Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit

被引:2
|
作者
Boudjella, Manal Yasmine [1 ]
Belbachir, Ahmed Hafid [1 ]
Dib, Samy Anis Amine [1 ]
Meftah, Mustapha [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Versailles St Quentin En Yvelines, Sorbonne Univ, Univ Paris Saclay, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Solar spectral irradiance; Atmospheric transmittance; Radiative transfer models; Geant4; MYSTIC; Beer-Lambert law; RADIATIVE-TRANSFER; SOLAR IRRADIANCE; MULTIPLE-SCATTERING; MODELS; SIMULATION; RETRIEVAL; DATABASE; VERSION; CODE;
D O I
10.1016/j.jastp.2023.106077
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The spectral direct normal irradiance (DNI) of the surface spectral irradiance, with a spectral resolution of 1 nm in the range of 280-1600 nm, and 5 nm in the range of 1600-3000 nm, has been calculated for the first time with the Geant4 Monte Carlo simulation toolkit using the US Standard Atmosphere 1976 model and the reference extraterrestrial solar spectrum SOLAR-ISS. The atmospheric attenuation of DNI has been studied with and without aerosols. In the presence of aerosols corresponding to 10 km visibility, the total solar DNI attenuation can reach about 84% in the UV domain, 56% in the visible domain and 35.08% in the rest of the infrared domain. The Geant4 results have been compared to those calculated by the MYSTIC code of LibRadtran package and the Beer-Lambert law under the same atmospheric conditions. The average relative transmittance difference between Geant4 and MYSTIC is of the order of few percent in the entire solar spectrum. In the case of atmosphere with aerosols corresponding to 23 km visibility, the most important average of the relative difference between Geant4 and MYSTIC transmittances is about 7.5% in the UV domain and stays between 1.19% and, 3.31% in the rest of the spectrum. More importantly, in this last case of the atmosphere, the values of the spectral transmittance of Geant4 remain intermediate between those of MYSTIC and Beer-Lambert law in the entire visible range up to 800 nm.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit
    Freudenberg, Robert
    Kotzerke, Jorg
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09): : 1488 - 1489
  • [2] Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
    Liu, R.
    Ji, Z.
    Cai, B.
    Hugo, G.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [3] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09): : 1489 - 1489
  • [4] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117
  • [5] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    [J]. NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [6] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [7] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Dae-Hyun Kim
    Young Nam Kang
    Tae-Suk Suh
    Jungwook Shin
    Jong Won Kim
    Seung Hoon Yoo
    Seyjoon Park
    Sang Hoon Lee
    Sungkoo Cho
    Dongho Shin
    Dae Yong Kim
    Se Byeong Lee
    [J]. Journal of the Korean Physical Society, 2012, 61 : 1125 - 1130
  • [8] Validation of Independent IMRT and VMAT Dose Calculation System based on Geant4 Monte Carlo Toolkit
    Choi, H. J.
    Park, H.
    Shin, W. G.
    Kim, J. I.
    Min, C. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S942
  • [9] Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit
    Incerti, S.
    Zhang, Q.
    Andersson, F.
    Moretto, Ph.
    Grime, G. W.
    Merchant, M. J.
    Nguyen, D. T.
    Habchi, C.
    Pouthier, T.
    Seznec, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 20 - 27
  • [10] Polarized electron Mott scattering model for the Geant4 Monte Carlo toolkit
    Dragowski, M.
    Adamus, M.
    Weber, G.
    Wlodarczyk, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 488 : 37 - 42