摘要
Introduction: Minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur appears to be a dangerous procedure due to possible femoral artery injury. Objective: This study aims to determine the feasibility of applying MIPO of the femur via the medial approach, and to determine the anatomical relationship and structures at risk between the artery and the implant using computed tomography angiography. Materials and methods: A descriptive study of ten fresh cadavers was done. Two separate incisions were made, creating a submuscular tunnel close to the medial side of the femur. An 11- or 13-hole LCP lateral proximal tibial plate (5.0 mm) was inserted through the distal incision into the submuscular tunnel and fixed. A CT angiogram with 3D reconstruction was made to determine the distance from and location of the plate relative to the femoral artery and surgical dissection was done to identify the structures at risk. Results: No disruptions of superficial or deep femoral arteries were found. The closest distances from the superficial femoral artery and deep femoral artery to the plate were 8.3-27.2 mm (average 16.3 mm) (99% CI: 12.7-19.9) at the level 3 and 4.5-20.0 mm (average 8.6 mm) (99% CI: 6.4-10.9) at the level 2 in the proximal part of femur, respectively. The location where the SFA crossed the anterior cortex of the femur in the sagittal plane was 9.7-36.0% of the femoral length (average 20.1%) (99% CI: 15.0-25.3%) and the posterior cortex of the femur was 24.7-55.3% of the femoral length (average 40.8%) (99% CI: 35.0-46.7%). The location where the DFA crossed the anterior cortex of the femur in the sagittal plane was 7.9-25.3% of the femoral length (average 13.4%) (99% CI: 10.6-16.3%) and where it crossed the posterior cortex of the femur was 21.7-39.4% of the femoral length (average 31.2%) (99% CI: 27.1-33.3%). Conclusion: MIPO of the femur via medial approach is a feasible option for treatment of femoral fractures when the lateral approach is contraindicated. The distal 60% of the femoral length is safe for this approach. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2170 / 2176
页数:7
相关论文
共 50 条
  • [31] Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study
    Farouk, O
    Krettek, C
    Miclau, T
    Schandelmaier, P
    Guy, P
    Tscherne, H
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 : SA7 - SA12
  • [32] The Risk of Neurovascular Injury in Minimally Invasive Plate Osteosynthesis (MIPO) when Using a Distal Tibia Anterolateral Plate: A Cadaver Study
    Lidder, S.
    Masterson, S.
    Grechenig, C.
    Clement, H.
    Gaensslen, A.
    Grechenig, S.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2014, 81 (05) : 313 - 316
  • [33] Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures
    Kundangar R.S.
    Mohanty S.P.
    Bhat N.S.
    MUSCULOSKELETAL SURGERY, 2019, 103 (2) : 191 - 197
  • [34] MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS (MIPO) IN HUMERAL SHAFT FRACTURES - BIOMECHANICS - DESIGN - CLINICAL RESULTS
    Sanjeevaiah
    Reddy, Praneeth
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (54): : 9449 - 9456
  • [35] Outcome of Locking Compression Plate in Supracondylar Fracture of Distal Femur by Minimally Invasive Plate Osteosynthesis
    Malik, Adnan Latif
    Siddique, Mudassar
    Niazi, Noman Shakeel
    Niazi, Suhail Niaz Khan
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 31 - 33
  • [36] Minimally Invasive Plate Osteosynthesis (MIPO) for Treatment of Delayed or Nonunion of the Humerus Shaft Fracture: A New Technique
    Okhovatpour, Mohammad Ali
    Yousefi-Hajivand, Esmaeel
    Khojasteh, Arash
    Tabrizi, Ali
    Mirahmadi, Alireza
    TRAUMA MONTHLY, 2022, 27 (02) : 445 - 452
  • [37] Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study
    Saengsin, Jirawat
    Vaseenon, Tanawat
    Pattamapaspong, Nuttaya
    Kritsaneephaiboon, Apipop
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (08): : 1758 - 1763
  • [38] Medial minimally invasive plate osteosynthesis for humeral shaft fractures: a case series
    Liu, Da-Peng
    Liang, Jing-Hao
    ANNALS OF MEDICINE AND SURGERY, 2023, 85 (06): : 3171 - 3178
  • [39] Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    Apivatthakakul, T.
    Chiewcharntanakit, S.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1119 - 1126
  • [40] Outcomes following minimally invasive plate osteosynthesis (MIPO) application in tibial pilon fractures - A systematic review
    Sourougeon, Yosef
    Barzilai, Yuval
    Haba, Yahav
    Spector, Barak
    Prat, Dan
    FOOT AND ANKLE SURGERY, 2023, 29 (08) : 566 - 575