摘要
Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [21] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    [J]. JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [22] Cancer risk estimation in Digital Breast Tomosynthesis using GEANT4 Monte Carlo simulations and voxel phantoms
    Ferreira, P.
    Baptista, M.
    Di Maria, S.
    Vaz, P.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 717 - 723
  • [23] IMRT treatment Monitor Unit verification using absolute calibrated BEAMnrc and Geant4 Monte Carlo simulations
    Oborn, B. M.
    Williams, M.
    Bailey, M.
    Carolan, M. G.
    [J]. XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [24] Investigation of Perylene as a Converter Material for Fast Neutron Detection and Spectroscopy Using GEANT4 Monte Carlo Simulations
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Venkatesan, A.
    Devan, K.
    Madhusoodanan, K.
    [J]. ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 : 189 - 197
  • [25] A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit
    Incerti, S.
    Gault, N.
    Habchi, C.
    Lefaix, J. L.
    Moretto, Ph.
    Poncy, J. L.
    Pouthier, T.
    Seznec, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 327 - 329
  • [26] Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations
    Depauw, Nicolas
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2407 - 2421
  • [27] Validating Geant4 with Monte Carlo simulations in the context of nuclear disarmament verification
    Kreutle, Manuel
    Borella, Alessandro
    Hebel, Simon
    Kirchner, Gerald
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [28] Polarized electron Mott scattering model for the Geant4 Monte Carlo toolkit
    Dragowski, M.
    Adamus, M.
    Weber, G.
    Wlodarczyk, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 488 : 37 - 42
  • [29] Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code Geant4
    Larsson, S
    Svensson, R
    Gudowska, I
    Ivanchenko, V
    Brahme, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 503 - 507
  • [30] Simulations of the HEX payload using Geant4
    Sudhakar, Manju
    Vadawale, Santosh
    Sreekurnar, P.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2351 - +