Establishment of Hy-Line commercial laying hen whole blood gas and biochemistry reference intervals utilizing portable i-STAT1 clinical analyzer

被引:7
|
作者
Sauer, Z. C. [1 ]
Taylor, K. [2 ]
Wolc, A. [2 ,3 ]
Viall, A. [1 ]
O'Sullivan, N. [2 ]
Fulton, J. E. [2 ]
Rubinoff, I [2 ]
Schaal, T. [2 ]
Sato, Y. [1 ]
机构
[1] Iowa State Univ, Coll Vet Med, Ames, IA 50010 USA
[2] Hy Line Int, Dallas Ctr, IA 50063 USA
[3] Iowa State Univ, Dept Anim Sci, Ames, IA 50011 USA
关键词
blood gas; blood chemistry; laying hen; colored egg layer; i-STAT1; CHEMISTRY; CHICKENS;
D O I
10.3382/ps/pey600
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Blood gas and biochemistry reference intervals were established for 3 genetically distinct commercial varieties (CVs) of Hy-Line laying hens: 2 brown-egg layers (Hy-Line Brown, Hy-Line Silver Brown) and a tint-egg layer (Hy-Line Sonia) utilizing the i-STAT1 analyzer. Each respective variety of laying hen was sampled on a replicate cycle of 2 wk for a total of 6 replicates (35 to 46 wk of age). Blood samples were obtained in the production house from the brachial vein, and subsequently analyzed by the i-STAT1 portable device. i-STAT1 clinical analyzer reports blood gas and biochemistry values for the following parameters: pH, partial pressure of carbon dioxide (pvCO(2), mm Hg), partial pressure of oxygen (pvO(2), mm Hg), bicarbonate (HCO3, mmol/L), base excess (BE, mmol/L), saturation of oxygen on hemoglobin (sO(2)%), glucose (Glu, mg/dL), sodium (Na, mmol/L), potassium (K, mmol/L), total concentration of carbon dioxide (TCO2, mmol/L), ionized calcium (iCa, mmol/L), hematocrit (Hct % packed cell volume [PCV]), hemoglobin (Hb, g/dL). A total of 1,800 individual hen i-STAT1 records were utilized in the establishment of reference interval values for the 13 parameters between the 3 CVs. Statistical analysis via ANOVA and Tukey's test revealed significant line differences for all 13 blood gas and chemistry parameters measured, with particularly interesting results in iCa. The blood gas and chemistry parameters collected in this study will serve as reference intervals to set the framework for potential future correlations to genetic markers, physiological abnormalities, and production performance.
引用
收藏
页码:2354 / 2359
页数:6
相关论文
共 4 条
  • [1] Commercial Hy-Line W-36 pullet and laying hen venous blood gas and chemistry profiles utilizing the portable i-STAT®1 analyzer
    Schaal, T. P.
    Arango, J.
    Wolc, A.
    Brady, J. V.
    Fulton, J. E.
    Rubinoff, I.
    Ehr, I. J.
    Persia, M. E.
    O'Sullivan, N. P.
    [J]. POULTRY SCIENCE, 2016, 95 (02) : 466 - 471
  • [2] Evaluation and establishment of reference intervals using the i-STAT1 blood chemistry analyzer in turkeys
    Ripplinger, Eliza N.
    Gruber, Erika J.
    Correa, Maria T.
    Martin, Michael P.
    Crespo, Rocio
    [J]. POULTRY SCIENCE, 2023, 102 (08)
  • [3] Research Note: Comparison of chicken blood chemistry and electrolyte parameters between the portable i-STAT1 clinical analyzer and VetScan VS2 serum biochemistry panel using Hy-Line commercial white-egg laying hens
    Sauer, Z. C.
    Taylor, K.
    Wolc, A.
    Viall, A.
    Fulton, J. E.
    Settar, P.
    Rubinoff, I
    Schaal, T.
    Sato, Y.
    [J]. POULTRY SCIENCE, 2020, 99 (07) : 3487 - 3490
  • [4] Establishment of Age-Specific Whole Blood Biochemistry and Gas Reference Intervals in Broiler Chickens Using the i-STAT and the Vetscan VS2 Portable Analyzers
    Ruiz-Jimenez, F.
    Gruber, E.
    Correa, M.
    Crespo, R.
    [J]. AVIAN DISEASES, 2022, 66 (01) : 95 - 100