Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

被引:6
|
作者
Gerlach, M. [1 ]
Krumrey, M. [1 ]
Cibik, L. [1 ]
Mueller, P. [1 ]
Ulm, G. [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
Geant4; Synchrotron radiation; CdTe detector; Calibration; Polarization; X-RAY RANGE; DETECTORS; PERFORMANCE; CALIBRATION; ACCURACY; BEAMLINE; COMPTON; TOOLKIT; PHYSICS;
D O I
10.1016/j.nima.2009.06.062
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [31] Monte Carlo study of a double-scattering Compton camera with GEANT4
    Seo, Hee
    An, So Hyun
    Kim, Jong Kyung
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 314 - 317
  • [32] A CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
    Henderson, N.
    Murakami, K.
    Amako, K.
    Asai, M.
    Aso, T.
    Dotti, A.
    Kimura, A.
    Gerritsen, M.
    Kurashige, H.
    Perl, J.
    Sasaki, T.
    [J]. SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [33] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [34] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    [J]. Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [35] Monte Carlo studies of the Tunisian gamma irradiation facility using GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    Mannai, K
    Trabelsi, A
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (02) : 170 - 177
  • [36] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    [J]. BioMedical Engineering OnLine, 13
  • [37] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [38] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [39] Geant4 Monte Carlo Simulations of the belt proton radiation environment on board the international space Station/Columbus
    Ersmark, Tore
    Carlson, Per
    Daly, Earnorm
    Fuglesang, Christer
    Gudowska, Irena
    Lund-Jensen, Bengt
    Nierninen, Petteri
    Pearce, Mark
    Santin, Giovanni
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) : 1444 - 1453
  • [40] BETA-EFFICIENCY OF A TYPICAL GAS-FLOW IONIZATION CHAMBER USING GEANT4 MONTE CARLO SIMULATIONS
    Hussain, Abid
    Mirza, Sikander M.
    Mirza, Nasir M.
    Siddique, Muhammad T.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2011, 26 (03): : 193 - 200