Amperometric biosensor for urea

被引:0
|
作者
Ha, KS
Seo, ML
机构
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An enzyme electrode for the amperometric measurement of urea was prepared by co-immobilizing L-glutamate dehydrogenase and urease onto an Immobilon-AV affinity membrane attached to a glassy carbon electrode. The reduced nicotinamide adenine dinucleotide(NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. The enzyme-immobilized electrode was linear over the range of 2.0 x 10(-5) to 2 x 10(-4) M. The response time of the electrode was approximately 3 min. and the optimum pH of the enzyme immobilized membrane was pH 7.4-7.6 (Dulbcco's buffer solution). It was stable for at least two weeks or 50 assays. There was no interference from other physiological species, except from high levels of ascorbic acid.
引用
收藏
页码:1149 / 1152
页数:4
相关论文
共 50 条
  • [31] AMPEROMETRIC BIOSENSOR FOR GLUCOSE AND LACTATE
    KAISHEVA, A
    ATANASOV, P
    GAMBURZEV, S
    DIMCHEVA, N
    ILIEV, I
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (01) : 53 - 57
  • [32] Amperometric Biosensor for Phenol Determination
    da Costa Silva, Livia Maria
    Salgado, Andrea Medeiros
    Zarur Coelho, Maria Alice
    ICHEAP-10: 10TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2011, 24 : 1249 - +
  • [33] Atn amperometric glucose biosensor
    Podaru, C
    Bostan, C
    Malide, C
    Neagoe, O
    Simion, M
    Popescu, G
    Garganciuc, D
    Tzetcu, N
    CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 101 - 104
  • [34] Amperometric biosensor for the determination of creatine
    Ramanavicius, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1899 - 1906
  • [35] Rutin determination at an amperometric biosensor
    Mousty, Christine
    Cosnier, Serge
    Lopez, Marta Sanchez-Paniagua
    Lopez-Cabarcos, Enrique
    Lopez-Ruiz, Beatriz
    ELECTROANALYSIS, 2007, 19 (2-3) : 253 - 258
  • [36] A POLISHABLE AMPEROMETRIC BIOSENSOR FOR BILIRUBIN
    WANG, J
    OZSOZ, M
    ELECTROANALYSIS, 1990, 2 (08) : 647 - 650
  • [37] Amperometric urea biosensor based on covalently immobilized urease on an electrochemically polymerized film of polyaniline containing MWCNTs
    Meibodi, Azam S. Emami
    Haghjoo, Sara
    SYNTHETIC METALS, 2014, 194 : 1 - 6
  • [38] Inhibitive determination of Hg2+ ion by an amperometric urea biosensor using poly(vinylferrocenium) film
    Kuralay, Filiz
    Ozyoruk, Haluk
    Yildiz, Attila
    ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (05) : 1156 - 1159
  • [39] Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator
    Pizzariello, A
    Stredansky, M
    Stredanská, S
    Miertus, S
    TALANTA, 2001, 54 (04) : 763 - 772
  • [40] A NOVEL AMPEROMETRIC UREA SENSOR
    OSAKAI, T
    KAKUTANI, T
    SENDA, M
    ANALYTICAL SCIENCES, 1988, 4 (05) : 529 - 530