Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

被引:6
|
作者
Gerlach, M. [1 ]
Krumrey, M. [1 ]
Cibik, L. [1 ]
Mueller, P. [1 ]
Ulm, G. [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
Geant4; Synchrotron radiation; CdTe detector; Calibration; Polarization; X-RAY RANGE; DETECTORS; PERFORMANCE; CALIBRATION; ACCURACY; BEAMLINE; COMPTON; TOOLKIT; PHYSICS;
D O I
10.1016/j.nima.2009.06.062
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [41] Comparison Among Homogeneous Models and a Voxel Model on Mammography: a Monte Carlo Study Using the GEANT4 code
    Cassola, Vagner F.
    Hoff, Gabriela
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2428 - +
  • [42] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Dae-Hyun Kim
    Young Nam Kang
    Tae-Suk Suh
    Jungwook Shin
    Jong Won Kim
    Seung Hoon Yoo
    Seyjoon Park
    Sang Hoon Lee
    Sungkoo Cho
    Dongho Shin
    Dae Yong Kim
    Se Byeong Lee
    [J]. Journal of the Korean Physical Society, 2012, 61 : 1125 - 1130
  • [43] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [44] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [45] Dosimetric comparison between different radiotherapy protocols for prostate cancer using Geant4 Monte Carlo simulation
    Syahir, M. K.
    Fahmi, M. R.
    Hashikin, N. A. A.
    [J]. 11TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS (ISMP) 2019, 2020, 1497
  • [46] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [47] A Comparison of Geant4 and DPM for 4D Monte Carlo of Lung IMRT
    Hancox, C.
    Seco, J.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [48] Calculation of absorbed dose factors for Re-186 in radiation synovectomy using Monte Carlo simulation with Geant4
    Lagares, L. C.
    Veloza, L. S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1842 - 1845
  • [49] Monte Carlo study of X-ray grazing incidence microscopy using Geant4
    Li, Wenjie
    Xu, Jie
    Yang, Cheng
    Li, Mingtao
    Wang, Xin
    Zhang, Xing
    Mu, Baozhong
    [J]. OPTICS EXPRESS, 2023, 31 (22) : 35453 - 35470
  • [50] The simulation of ultracold neutron experiments using GEANT4
    Atchison, F
    Brys, T
    Daum, M
    Fierlinger, P
    Fomin, A
    Henneck, R
    Kirch, K
    Kuzniak, M
    Pichlmaier, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 552 (03): : 513 - 521