On-Line Partial Discharge Monitoring System for Power Transformers Based on the Simultaneous Detection of High Frequency, Ultra-High Frequency, and Acoustic Emission Signals

被引:24
|
作者
Sikorski, Wojciech [1 ]
Walczak, Krzysztof [1 ]
Gil, Wieslaw [2 ]
Szymczak, Cyprian [1 ]
机构
[1] Poznan Univ Tech, Inst Elect Power Engn, PL-60965 Poznan, Poland
[2] Mikronika, PL-60001 Poznan, Poland
关键词
power transformer; partial discharge (PD); on-line PD monitoring system; active dielectric window; acoustic emission; UHF antenna; PIFA; HFCT sensor; UHF SENSORS; FRACTAL ANTENNA; BAND ANTENNA; PIFA; BIOTELEMETRY; BANDWIDTH; CELLULOSE; LOCATION; DESIGN; TRENDS;
D O I
10.3390/en13123271
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The article presents a novel on-line partial discharge (PD) monitoring system for power transformers, whose functioning is based on the simultaneous use of three unconventional methods of PD detection: high-frequency (HF), ultra-high frequency (UHF), and acoustic emission (AE). It is the first monitoring system equipped in an active dielectric window (ADW), which is a combined ultrasonic and electromagnetic PD sensor. The article discusses in detail the process of designing and building individual modules of hardware and software layers of the system, wherein the most attention was paid to the PD sensors, i.e., meandered planar inverted-F antenna (MPIFA), high-frequency current transformer (HFCT), and active dielectric window with ultrasonic transducer, which were optimized for detection of PDs occurring in oil-paper insulation. The prototype of the hybrid monitoring system was first checked on a 330 MVA large power transformer during the induced voltage test with partial discharge measurement (IVPD). Next, it was installed on a 31.5 MVA substation power transformer and integrated according to the standard IEC 61850 with SCADA (Supervisory Control and Data Acquisition) system registering voltage, active power, and oil temperature of the monitored unit. The obtained results showed high sensitivity of the manufactured PD sensors as well as the advantages of the simultaneous use of three techniques of PD detection and the possibility of discharge parameter correlation with other power transformer parameters.
引用
下载
收藏
页数:37
相关论文
共 50 条
  • [41] New ultra high frequency sensor for detection of partial discharge for GIS
    Hu, Di-Jun
    Chen, Jie-Hua
    Li, Zhong
    Feng, Yun-Ping
    Gaoya Dianqi/High Voltage Apparatus, 2003, 39 (04):
  • [42] An Accurate and Efficient Time Delay Estimation Method of Ultra-High Frequency Signals for Partial Discharge Localization in Substations
    Li, Pengfei
    Dai, Kejie
    Zhang, Tong
    Jin, Yantao
    Liu, Yushun
    Liao, Yuan
    SENSORS, 2018, 18 (10)
  • [43] Multi-scale grid dimension extraction and recognition of ultra-high frequency signals of transformer partial discharge
    Li, Jian
    Wang, Xiao-Wei
    Jin, Zhuo-Rui
    Sun, Cai-Xin
    Cheng, Chang-Kui
    Dianwang Jishu/Power System Technology, 2010, 34 (02): : 159 - 163
  • [44] Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor
    Shin, Jong-Yeol
    Lee, Young-Sang
    Hong, Jin-Woong
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2013, 14 (04) : 211 - 215
  • [45] An On-line Monitoring System for Partial Discharge from High Voltage Transformer
    王哲
    陈学允
    蔡惟铮
    Journal of Harbin Institute of Technology(New series), 1998, (02) : 52 - 56
  • [46] High capacity motors on-line diagnosis based on ultra wide band partial discharge detection
    Carvajal, A
    Garcia-Colon, VR
    IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES, PROCEEDINGS, 2003, : 168 - 170
  • [47] Study of on-line monitoring method of partial discharge for power transformers based on RFCT and microstrip antenna
    Cheng, YH
    Chen, Y
    Liu, T
    Xu, XW
    Ji, LL
    Chen, W
    Chen, LX
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE, 2005, : 103 - 107
  • [48] Calibration of Ultra-High Frequency (UHF) Partial Discharge Sensors Using FDTD Method
    Ishak, Asnor Mauan
    Ishak, Mohd Taufiq
    INTERNATIONAL CONFERENCE ON ENGINEERING AND TECHNOLOGY (INTCET 2017), 2018, 1930
  • [49] A new microstrip antenna used for detecting the ultra-high frequency signal caused by the partial discharge in power equipments
    Wang, Youyuan
    Wu, Junfeng
    Xu, Haiying
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (10): : 136 - 144
  • [50] Ultra-high frequency sensors positioning on the power transformer to mitigate the negative effects on the partial discharge localization accuracy
    Jangjoo, Mohammad Amin
    Allahbakhshi, Mehdi
    Mirzaei, Hassan Reza