed solution can give real-time feedback to the surgeon during the insertion procedure and prevent adverse events in clinical practice. To validate our method on real data, we built a realistic experimental human cadaveric setup and acquired acoustic signals of hammer blows during broaching the femoral stem cavity with a novel inserter tool which was enhanced by contact microphones. The optimal insertion endpoint was determined by a standardized preoperative plan following clinical guidelines and executed by a board-certified surgeon. We train and evaluate a Long-Term Recurrent Convolutional Neural Network (LRCN) on sequences of spectrograms to detect a reached target press fit corresponding to a seated implant. The proposed method achieves an overall per-class recall of 93.82 +/- 5.11% for detecting an ongoing insertion and 70.88 +/- 11.83% for identifying a reached target press fit for five independent test specimens. The obtained results open the path for the development of automated systems for intra-operative decision support, error prevention and robotic applications in hip surgery.
引用
收藏
页码:447 / 456
页数:10
相关论文
共 50 条
  • [21] Excellent results of a femoral press-fit stem cemented with a thin mantle:: 116 hips followed for 11-18 years
    Gjengedal, Erling
    Uppheim, Gisle
    Bjerkholt, Havard
    Hovik, Oystein
    Reikeras, Olav
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (03): : 279 - 284
  • [22] Spatio-temporal visual learning for home-based monitoring
    Djenouri, Youcef
    Belbachir, Ahmed Nabil
    Cano, Alberto
    Belhadi, Asma
    INFORMATION FUSION, 2024, 101
  • [23] Graph signal reconstruction based on spatio-temporal features learning
    Yang, Jie
    Shi, Ce
    Chu, Yueyan
    Guo, Wenbin
    DIGITAL SIGNAL PROCESSING, 2024, 148
  • [24] Attention-based spatio-temporal dependence learning network
    Ma, Qianli
    Tian, Shuai
    Wei, Jia
    Wang, Jiabing
    Ng, Wing W. Y.
    INFORMATION SCIENCES, 2019, 503 (92-108) : 92 - 108
  • [25] Ex vivo postimplantation biomechanical properties of a press-fit cementless femoral stem with transfixation pin for canine total hip replacement
    Saban, Charles
    Roels, Josephine
    Deprey, Julie
    Massenzio, Michel
    Viguier, Eric
    Cachon, Thibaut
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (11)
  • [26] A Proposal and Evaluation of Spatio-Temporal Reconstruction Method Based on DRAMA
    Kon, Tatsuya
    Obi, Takashi
    Tashima, Hideaki
    Ohyama, Nagaaki
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2648 - 2652
  • [27] Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
    Cooperman, Charlotte
    Wiznia, Daniel
    Kunsel, Kunsel
    Roytman, Gregory
    Ani, Lidia
    Pratola, Donald
    Lee, Gwo-Chin
    Tommasini, Steven
    Bernstein, Jenna
    ARTHROPLASTY TODAY, 2022, 18 : 45 - 51
  • [28] A Secure Communication Scheme Based on Spatio-temporal Dynamics of Underwater Acoustic Channel
    Su, Yishan
    Pan, Pan
    Fan, Rong
    Yang, Sidan
    Dou, Fei
    ICC 2024 - IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, 2024, : 3334 - 3339
  • [29] Mid-term results of a cementless hip stem in femoral revision: how much diaphyseal press-fit do we need?
    Herold, Dirk
    Kuttner, Axel
    Dreyer, Lutz
    Eingartner, Christoph
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (04) : 1813 - 1820
  • [30] Mid-term results of a cementless hip stem in femoral revision: how much diaphyseal press-fit do we need?
    Dirk Herold
    Axel Kuttner
    Lutz Dreyer
    Christoph Eingartner
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1813 - 1820