Amperometric biosensor for urea

被引:0
|
作者
Ha, KS
Seo, ML
机构
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An enzyme electrode for the amperometric measurement of urea was prepared by co-immobilizing L-glutamate dehydrogenase and urease onto an Immobilon-AV affinity membrane attached to a glassy carbon electrode. The reduced nicotinamide adenine dinucleotide(NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. The enzyme-immobilized electrode was linear over the range of 2.0 x 10(-5) to 2 x 10(-4) M. The response time of the electrode was approximately 3 min. and the optimum pH of the enzyme immobilized membrane was pH 7.4-7.6 (Dulbcco's buffer solution). It was stable for at least two weeks or 50 assays. There was no interference from other physiological species, except from high levels of ascorbic acid.
引用
收藏
页码:1149 / 1152
页数:4
相关论文
共 50 条
  • [21] Amperometric glyceride biosensor
    Laurinavicius, V
    Kurtinaitiene, B
    Gureviciene, V
    Boguslavsky, L
    Geng, L
    Skotheim, T
    ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 159 - 166
  • [22] Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    Adeloju, S. B.
    Shaw, S. J.
    Wallace, G. G.
    Analytica Chimica Acta, 341 (2-3):
  • [23] Amperometric urea biosensor based on immobilized urease on polypyrrole and macroporous polypyrrole modified Pt electrode
    Hosseinian, Maliheh
    Najafpour, Ghasem
    Rahimpour, Ahmad
    TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1063 - 1074
  • [24] Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) : 155 - 160
  • [25] Development of Amperometric Biosensor Immobilized by Entrapment of Urease Enzyme in Polypiroll Film for the Determination of Blood Urea
    Busono, Pratondo
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS, 2015, : 123 - 126
  • [26] Thermoresponsive amperometric glucose biosensor
    Pinyou, Piyanut
    Ruff, Adrian
    Poeller, Sascha
    Barwe, Stefan
    Nebel, Michaela
    Alburquerque, Natalia Guerrero
    Wischerhoff, Erik
    Laschewsky, Andre
    Schmaderer, Sebastian
    Szeponik, Jan
    Plumere, Nicolas
    Schuhmann, Wolfgang
    BIOINTERPHASES, 2016, 11 (01) : 1 - 7
  • [27] Development of an amperometric biosensor for lactate
    Lillis, B
    Grogan, C
    Berney, H
    Lane, B
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 394 - 399
  • [28] Amperometric biosensor for the determination of creatine
    A. Ramanavicius
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1899 - 1906
  • [29] A microflow amperometric glucose biosensor
    Towe, Bruce C.
    Pizziconi, Vincent B.
    Biosensors and Bioelectronics, 1997, 12 (9-10): : 893 - 899
  • [30] A microflow amperometric glucose biosensor
    Towe, BC
    Pizziconi, VB
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10): : 893 - 899