The safety and feasibility of minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur: A cadaveric injection study

被引:46
|
作者
Jiamton, C. [1 ]
Apivatthakakul, T. [2 ,3 ]
机构
[1] Lerdsin Gen Hosp, Inst Orthopaed, Bangkok, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Orthoped, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Excellence Ctr, ORTC, Chiang Mai 50200, Thailand
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 11期
关键词
Femoral fracture; Minimally invasive plate osteosynthesis (MIPO); Medial approach; Femoral artery; DISTAL FEMUR; INTERNAL-FIXATION; FEMORAL FRACTURES; OSTEOTOMY; IMPLANT;
D O I
10.1016/j.injury.2015.08.032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur appears to be a dangerous procedure due to possible femoral artery injury. Objective: This study aims to determine the feasibility of applying MIPO of the femur via the medial approach, and to determine the anatomical relationship and structures at risk between the artery and the implant using computed tomography angiography. Materials and methods: A descriptive study of ten fresh cadavers was done. Two separate incisions were made, creating a submuscular tunnel close to the medial side of the femur. An 11- or 13-hole LCP lateral proximal tibial plate (5.0 mm) was inserted through the distal incision into the submuscular tunnel and fixed. A CT angiogram with 3D reconstruction was made to determine the distance from and location of the plate relative to the femoral artery and surgical dissection was done to identify the structures at risk. Results: No disruptions of superficial or deep femoral arteries were found. The closest distances from the superficial femoral artery and deep femoral artery to the plate were 8.3-27.2 mm (average 16.3 mm) (99% CI: 12.7-19.9) at the level 3 and 4.5-20.0 mm (average 8.6 mm) (99% CI: 6.4-10.9) at the level 2 in the proximal part of femur, respectively. The location where the SFA crossed the anterior cortex of the femur in the sagittal plane was 9.7-36.0% of the femoral length (average 20.1%) (99% CI: 15.0-25.3%) and the posterior cortex of the femur was 24.7-55.3% of the femoral length (average 40.8%) (99% CI: 35.0-46.7%). The location where the DFA crossed the anterior cortex of the femur in the sagittal plane was 7.9-25.3% of the femoral length (average 13.4%) (99% CI: 10.6-16.3%) and where it crossed the posterior cortex of the femur was 21.7-39.4% of the femoral length (average 31.2%) (99% CI: 27.1-33.3%). Conclusion: MIPO of the femur via medial approach is a feasible option for treatment of femoral fractures when the lateral approach is contraindicated. The distal 60% of the femoral length is safe for this approach. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2170 / 2176
页数:7
相关论文
共 50 条
  • [21] Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach
    Gupta, P.
    Tiwari, A.
    Thora, A.
    Gandhi, J. K.
    Jog, V. P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2016, 10 (01) : 29 - 37
  • [22] Clinical and radiographic evaluation of minimally invasive plate osteosynthesis (MIPO) in dogs with tibial fractures
    Istim, Cansu
    Arican, Mustafa
    VETERINARNI MEDICINA, 2022, 67 (06) : 316 - 322
  • [23] Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Tibial Fracture Using a Posterolateral Approach
    Kritsaneephaiboon, Apipop
    Tangtrakulwanich, Boonsin
    Dissaneewate, Pornpanit
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2015, 14 (03): : 139 - 145
  • [24] Minimally Invasive Plate Osteosynthesis (MIPO) of Comminuted Radial Fractures Using a Locking Plate Contoured on a 3D-Printed Model of the Feline Antebrachium: A Cadaveric Study
    Trebacz, Piotr
    Frymus, Jan
    Pawlik, Mateusz
    Barteczko, Anna
    Kurkowska, Aleksandra
    Czopowicz, Michal
    ANIMALS, 2024, 14 (09):
  • [25] Femoral fractures treated by minimally invasive plate osteosynthesis (MIPO) in patients with abdominal injuries
    Cicvaric, T.
    Stalekar, H.
    Ekl, D.
    Sustic, A.
    Marinovic, M.
    PROCEEDINGS OF THE 7TH EUROPEAN TRAUMA CONGRESS, 2006, : 93 - +
  • [26] RADIOLOGICAL AND FUNCTIONAL OUTCOME OF MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS (MIPO) IN CLOSED FRACTURES OF TIBIA
    Ullah, Naeem
    Mian, Amjad Ali
    Bukhari, Syed Imran
    Shah, Faaiz Ali
    GOMAL JOURNAL OF MEDICAL SCIENCES, 2024, 22 (03): : 208 - 212
  • [27] Radiological assessment of the safe zone for medial minimally invasive plate osteosynthesis in the distal femur with computed tomography angiography
    Kim, Jung Jae
    Oh, Hyoung Keun
    Bae, Joo-Yul
    Kim, Ji Wan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 1964 - 1969
  • [28] The safety and feasibility of a less invasive distal femur closing wedge osteotomy technique: a cadaveric dissection study of the medial aspect of the distal femur
    Visser, J.
    Brinkman, J. -M.
    Bleys, R. L. A. W.
    Castelein, R. M.
    van Heerwaarden, R. J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (01) : 220 - 227
  • [29] The safety and feasibility of a less invasive distal femur closing wedge osteotomy technique: a cadaveric dissection study of the medial aspect of the distal femur
    J. Visser
    J. -M. Brinkman
    R. L. A. W. Bleys
    R. M. Castelein
    R. J. van Heerwaarden
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 220 - 227
  • [30] Medial Knee Approach: An Anatomical Study of Minimally Invasive Plate Osteosynthesis in Medial Femoral Condylar Fracture
    Sirisreetreerux, Norachart
    Shafiq, Babar
    Osgood, Greg M.
    Hasenboehler, Erik A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : e357 - e361