Density weighted turbo spin echo imaging

被引:4
|
作者
Zeller, Mario [1 ]
Gutberlet, Marcel [2 ]
Staeb, Daniel [1 ]
Ritter, Christian Oliver [1 ]
Beer, Meinrad [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ,3 ]
机构
[1] Univ Wurzburg, Inst Radiol, Univ Clin, D-97080 Wurzburg, Germany
[2] Hannover Med Sch, Dept Radiol, Hannover, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr CHFC, D-97080 Wurzburg, Germany
关键词
density weighting; variable density; turbo spin echo; spatial response function; modulation transfer function; SNR; RELAXATION-TIMES; MAGNETIC-FIELD; ACQUISITION; RARE; MR;
D O I
10.1002/jmri.23872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To optimize the spatial response function (SRF) while maintaining optimal signal to noise ratio (SNR) in T2 weighted turbo spin echo (TSE) imaging by prospective density weighting. Materials and Methods Density weighting optimizes the SRF by sampling the k-space with variable density without the need of retrospective filtering, which would typically result in nonoptimal SNR. For TSE, the T2 decay needs to be considered when calculating an optimized sampling pattern. Simulations were carried out and T2 weighted in vivo TSE measurements were performed on a 3 Tesla MRI system. To evaluate the SNR, reversed centric density weighted and retrospectively filtered Cartesian acquisitions with identical measurement parameters and SRFs were compared with TEeff = 90 ms and a density weighted k-space sampling optimized to yield a Kaiser function for SRF side lobe suppression for white matter. Results Density weighting of a reversed centric reordering scheme resulted in an SNR increase of (43 +/- 13)% compared with the Cartesian acquisition with retrospective filtering while maintaining comparable contrast behavior. Conclusion Density weighting is applicable to TSE imaging and results in significantly increased SNR. The gain can be used to shorten the measurement time, which suggests applying density weighting in both time and SNR constrained MRI. J. Magn. Reson. Imaging 2013;37:965973. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 50 条
  • [21] Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children
    Hauer, MP
    Uhl, M
    Allmann, HK
    Laubenberger, J
    Zimmerhackl, LB
    Langer, M
    PEDIATRIC RADIOLOGY, 1998, 28 (11) : 846 - 850
  • [22] Evaluating the Efficacy of Volume Isotropic Turbo Spin Echo Acquisition Versus T2-Weighted Turbo Spin Echo Imaging in the Diagnosis of Nerve Root and Perineuronal Pathologies in Spinal Disorders
    Sam, Ajina
    Jaypradha, S.
    Pandian, Vinoth
    Ramakrishnan, Karthik Krishna
    Natarajan, Paarthipan
    Muralidharan, Yuvaraj
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [23] Experimental O-Space Turbo Spin Echo Imaging
    Wang, Haifeng
    Tam, Leo
    Kopanoglu, Emre
    Peters, Dana C.
    Constable, R. Todd
    Galiana, Gigi
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1654 - 1661
  • [24] Diffusion-Weighted Imaging of the Macaque Brain Using Diffusion-Prepared Turbo Spin Echo in MRI
    Zhang, Jialu
    Zhang, Xiaotong
    APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [25] Accuracy of turbo spin-echo diffusion-weighted imaging signal intensity measurements for the diagnosis of cholesteatoma
    Ozgen, Bure
    Bulut, Elif
    Dolgun, Anil
    Bajin, Munir Demir
    Sennaroglu, Levent
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2017, 23 (04) : 300 - 306
  • [26] MR myelography using inversion recovery turbo spin echo technique: Comparison with heavily T2-weighted turbo spin echo technique
    Eun, CK
    Jeong, HW
    Lee, SJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 123 - 123
  • [27] Single-Shot Turbo Spin-Echo Diffusion-Weighted Imaging for Retinoblastoma: Initial Experience
    de Graaf, P.
    Pouwels, P. J. W.
    Rodjan, F.
    Moll, A. C.
    Imhof, S. M.
    Knol, D. L.
    Sanchez, E.
    van der Valk, P.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) : 110 - 118
  • [28] Optimal acceleration factor for image acquisition in turbo spin echo: diffusion-weighted imaging with compressed sensing
    Takashima, Hiroyuki
    Nakanishi, Mitsuhiro
    Imamura, Rui
    Akatsuka, Yoshihiro
    Nagahama, Hiroshi
    Ogon, Izaya
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (01) : 100 - 104
  • [29] Optimal acceleration factor for image acquisition in turbo spin echo: diffusion-weighted imaging with compressed sensing
    Hiroyuki Takashima
    Mitsuhiro Nakanishi
    Rui Imamura
    Yoshihiro Akatsuka
    Hiroshi Nagahama
    Izaya Ogon
    Radiological Physics and Technology, 2021, 14 : 100 - 104
  • [30] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212