Density weighted turbo spin echo imaging

被引:4
|
作者
Zeller, Mario [1 ]
Gutberlet, Marcel [2 ]
Staeb, Daniel [1 ]
Ritter, Christian Oliver [1 ]
Beer, Meinrad [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ,3 ]
机构
[1] Univ Wurzburg, Inst Radiol, Univ Clin, D-97080 Wurzburg, Germany
[2] Hannover Med Sch, Dept Radiol, Hannover, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr CHFC, D-97080 Wurzburg, Germany
关键词
density weighting; variable density; turbo spin echo; spatial response function; modulation transfer function; SNR; RELAXATION-TIMES; MAGNETIC-FIELD; ACQUISITION; RARE; MR;
D O I
10.1002/jmri.23872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To optimize the spatial response function (SRF) while maintaining optimal signal to noise ratio (SNR) in T2 weighted turbo spin echo (TSE) imaging by prospective density weighting. Materials and Methods Density weighting optimizes the SRF by sampling the k-space with variable density without the need of retrospective filtering, which would typically result in nonoptimal SNR. For TSE, the T2 decay needs to be considered when calculating an optimized sampling pattern. Simulations were carried out and T2 weighted in vivo TSE measurements were performed on a 3 Tesla MRI system. To evaluate the SNR, reversed centric density weighted and retrospectively filtered Cartesian acquisitions with identical measurement parameters and SRFs were compared with TEeff = 90 ms and a density weighted k-space sampling optimized to yield a Kaiser function for SRF side lobe suppression for white matter. Results Density weighting of a reversed centric reordering scheme resulted in an SNR increase of (43 +/- 13)% compared with the Cartesian acquisition with retrospective filtering while maintaining comparable contrast behavior. Conclusion Density weighting is applicable to TSE imaging and results in significantly increased SNR. The gain can be used to shorten the measurement time, which suggests applying density weighting in both time and SNR constrained MRI. J. Magn. Reson. Imaging 2013;37:965973. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 50 条
  • [31] Turbo Gradient and Spin Echo PROPELLER-Diffusion Weighted Imaging for Orbital Tumors: A Comparative Study With Readout-Segmented Echo-Planar Imaging
    Fu, Qing
    Kong, Xiang-chuang
    Liu, Ding-Xi
    Zhou, Kun
    Guo, Yi-hao
    Lei, Zi-Qiao
    Zheng, Chuan-sheng
    Yang, Fan
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [32] Turbo spin-echo diffusion-weighted MR of ischemic stroke
    Lovblad, KO
    Jakob, PM
    Chen, Q
    Baird, AE
    Schlaug, G
    Warach, S
    Edelman, RR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (02) : 201 - 208
  • [33] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772
  • [34] TRUE PROTON DENSITY AND T2-WEIGHTED TURBO SPIN-ECHO SEQUENCES FOR ROUTINE MRI OF THE BRAIN
    FELLNER, F
    SCHMITT, R
    TRENKLER, J
    FELLNER, C
    HELMBERGER, T
    OBLETTER, N
    BOHMJURKOVIC, H
    NEURORADIOLOGY, 1994, 36 (08) : 591 - 597
  • [35] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)
  • [36] MR imaging of the rotator cuff mechanism: Comparison of spin-echo and turbo spin-echo sequences
    Sonin, AH
    Peduto, AJ
    Fitzgerald, SW
    Callahan, CM
    Bresler, ME
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 333 - 338
  • [37] Comparison of conventional and turbo spin-echo T1-weighted MR imaging in acute knee trauma
    Eustace, S
    Hentzen, P
    Adams, J
    Harper, K
    Jara, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1393 - 1395
  • [38] Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: Initial experience
    Michaely, Henrik J.
    Kramer, Harald
    Weckbach, Sabine
    Dietrich, Olaf
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) : 148 - 153
  • [39] A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo
    Li, Z.
    Hu, H. H.
    Miller, J. H.
    Karis, J. P.
    Cornejo, P.
    Wang, D.
    Pipe, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 642 - 647
  • [40] Imaging of the degenerative spine using a sagittal T2-weighted DIXON turbo spin-echo sequence
    Sollmann, Nico
    Moench, Sebastian
    Riederer, Isabelle
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131