Amperometric biosensor for urea

被引:0
|
作者
Ha, KS
Seo, ML
机构
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An enzyme electrode for the amperometric measurement of urea was prepared by co-immobilizing L-glutamate dehydrogenase and urease onto an Immobilon-AV affinity membrane attached to a glassy carbon electrode. The reduced nicotinamide adenine dinucleotide(NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. The enzyme-immobilized electrode was linear over the range of 2.0 x 10(-5) to 2 x 10(-4) M. The response time of the electrode was approximately 3 min. and the optimum pH of the enzyme immobilized membrane was pH 7.4-7.6 (Dulbcco's buffer solution). It was stable for at least two weeks or 50 assays. There was no interference from other physiological species, except from high levels of ascorbic acid.
引用
收藏
页码:1149 / 1152
页数:4
相关论文
共 50 条
  • [41] Development of novel amperometric urea biosensor based on Fc-PAMAM and MWCNT bio-nanocomposite film
    Dervisevic, Esma
    Dervisevic, Muamer
    Nyangwebah, Jackson Narkpa
    Senel, Mehmet
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 920 - 926
  • [42] Amperometric urea biosensor based on urease and electropolymerized toluidine blue dye as a pH-sensitive redox probe
    Vostiar, I
    Tkac, J
    Sturdik, E
    Gemeiner, P
    BIOELECTROCHEMISTRY, 2002, 56 (1-2) : 113 - 115
  • [43] An amperometric urea biosensor based on covalently immobilized urease on an electrode made of hyperbranched polyester functionalized gold nanoparticles
    Tiwari, Ashutosh
    Aryal, Santosh
    Pilla, Srikanth
    Gong, Shaoqin
    TALANTA, 2009, 78 (4-5) : 1401 - 1407
  • [44] The fabrication and optimization of the disposable amperometric biosensor
    Tu, YF
    Fu, ZQ
    Chen, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (02) : 101 - 105
  • [45] Amperometric creatinine biosensor for hemodialysis patients
    Tombach, B
    Schneider, J
    Matzkies, F
    Schaefer, RM
    Chemnitius, GC
    CLINICA CHIMICA ACTA, 2001, 312 (1-2) : 129 - 134
  • [46] Amperometric biosensor for rapid determination of alanine
    Kwan, RCH
    Hon, PYT
    Renneberg, R
    ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 81 - 88
  • [47] AMPEROMETRIC DETERMINATION OF PHOSPHATE IONS BY BIOSENSOR
    KULYS, J
    HIGGINS, IJ
    BANNISTER, JV
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 187 - 191
  • [48] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF ETHANOL VAPOR
    PARK, JK
    YEE, HJ
    KIM, ST
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7): : 587 - 594
  • [49] Design an Amperometric Biosensor for the Detection of Lactate
    Mancilla-Pena, Fernando
    Reyes-Gomez, Juan
    Garcia-De La Rosa, Luis A.
    Flores-Alvarez, Juan M.
    Martinez-Orozco, Reinaldo D.
    Paramo-Garcia, Ulises
    MOROCCAN JOURNAL OF CHEMISTRY, 2018, 6 (03): : 540 - 547
  • [50] Activity Measurement of Chitosanase by an Amperometric Biosensor
    Tatsumi, Hirosuke
    Katano, Hajime
    Ikeda, Tokuji
    Kimoto, Hisashi
    ANALYTICAL SCIENCES, 2009, 25 (06) : 825 - 827