Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses

被引:14
|
作者
Kirsch, Katharina [1 ]
Detilleux, Johann [2 ]
Serteyn, Didier [1 ]
Sandersen, Charlotte [1 ]
机构
[1] Univ Liege, Fac Vet Med, Dept Compan Anim & Equids, Equine Clin, Liege, Belgium
[2] Univ Liege, Fac Vet Med, Dept Quantitat Genet, Liege, Belgium
来源
PLOS ONE | 2019年 / 14卷 / 02期
关键词
ACID-BASE; STATISTICAL-METHODS; HEMOGLOBIN; AGREEMENT; INTERFERENCE; POTASSIUM; PRECISION;
D O I
10.1371/journal.pone.0211104
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Portable blood gas analyzers are used to facilitate diagnosis and treatment of disorders related to disturbances of acid-base and electrolyte balance in the ambulatory care of equine patients. The aim of this study was to determine whether 2 portable analyzers produce results in agreement with a stationary analyzer. Blood samples from 23 horses hospitalized for various medical reasons were included in this prospective study. Blood gas analysis and electrolyte concentrations measured by the portable analyzers VetStat and epoc were compared to those produced by the cobas b 123 analyzer via concordance analysis, Passing-Bablok regression and Bland-Altman analysis. Limits of agreement indicated relevant bias between the VetStat and cobas b 123 for partial pressure of oxygen (pO(2); 27.5-33.8 mmHg), sodium ([Na+]; 4.3-21.6 mmol/L) and chloride concentration ([CI-]; 0.3-7.9 mmol/L) and between the epoc and cobas b 123 for pH (0.070-0.022), partial pressure of carbon dioxide (pCO(2); 3.6-7.3 mmHg), pO(2) (36.2-32.7 mmHg) and [Na+] (0.38.1 mmol/L). The VetStat analyzer yielded results that were in agreement with the cobas b 123 analyzer for determination of pH, pCO(2), bicarbonate ([HCO3-]) and potassium concentration [K+], while the epoc analyzer achieved acceptable agreement for [HCO3] and [K+]. The VetStat analyzer may be useful in performing blood gas analysis in equine samples but analysis of [Na+], [Cl-] and pO(2) should be interpreted with caution. The epoc delivered reliable results for [HCO3] and [K+], while results for pH, pCO(2), pO(2) and [Na+] should be interpreted with caution.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] How and when to measure pH in IVF culture media: validation of a portable blood gas analyzer in two IVF culture dishes for time lapse and conventional incubators
    Lucie Chansel-Debordeaux
    Manon Carles
    Jessika Moreau
    Chloé Depuydt
    Sylvie Gallo
    Edwige Genvrin
    Roger Léandri
    Nicolas Gatimel
    [J]. Journal of Assisted Reproduction and Genetics, 2023, 40 : 1677 - 1687
  • [42] How and when to measure pH in IVF culture media: validation of a portable blood gas analyzer in two IVF culture dishes for time lapse and conventional incubators
    Chansel-Debordeaux, Lucie
    Carles, Manon
    Moreau, Jessika
    Depuydt, Chloe
    Gallo, Sylvie
    Genvrin, Edwige
    Leandri, Roger
    Gatimel, Nicolas
    [J]. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2023, 40 (07) : 1677 - 1687
  • [43] Blood cyanide determination in two cases of fatal intoxication: Comparison between headspace gas chromatography and a spectrophotometric method
    Gambaro, Veniero
    Arnoldi, Sebastiano
    Casagni, Eleonora
    Dell'Acqua, Lucia
    Pecoraro, Chiara
    Froldi, Rino
    [J]. JOURNAL OF FORENSIC SCIENCES, 2007, 52 (06) : 1401 - 1404
  • [44] Establishment of Hy-Line commercial laying hen whole blood gas and biochemistry reference intervals utilizing portable i-STAT1 clinical analyzer
    Sauer, Z. C.
    Taylor, K.
    Wolc, A.
    Viall, A.
    O'Sullivan, N.
    Fulton, J. E.
    Rubinoff, I
    Schaal, T.
    Sato, Y.
    [J]. POULTRY SCIENCE, 2019, 98 (06) : 2354 - 2359
  • [45] Comparison of continuous intraarterial blood gas analysis and transcutaneous monitoring to measure oxygen partial pressure during one-lung ventilation
    Takeshi Umegaki
    Osamu Kikuchi
    Kiichi Hirota
    Takehiko Adachi
    [J]. Journal of Anesthesia, 2007, 21 : 110 - 111
  • [46] Comparison of continuous intraarterial blood gas analysis and transcutaneous monitoring to measure oxygen partial pressure during one-lung ventilation
    Umegaki, Takeshi
    Kikuchi, Osamu
    Hirota, Kiichi
    Adachi, Takehiko
    [J]. JOURNAL OF ANESTHESIA, 2007, 21 (01) : 110 - 111
  • [47] CLINICAL COMPARISON OF ONE INVITRO AND 3 IN-LINE BLOOD-GAS PO2 SENSORS DURING CARDIOPULMONARY BYPASS
    POSLAD, SJ
    PEARSON, DT
    MURRAY, A
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (03): : 249 - 259
  • [48] Newborn Screening for Congenital Hypothyroidism-Clinical Evaluation and Comparison of Two Different Test Kits for the Determination of TSH in Dried Blood Samples on Two Different Platforms
    Fingerhut, Ralph
    [J]. INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2021, 7 (03)
  • [49] Method comparison and validation of a prototype device for measurement of ionized calcium concentrations cow-side against a point-of-care instrument and a benchtop blood-gas analyzer reference method
    Neves, R. C.
    Stokol, T.
    Bach, K. D.
    McArt, J. A. A.
    [J]. JOURNAL OF DAIRY SCIENCE, 2018, 101 (02) : 1334 - 1343
  • [50] Research Note: Comparison of chicken blood chemistry and electrolyte parameters between the portable i-STAT1 clinical analyzer and VetScan VS2 serum biochemistry panel using Hy-Line commercial white-egg laying hens
    Sauer, Z. C.
    Taylor, K.
    Wolc, A.
    Viall, A.
    Fulton, J. E.
    Settar, P.
    Rubinoff, I
    Schaal, T.
    Sato, Y.
    [J]. POULTRY SCIENCE, 2020, 99 (07) : 3487 - 3490