Amperometric urea biosensor based on urease and electropolymerized toluidine blue dye as a pH-sensitive redox probe

被引:85
|
作者
Vostiar, I
Tkac, J
Sturdik, E
Gemeiner, P
机构
[1] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Dept Biochem Technol, SK-81237 Bratislava, Slovakia
[2] Slovak Acad Sci, Inst Chem, SK-84238 Bratislava, Slovakia
关键词
amperometric pH sensing; biosensor; polytoluidine blue; urease;
D O I
10.1016/S1567-5394(02)00042-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The electropolymerized toluidine blue film deposited on the glassy carbon electrode show amperometrically detectable pH sensitivity. This feature of polytoluidine blue (PTOB) film was used for a construction of an amperometric urea biosensor. We have observed a linear shift of the formal redox potential with increasing pH value between 4 and 8 giving the slope of 81 mV(Delta) pH(-1). Polytoluidine blue film has had a significantly increased stability and higher electrochemical activity compared to the adsorbed monomeric dye. The polytoluidine blue urea biosensor has been operating at a working potential of -200 mV vs. SCE. The sensitivity of the biosensor was 980 nA mM(-1) cm(-2). The biosensor showed linearity in concentration range up to 0.8 mM with the detection limit of 0.02 mM (S/N = 3). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:113 / 115
页数:3
相关论文
共 50 条
  • [1] Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator
    Pizzariello, A
    Stredansky, M
    Stredanská, S
    Miertus, S
    TALANTA, 2001, 54 (04) : 763 - 772
  • [2] Biological sensor for urea by using electropolymerized pH-sensitive polymer
    Komaba, S
    Seyama, M
    Fujino, Y
    Osaka, T
    Satoh, I
    PROCEEDINGS OF THE SYMPOSIUM ON CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL ELECTROCHEMICAL METHODS, 1997, 97 (19): : 882 - 888
  • [3] Amperometric bienzyme glucose biosensor based on carbon nanotube modified electrode with electropolymerized poly(toluidine blue O) film
    Wang, Wenju
    Wang, Fang
    Yao, Yanli
    Hu, Shengshui
    Shiu, Kwok-Keung
    ELECTROCHIMICA ACTA, 2010, 55 (23) : 7055 - 7060
  • [4] A pH-sensitive channel regulates urea access to Helicobacter pylori urease
    Gordon, D
    GASTROENTEROLOGY, 2000, 118 (02) : 249 - 249
  • [5] pH-Sensitive Oscillatory Motion of a Urease Motor on the Urea Aqueous Phase
    Xu, Yu
    Ji, Lin
    Izumi, Shunsuke
    Nakata, Satoshi
    CHEMISTRY-AN ASIAN JOURNAL, 2021, 16 (13) : 1762 - 1766
  • [6] pH-Sensitive gold nanoclusters: preparation and analytical applications for urea, urease, and urease inhibitor detection
    Deng, Hao-Hua
    Wu, Gang-Wei
    Zou, Zhi-Qiang
    Peng, Hua-Ping
    Liu, Ai-Lin
    Lin, Xin-Hua
    Xia, Xing-Hua
    Chen, Wei
    CHEMICAL COMMUNICATIONS, 2015, 51 (37) : 7847 - 7850
  • [7] Urea detection in milk by urease-assisted pH-sensitive carbon dots
    Yin, Wenzhi
    Zhang, Ye
    Gu, Jiao
    Wang, Tingyu
    Ma, Chaoqun
    Zhu, Chun
    Li, Lei
    Yang, Zichen
    Zhu, Tuo
    Chen, Guoqing
    APPLIED OPTICS, 2021, 60 (33) : 10421 - 10428
  • [8] Electropolymerized poly(Toluidine Blue)-modified carbon felt for highly sensitive amperometric determination of NADH in flow injection analysis
    Hasebe, Yasushi
    Wang, Yue
    Fukuoka, Kazuya
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2011, 23 (06) : 1050 - 1056
  • [9] An rGQD/chitosan nanocomposite-based pH-sensitive probe: application to sensing in urease activity assays
    Shi, Fanping
    Shang, Danyi
    Wang, Zonghua
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (34) : 13398 - 13407