Density weighted turbo spin echo imaging

被引:4
|
作者
Zeller, Mario [1 ]
Gutberlet, Marcel [2 ]
Staeb, Daniel [1 ]
Ritter, Christian Oliver [1 ]
Beer, Meinrad [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ,3 ]
机构
[1] Univ Wurzburg, Inst Radiol, Univ Clin, D-97080 Wurzburg, Germany
[2] Hannover Med Sch, Dept Radiol, Hannover, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr CHFC, D-97080 Wurzburg, Germany
关键词
density weighting; variable density; turbo spin echo; spatial response function; modulation transfer function; SNR; RELAXATION-TIMES; MAGNETIC-FIELD; ACQUISITION; RARE; MR;
D O I
10.1002/jmri.23872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To optimize the spatial response function (SRF) while maintaining optimal signal to noise ratio (SNR) in T2 weighted turbo spin echo (TSE) imaging by prospective density weighting. Materials and Methods Density weighting optimizes the SRF by sampling the k-space with variable density without the need of retrospective filtering, which would typically result in nonoptimal SNR. For TSE, the T2 decay needs to be considered when calculating an optimized sampling pattern. Simulations were carried out and T2 weighted in vivo TSE measurements were performed on a 3 Tesla MRI system. To evaluate the SNR, reversed centric density weighted and retrospectively filtered Cartesian acquisitions with identical measurement parameters and SRFs were compared with TEeff = 90 ms and a density weighted k-space sampling optimized to yield a Kaiser function for SRF side lobe suppression for white matter. Results Density weighting of a reversed centric reordering scheme resulted in an SNR increase of (43 +/- 13)% compared with the Cartesian acquisition with retrospective filtering while maintaining comparable contrast behavior. Conclusion Density weighting is applicable to TSE imaging and results in significantly increased SNR. The gain can be used to shorten the measurement time, which suggests applying density weighting in both time and SNR constrained MRI. J. Magn. Reson. Imaging 2013;37:965973. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 50 条
  • [41] Simple method for whole-brain volumetric T1-weighted turbo spin-echo imaging
    Yoneyama M.
    Nakamura M.
    Obara M.
    Namiki T.
    Takemura A.
    Tatsuno S.
    Sawano S.
    Radiological Physics and Technology, 2014, 7 (1) : 167 - 175
  • [42] Axial Black Blood Turbo Spin Echo Imaging of the Right Ventricle
    Berkowitz, Seth J.
    Macedo, Robson
    Malayeri, Ashkan A.
    Shea, Steven M.
    Lorenz, Christine H.
    Calkins, Hugh
    Vogel-Claussen, Jens
    Tandri, Harikrishna
    Bluemke, David A.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 307 - 314
  • [43] Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee
    Bamidele F. Kammen
    Eric M. Padua
    S. Pinar Karakas
    R. Ward Hagar
    Dave M. Hitt
    Nirav K. Pandya
    Taylor Chung
    Pediatric Radiology, 2019, 49 : 791 - 800
  • [44] Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee
    Kammen, Bamidele F.
    Padua, Eric M.
    Karakas, S. Pinar
    Hagar, R. Ward
    Hitt, Dave M.
    Pandya, Nirav K.
    Chung, Taylor
    PEDIATRIC RADIOLOGY, 2019, 49 (06) : 791 - 800
  • [45] T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging
    Dohan, Anthony
    Gavini, Jean-Philippe
    Place, Vinciane
    Sebbag, Delphine
    Vignaud, Alexandre
    Herbin, Christine
    Hamzi, Lounis
    Boudiaf, Mourad
    Soyer, Philippe
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E655 - E661
  • [46] Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
    Panyarak, Wannakamon
    Chikui, Toru
    Yamashita, Yasuo
    Kamitani, Takeshi
    Yoshiura, Kazunori
    ACADEMIC RADIOLOGY, 2019, 26 (10) : E305 - E316
  • [47] Imaging of heterogeneous materials with a turbo spin echo single-point imaging technique
    Beyea, SD
    Balcom, BJ
    Mastikhin, IV
    Bremner, TW
    Armstrong, RL
    Grattan-Bellew, PE
    JOURNAL OF MAGNETIC RESONANCE, 2000, 144 (02) : 255 - 265
  • [48] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [49] COMPARISON OF RESPIRATORY-TRIGGERED T2-WEIGHTED TURBO SPIN-ECHO IMAGING VERSUS BREATH-HOLD T2-WEIGHTED TURBO SPIN-ECHO IMAGING: DISTINGUISHING BENIGN FROM MALIGNANT LIVER LESIONS IN PATIENTS WITH COLORECTAL CANCER
    Coenegrachts, K.
    ter Beek, L.
    Haspeslagh, M.
    Bipat, S.
    Stoker, J.
    Rigauts, H.
    JBR-BTR, 2009, 92 (04): : 195 - 201
  • [50] Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study
    Yoshida, Tsukasa
    Urikura, Atsushi
    Shirata, Kensei
    Nakaya, Yoshihiro
    Terashima, Shingo
    Hosokawa, Yoichiro
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1065):